Cities are confronted with more frequent heatwaves of increasing intensity discouraging people from using urban open spaces that are part of their daily lives. Climate proofing cities is an incremental process that should begin where it is needed using the most cost-efficient solutions to mitigate heat stress. However, for this to be achieved the factors that influence the thermal comfort of users, such as the layout of local spaces, their function and the way people use them needs to be identified first. There is currently little evidence available on the effectiveness of heat stress interventions in different types of urban space.The Cool Towns Heat Stress Measurement Protocol provides basic guidance to enable a full Thermal Comfort Assessment (TCA) to be conducted at street-level. Those involved in implementing climate adaptation strategies in urban areas, such as in redevelopments will find practical support to identify places where heat stress may be an issue and suggestions for effective mitigation measures. For others, such as project developers, and spatial designers such as landscape architects and urban planners it provides practical instructions on how to evaluate and provide evidence-based justification for the selection of different cooling interventions for example trees, water features, and shade sails, for climate proofing urban areas.
MULTIFILE
Objective: To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. Data sources: PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. Study selection: VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/ or responsiveness of cardiopulmonary exercise test protocols. Data extraction: Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Data synthesis: Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. Conclusion: No judgement could be made on which protocol is “best” for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.
DOCUMENT
Background To gain insight into the role of plantar intrinsic foot muscles in fall-related gait parameters in older adults, it is fundamental to assess foot muscles separately. Ultrasonography is considered a promising instrument to quantify the strength capacity of individual muscles by assessing their morphology. The main goal of this study was to investigate the intra-assessor reliability and measurement error for ultrasound measures for the morphology of selected foot muscles and the plantar fascia in older adults using a tablet-based device. The secondary aim was to compare the measurement error between older and younger adults and between two different ultrasound machines. Methods Ultrasound images of selected foot muscles and the plantar fascia were collected in younger and older adults by a single operator, intensively trained in scanning the foot muscles, on two occasions, 1–8 days apart, using a tablet-based and a mainframe system. The intra-assessor reliability and standard error of measurement for the cross-sectional area and/or thickness were assessed by analysis of variance. The error variance was statistically compared across age groups and machines. Results Eighteen physically active older adults (mean age 73.8 (SD: 4.9) years) and ten younger adults (mean age 21.9 (SD: 1.8) years) participated in the study. In older adults, the standard error of measurement ranged from 2.8 to 11.9%. The ICC ranged from 0.57 to 0.97, but was excellent in most cases. The error variance for six morphology measures was statistically smaller in younger adults, but was small in older adults as well. When different error variances were observed across machines, overall, the tablet-based device showed superior repeatability. Conclusions This intra-assessor reliability study showed that a tablet-based ultrasound machine can be reliably used to assess the morphology of selected foot muscles in older adults, with the exception of plantar fascia thickness. Although the measurement errors were sometimes smaller in younger adults, they seem adequate in older adults to detect group mean hypertrophy as a response to training. A tablet-based ultrasound device seems to be a reliable alternative to a mainframe system. This advocates its use when foot muscle morphology in older adults is of interest.
MULTIFILE
The aim of this explorative study was to determine the key inertial measurement unit-based wheelchair mobility performance components during a wheelchair tennis match. A total of 64 wheelchair tennis matches were played by 15 wheelchair tennis players (6 women, 5 men, 4 juniors). All individual tennis wheelchairs were instrumented with inertial measurement units, two on the axes of the wheels and one on the frame. A total of 48 potentially relevant wheelchair tennis outcome variables were initially extracted from the sensor signals, based on previous wheelchair sports research and the input of wheelchair tennis experts (coaches, embedded scientists). A principal component analysis was used to reduce this set of variables to the most relevant outcomes for wheelchair tennis mobility. Results showed that wheelchair mobility performance in wheelchair tennis can be described by six components: rotations to racket side in (1) curves and (2) turns; (3) linear accelerations; (4) rotations to non-racket side in (4) turns and (5) curves; and finally, (6) linear velocities. One or two outcome variables per component were selected to allow an easier interpretation of results. These key outcome variables can be used to adequately describe the wheelchair mobility performance aspect of wheelchair tennis during a wheelchair tennis match and can be monitored during training.
DOCUMENT
Background: Lymphedema measurement is vital to select appropriate treatment and monitor its progress. Quantifying lymphedema in the head and neck area is challenging. The use of tissue dielectric constant (TDC) measurements has shown promising results in other body areas. This study aims to determine the test-retest reliability of a TDC measurement protocol developed for the head and neck area. Methods and Results: A detailed measurement protocol, including eight measurement points per side, was developed. Subsequently, the reliability of the protocol was tested in a sample of healthy participants (n = 50, 28 males). Using the LymphScanner (Delfin, Finland), participants were subjected to two measurement sessions. Each measurement point was measured three times per session. Test-retest reliability for each point was evaluated using intraclass correlation coefficients (ICCs) and standard errors of measurement (SEMs). Using the average of three measurements, reliability was good to excellent for all points (ICCs 0.81–0.95), with small measurement errors (SEMs 1.51–2.86). The reliability of a single measurement was moderate to excellent for all measurement points (ICCs 0.58–0.87), with larger, but still small, measurement errors (SEMs 1.65–3.39). When using single measurements, the lowest ICCs were found for the temporal (left 0.73 and right 0.67) and submandibular (left 0.58 and right 0.77) locations. Conclusion: Measurements with the LymphScanner, taken according to the developed protocol, are reliable in healthy participants. We recommend using the average of three measurements to optimize reliability. The protocol is fit for further testing in patient populations and for determining normal values in a larger scale study with healthy subjects.
DOCUMENT
Background. Barefoot plantar pressure measurements are routinely used in the risk evaluation for ulceration in diabetic patients with neuropathy. The aim was to compare three step-protocols commonly used for pressure assessment in these patients. Methods. Dynamic barefoot plantar pressures were measured in 14 diabetic neuropathic patients (vibration perception threshold >35 V) contacting a pressure platform on the first, second or third step after gait initiation. Ten repeated trials per step-protocol were collected. The 3-step protocol was regarded the reference protocol. Peak pressure, pressure-time integral and contact time were calculated for each of six anatomical foot regions. Intraclass correlation coefficients (ICC) were calculated to assess reliability in each protocol. Findings. Regional peak pressures and pressure-time integrals were not significantly different between protocols. Contact time was significantly different in the heel region between the 1-step and 3-step protocol only (P < 0.05). Intraclass correlation coefficients for the maximum 10 repeated trials were high (>0.87) and similar between protocols. Reliable estimates (ICC > 0.85) of peak pressure were achieved with three repeated trials in the 2-step protocol, and four in the other two; for pressure-time integral these numbers were 7 (1-step), 4 (2-step), and 5 trials (3-step). Interpretation. Barefoot plantar pressures in the diabetic neuropathic foot can be assessed in a reproducible manner with any of the step-protocols used. For this purpose, the 1-step and 2-step protocols prove to be valid methods. A 2-step protocol requires the least amount of repeated trials for obtaining reliable pressure data and may be recommended for assessment of these patients.
DOCUMENT
A list of measurement instruments used in Urban Vitality research projects regarding frailty and ageing. The list is based on the research protocols of the 14 projects that were examined.Per instrument a link to https://meetinstrumentenzorg.nl/instrumenten/ is provided (if available).
MULTIFILE
Validity and Reproducibility of a New Treadmill Protocol: The Fitkids Treadmill Test. Med. Sci. Sports Exerc., Vol. 47, No. 10, pp. 2241–2247, 2015. Purpose: This study aimed to investigate the validity and reproducibility of a new treadmill protocol in healthy children and adolescents: the Fitkids Treadmill Test (FTT). Methods: Sixty-eight healthy children and adolescents (6–18 yr) were randomly divided into a validity group (14 boys and 20 girls; mean T SD age, 12.9 T 3.6 yr) that performed the FTT and Bruce protocol, both with respiratory gas analysis within 2 wk, and a reproducibility group (19 boys and 15 girls; mean T SD age, 13.5 T 3.5 yr) that performed the FTT twice within 2 wk. A subgroup of 21 participants within the reproducibility group performed both FTT with respiratory gas analysis. Time to exhaustion (TTE) was the main outcome of the FTT. Results: V˙ O2peak measured during the FTT showed excellent correlation with V˙ O2peak measured during the Bruce protocol (r = 0.90; P G 0.01). Backward multiple regression analysis provided the following prediction equations for V˙ O2peak (LIminj1) for boys and girls, respectively: V˙ O2peak FTT ¼ j0:748 þ ð0:117 TTEFTTÞ þ ð0:032 bodymassÞ þ 0:263, and V˙ O2peak FTT ¼ j0:748 þ ð0:117 TTEFTTÞ þ ð0:032 bodymassÞ [R2 ¼ 0:935; SEE ¼ 0:256LI min j1]. Cross-validation of the regression model showed an R2 value of 0.76. Reliability statistics for the FTT showed an intraclass correlation coefficient of 0.985 (95% confidence interval, 0.971–0.993; P G 0.001) for TTE. Bland–Altman analysis showed a mean bias of j0.07 min, with limits of agreement between +1.30 and j1.43 min. Conclusions: Results suggest that the FTT is a useful treadmill protocol with good validity and reproducibility in healthy children and adolescents. Exercise performance on the FTT and body mass can be used to adequately predict V˙ O2peak when respiratory gas analysis is not available.
DOCUMENT
In BMC Oral Health verscheen het volgende artikel van Inholland-docente en promovenda Janneke Scheerman (en collega’s). Background: Adolescents with fixed orthodontic appliances are at high risk of developing dental caries. To date, new smartphone technologies have seldom been used to support them in the preventive behavior that can help prevent dental caries. After an intervention-mapping process, we developed a smartphone application (the WhiteTeeth app) for preventing dental caries through improved oral-health behavior and oral hygiene. The app, which is intended to be used at home, will help adolescents with fixed orthodontic appliances perform their oral self-care behavior. The app is based on the Health Action Process Approach (HAPA) theory, and incorporates several behavior-change techniques that target the psychosocial factors of oral-health behavior. This article describes the protocol of a randomized controlled trial (RCT) to evaluate the effects of the WhiteTeeth app on oral-health behavior and oral-hygiene outcomes (presence of dental plaque and gingival bleeding) compared with those of care as usual, in patients aged 12–16 with fixed orthodontic appliances.
DOCUMENT
Digitization of activities in hospitals receives more attention, due to Covid-19 related regulations. The use of e-health to support patient care is increasing and efficient ways to implement digitization of processes and other technological equipment are needed. We constructed a protocol for implementation and in this study, we evaluate this protocol based on a case to implement a device in the OR. We used various data sources to evaluate this protocol: semi-structured interviews, questionnaires, and project documents. Based on these findings, this protocol, including identified implementation activities and implementation instructions can be used for implementations of other devices. Implementation activities include setting up a project plan, organizational and technological preparation, maintenance, and training. In future research, these activities and instructions need to be evaluated in more complex projects and a flexible tool needs to be developed to select relevant activities and instructions for implementations of information systems or devices.
LINK