Purpose/objective: Stereotactic radiosurgery of brain metastases requires highly conformal dose distributions. Besides beams setup, characteristics of the linear accelerator collimator may also play a role. In this study we compared the impact of leaf width on the dose outside the target for stereotactic radiosurgery of single brain metastases. Results: The mean dose was evaluated in the first 2 rings of 5 mm around the PTV(table 1). The difference in mean dose for the small lesions(Dpres=24 Gy) of the first ring of 5 mm is 1.8 Gy in favor of the Agility and 0.9 Gy for the larger lesions(Dpres=18 Gy)also in favor of the Agility. The difference is smaller for the larger lesions (figure1). Also for the second ring of 5 mm, adjacent to the first ring, the difference is is 1.1 Gy vs 0.8 Gy also in favor of the Agility. Conclusion: For the small lesions with a volume smaller than 4 cm³ the Agility shows a steeper gradient in the two surrounding rings than the MLCi1. Therefore we recommend the use of the Agility for treating the smaller lesions.
DOCUMENT
Het veranderende klimaat is vooral in binnensteden zichtbaar door de hoge mate van verstening die hier te vinden is. Juist op deze plekken zijn er weinig oplossingen voor hittestress en wateroverlast mogelijk, omdat de ruimte boven en onder de grond vaak beperkt is. In dit onderzoek werkten de Hanzehogeschool en The Leaf vof in een consortium met ondernemers en publieke organisaties aan het ontwikkelen van een oplossing voor deze problemen: de Leaf. Een ‘Leaf’ is een groene pergola die meerdere thema’s als hittestress, wateroverlast, biodiversiteit en circulariteit combineert in één oplossing. Het primaire doel van dit onderzoek was om de effectiviteit, haalbaarheid en rendabiliteit van een Leaf in de praktijk te toetsen. Daarvoor is een design thinking aanpak gevolgd, waarin verschillende methoden zijn gebruikt om onderzoeks- en ontwerpstappen te doorlopen. De uiteindelijke ontwerpen zijn uitgewerkt in fysieke prototypes met verschillende karakteristieken die vervolgens op hun effectiviteit zijn getest en vergeleken. Het onderzoek is met een interdisciplinair team van studenten en onderzoekers uitgevoerd, met ondersteuning van verschillende experts uit de praktijk.
MULTIFILE
In pre-treatment dose verification, low resolution detector systems are unable to identify shifts of individual leafs of high resolution multi leaf collimator (MLC) systems from detected changes in the dose deposition. The goal of this study was to introduce an alternative approach (the shutter technique) combined with a previous described iterative reconstruction method to accurately reconstruct high resolution MLC leaf positions based on low resolution measurements. For the shutter technique, two additional radiotherapy treatment plans (RT-plans) were generated in addition to the original RT-plan; one with even MLC leafs closed for reconstructing uneven leaf positions and one with uneven MLC leafs closed for reconstructing even leaf positions. Reconstructed leaf positions were then implemented in the original RT-plan for 3D dose reconstruction. The shutter technique was evaluated for a 6 MV Elekta SLi linac with 5 mm MLC leafs (Agility(™)) in combination with the MatriXX Evolution detector with detector spacing of 7.62 mm. Dose reconstruction was performed with the COMPASS system (v2.0). The measurement setup allowed one row of ionization chambers to be affected by two adjacent leaf pairs. Measurements were obtained for various field sizes with MLC leaf position errors ranging from 1.0 mm to 10.0 mm. Furthermore, one clinical head and neck IMRT treatment beam with MLC introduced leaf position errors of 5.0 mm was evaluated to illustrate the impact of the shutter technique on 3D dose reconstruction. Without the shutter technique, MLC leaf position reconstruction showed reconstruction errors up to 6.0 mm. Introduction of the shutter technique allowed MLC leaf position reconstruction for the majority of leafs with sub-millimeter accuracy resulting in a reduction of dose reconstruction errors. The shutter technique in combination with the iterative reconstruction method allows high resolution MLC leaf position reconstruction using low resolution measurements with sub-millimeter accuracy.
DOCUMENT
Plant photosynthesis and biomass production are associated with the amount of intercepted light, especially the light distribution inside the canopy. Three virtual canopies (n = 80, 3.25 plants/m2) were constructed based on average leaf size of the digitized plant structures: ‘small leaf’ (98.1 cm2), ‘medium leaf’ (163.0 cm2) and ‘big leaf’ (241.6 cm2). The ratios of diffuse light were set in three gradients (27.8%, 48.7%, 89.6%). The simulations of light interception were conducted under different ratios of diffuse light, before and after the normalization of incident radiation. With 226.1% more diffuse light, the result of light interception could increase by 34.4%. However, the 56.8% of reduced radiation caused by the increased proportion of diffuse light inhibited the advantage of diffuse light in terms of a 26.8% reduction in light interception. The big-leaf canopy had more mutual shading effects, but its larger leaf area intercepted 56.2% more light than the small-leaf canopy under the same light conditions. The small-leaf canopy showed higher efficiency in light penetration and higher light interception per unit of leaf area. The study implied the 3D structural model, an effective tool for quantitative analysis of the interaction between light and plant canopy structure.
MULTIFILE
This study explores the capability of the COMPASS system (IBADosimetry, Germany) to detect leaf positioning errors of a highresolution MLC with 4mm leaf width using a lower resolution(7.62mm detector spacing) 2D matrix of ionisation chambers
DOCUMENT
The objective of this study was to introduce a new iterative method to reconstruct multi leaf collimator (MLC) positions based on low resolution ionization detector array measurements and to evaluate its error detection performance. The iterative reconstruction method consists of a fluence model, a detector model and an optimizer. Expected detector response was calculated using a radiotherapy treatment plan in combination with the fluence model and detector model. MLC leaf positions were reconstructed by minimizing differences between expected and measured detector response. The iterative reconstruction method was evaluated for an Elekta SLi with 10.0 mm MLC leafs in combination with the COMPASS system and the MatriXX Evolution (IBA Dosimetry) detector with a spacing of 7.62 mm. The detector was positioned in such a way that each leaf pair of the MLC was aligned with one row of ionization chambers. Known leaf displacements were introduced in various field geometries ranging from −10.0 mm to 10.0 mm. Error detection performance was tested for MLC leaf position dependency relative to the detector position, gantry angle dependency, monitor unit dependency, and for ten clinical intensity modulated radiotherapy (IMRT) treatment beams. For one clinical head and neck IMRT treatment beam, influence of the iterative reconstruction method on existing 3D dose reconstruction artifacts was evaluated. The described iterative reconstruction method was capable of individual MLC leaf position reconstruction with millimeter accuracy, independent of the relative detector position within the range of clinically applied MU's for IMRT. Dose reconstruction artifacts in a clinical IMRT treatment beam were considerably reduced as compared to the current dose verification procedure. The iterative reconstruction method allows high accuracy 3D dose verification by including actual MLC leaf positions reconstructed from low resolution 2D measurements.
LINK
The growing demand for food due to a global population increase has made the use of pesticides in agriculture unavoidable despite their various harmful side effects. Driven by stricter legislation, nations are now compelled to find alternatives. This situation led to accelerated research around the world, focusing on developing new chemistries to enhance the environmental safety of pesticides. In recent years, bioinspired strategies of pest control have emerged as alternatives to the development of new synthetic pesticides. In order to design innovative eco-friendly pest management techniques, a thorough understanding of naturally existing physical and chemical defences in plants is needed. Building upon this knowledge, material science provides innovative strategies for designing physical barriers, biomimetic adhesives, and targeted delivery systems that go beyond traditional chemical approaches. This tutorial review explores the intricate relationships between plants and insects, focusing on natural defence mechanisms such as plant cuticles, trichomes, and thigmonasty. We also review advances in synthetic pesticide use, including enhanced adhesion and controlled release formulations. In addition, we delve into advances in other integrated pest management domains, discussing the potential of bioinspired surfaces and biological control methods. This overview aims to foster comprehensive understanding and interdisciplinary approaches, highlighting the pivotal role of material science in improving sustainable pest control for the future.
LINK
Background and purpose: Automatic approaches are widely implemented to automate dose optimization in radiotherapy treatment planning. This study systematically investigates how to configure automatic planning in order to create the best possible plans. Materials and methods: Automatic plans were generated using protocol based automatic iterative optimization. Starting from a simple automation protocol which consisted of the constraints for targets and organs at risk (OAR), the performance of the automatic approach was evaluated in terms of target coverage, OAR sparing, conformity, beam complexity, and plan quality. More complex protocols were systematically explored to improve the quality of the automatic plans. The protocols could be improved by adding a dose goal on the outer 2 mm of the PTV, by setting goals on strategically chosen subparts of OARs, by adding goals for conformity, and by limiting the leaf motion. For prostate plans, development of an automated post-optimization procedure was required to achieve precise control over the dose distribution. Automatic and manually optimized plans were compared for 20 head and neck (H&N), 20 prostate, and 20 rectum cancer patients. Results: Based on simple automation protocols, the automatic optimizer was not always able to generate adequate treatment plans. For the improved final configurations for the three sites, the dose was lower in automatic plans compared to the manual plans in 12 out of 13 considered OARs. In blind tests, the automatic plans were preferred in 80% of cases. Conclusions: With adequate, advanced, protocols the automatic planning approach is able to create high-quality treatment plans.
DOCUMENT
The seismic assessment of the out-of-plane (OOP) behaviour of unreinforced masonry (URM) buildings is essential since the OOP is one of the primary collapse mechanisms in URM buildings. It is influenced by several parameters, including the poor connections between structural elements, a weakness highlighted by post-earthquake observations. The paper presents a mechanical model designed to predict the contributions of various resisting mechanisms to the strength capacity of timber-joist connections in masonry cavity walls. The research presented in this paper considers two different failure modes: joist-wall interface failure, and OOP rocking behaviour of the URM walls. Consequently, two mechanical models are introduced to examine these failure modes in timber-joist connections within masonry cavity walls. One model focuses on the joist-wall interface failure, adopting a Coulomb friction model for joist-sliding further extended to incorporate the arching effect. The other model investigates the OOP rocking failure mode of walls. The combined mechanical model has been validated against the outcomes of an earlier experimental campaign conducted by the authors. The considered model can accurately predict the peak capacity of the joist connection and successfully defines the contribution of each mechanism in terms of resistance at failure.
DOCUMENT
Post-earthquake structural damage shows that out-of-plane (OOP) wall collapse is one of the most common failure mechanisms in unreinforced masonry (URM) buildings. This issue is particularly critical in Groningen, a province located in the northern part of the Netherlands, where low-intensity induced earthquakes have become an uprising problem in recent years. The majority of buildings in this area are constructed using URM and were not designed to withstand earthquakes, as the area had never been affected by tectonic seismic activity before. OOP failure in URM structures often stems from poor connections between structural elements, resulting in insufficient restraint to the URM walls. Therefore, investigating the mechanical behaviour of these connections is of prime importance for mitigating damages and collapses in URM structures. This paper presents the results of an experimental campaign conducted on timber joist-masonry cavity wall connections. The specimens consisted of timber joists pocketed into masonry wallets. The campaign aimed at providing a better understanding and characterisation of the cyclic axial behaviour of these connections. Both as-built and strengthened conditions were considered, with different variations, including two tie distributions, two pre-compression levels, two different as-built connections, and one strengthening solution. The experimental findings underscored that incorporating retrofitting bars not only restores the system's initial capacity but also guarantees deformation compatibility between the wall and the joist. This effectively enhances the overall deformation capacity and ductility of the timber joist-cavity wall system.
DOCUMENT