Inertial measurement units (IMUs) allow for measurements of kinematic movements outside the laboratory, persevering the athlete-environment relationship. To use IMUs in a sport-specific setting, it is necessary to validate sport-specific movements. The aim of this study was to assess the concurrent validity of the Xsens IMU system by comparing it to the Vicon optoelectronic motion system for lower-limb joint angle measurements during jump-landing and change-of-direction tasks. Ten recreational athletes performed four tasks; single-leg hop and landing, running double-leg vertical jump landing, single-leg deceleration and push off, and sidestep cut, while kinematics were recorded by 17 IMUs (Xsens Technologies B.V.) and eight motion capture cameras (Vicon Motion Systems, Ltd). Validity of lower-body joint kinematics was assessed using measures of agreement (cross-correlation: XCORR) and error (root mean square deviation and amplitude difference). Excellent agreement was found in the sagittal plane for all joints and tasks (XCORR > 0.92). Highly variable agreement was found for knee and ankle in transverse and frontal plane. Relatively high error rates were found in all joints. In conclusion, this study shows that the Xsens IMU system provides highly comparable waveforms of sagittal lower-body joint kinematics in sport-specific movements. Caution is advised interpreting frontal and transverse plane kinematics as between-system agreement highly varied.
AbstractIn many biomechanical motion studies, kinematic parameters are estimated from position measurements on a number of landmarks. In the present investigation, dummy motion experiments are performed in order to study the error dependence of kinematic parameters on geometric factors (number of markers, isotropic vs anisotropic landmark distributions, landmark distribution size), on kinematic factors (rotation step magnitude, the presence of translational displacements, the distance of the landmarks' mean position to the rotation axis), and on anisotropically distributed measurement errors. The experimental results are compared with theoretical predictions of a previous error analysis assuming isotropic conditions for the measurement errors and for the spatial landmark distribution. In general, the experimental findings agree with the predictions of the error model. The kinematic parameters such as translations and rotations are well-determined by the model. In the helical motion description, the same applies for the finite rotation angle about and the finite shift along the helical axis. However, the direction and position of the helical axis are ill-determined. An anisotropic landmark distribution with relatively few markers located in the direction of the rotation axis will even aggravate the ill-posed nature of the finite helical axis estimation.
Modifiable (biomechanical and neuromuscular) anterior cruciate ligament (ACL) injury risk factors have been identified in laboratory settings. These risk factors were subsequently used in ACL injury prevention measures. Due to the lack of ecological validity, the use of on-field data in the ACL injury risk screening is increasingly advocated. Though, the kinematic differences between laboratory and on-field settings have never been investigated. The aim of the present study was to investigate the lower-limb kinematics of female footballers during agility movements performed both in laboratory and football field environments. Twenty-eight healthy young female talented football (soccer) players (14.9 ± 0.9 years) participated. Lower-limb joint kinematics was collected through wearable inertial sensors (Xsens Link) in three conditions: (1) laboratory setting during unanticipated sidestep cutting at 40-50°; on the football pitch (2) football-specific exercises (F-EX) and (3) football games (F-GAME). A hierarchical two-level random effect model in Statistical Parametric Mapping was used to compare joint kinematics among the conditions. Waveform consistency was investigated through Pearson's correlation coefficient and standardized z-score vector. In-lab kinematics differed from the on-field ones, while the latter were similar in overall shape and peaks. Lower sagittal plane range of motion, greater ankle eversion, and pelvic rotation were found for on-field kinematics (p < 0.044). The largest differences were found during landing and weight acceptance. The biomechanical differences between lab and field settings suggest the application of context-related adaptations in female footballers and have implications in ACL injury prevention strategies. Highlights: Talented youth female football players showed kinematical differences between the lab condition and the on-field ones, thus adopting a context-related motor strategy. Lower sagittal plane range of motion, greater ankle eversion, and pelvic rotation were found on the field. Such differences pertain to the ACL injury mechanism and prevention strategies. Preventative training should support the adoption of non-linear motor learning to stimulate greater self-organization and adaptability. It is recommended to test football players in an ecological environment to improve subsequent primary ACL injury prevention programmes.