Abstract Background: The benefit of MR-only workflow compared to current CT-based workflow for prostate radiotherapy is reduction of systematic errors in the radiotherapy chain by 2–3 mm. Nowadays, MRI is used for target delineation while CT is needed for position verification. In MR-only workflows, MRI based synthetic CT (sCT) replaces CT. Intraprostatic fiducial markers (FMs) are used as a surrogate for the position of the prostate improving targeting. However, FMs are not visible on sCT. Therefore, a semi-automatic method for burning-in FMs on sCT was developed. Accuracy of MR-only workflow using semi-automatically burned-in FMs was assessed and compared to CT/MR workflow. Methods: Thirty-one prostate cancer patients receiving radiotherapy, underwent an additional MR sequence (mDIXON) to create an sCT for MR-only workflow simulation. Three sources of accuracy in the CT/MR- and MR-only workflow were investigated. To compare image registrations for target delineation, the inter-observer error (IOE) of FM-based CT-to-MR image registrations and soft-tissue-based MR-to-MR image registrations were determined on twenty patients. Secondly, the inter-observer variation of the resulting FM positions was determined on twenty patients. Thirdly, on 26 patients CBCTs were retrospectively registered on sCT with burned-in FMs and compared to CT-CBCT registrations. Results: Image registration for target delineation shows a three times smaller IOE for MR-only workflow compared to CT/MR workflow. All observers agreed in correctly identifying all FMs for 18 out of 20 patients (90%). The IOE in CC direction of the center of mass (COM) position of the markers was within the CT slice thickness (2.5 mm), the IOE in AP and RL direction were below 1.0 mm and 1.5 mm, respectively. Registrations for IGRT position verification in MR-only workflow compared to CT/MR workflow were equivalent in RL-, CC- and AP-direction, except for a significant difference for random error in rotation. Conclusions: MR-only workflow using sCT with burned-in FMs is an improvement compared to the current CT/ MR workflow, with a three times smaller inter observer error in CT-MR registration and comparable CBCT registration results between CT and sCT reference scans. Trial registry Medical Research Involving Human Subjects Act (WMO) does apply to this study and was approved by the Medical Ethics review Committee of the Academic Medical Center. Registration number: NL65414.018.18. Date of registration: 21–08-2018.
LINK
This study answers the questions on which factors drive the adoption of AI and MR in the multiplex retail environment and which factors drive consumers’ behavioral responses to the multiplex retail environment.
DOCUMENT
Rede, op samenvattende wijze gepresenteerd 21 maart 2023 door Mr Dr. Daisy G. Tempelman ter gelegenheid van haar installatie als Lector Juridische Vraagstukken binnen de energietransitie bij het Instituut voor Rechtenstudies en het Centre of Expertise – Energy aan de Hanzehogeschool Groningen. Lectoraat Juridische en economische vraagstukken binnen de energietransitie.
DOCUMENT
A presentation on our internal use of MR for marine spatial planning, and the qualitative research that went along with this project.
DOCUMENT
The aim of this research is to explore the potential of Mixed Reality (MR) technologies for Operator Support in order to progress towards Industry 4.0 (I4.0) particularly for SMEs. Through a series of interventions and interviews conducted with local SMEs, potential use cases and their drawbacks have been identified. From this, insights were derived that serve as a starting point for conducting further experiments with MR technology in the smart manufacturing laboratory at the THUAS in Delft. The intervention consisted of a free form workshop in which the participants get ‘tinkering’ time to explore MR in their own work environment. The various levels of awareness were assessed in three stages: during an introductory interview, and after an instruction meeting and some ‘tinkering’. The study took place in the period from January 2022 to July 2022 with 10 local SMEs in the Netherlands. The results show that for all SMEs the awareness and understanding increased. The use cases identified by operators themselves concerned Quality Control, Diagnostics, Instruction, Specification and Improvement of Operations. Drawbacks foreseen related to Ergonomic Concerns, Resistance from operators, Technical considerations, Unavailability of MR device and an insufficient digital infrastructure to support MR in full extent. The use case most promising to the participants was further developed into a physical prototype for an ‘assisted assembly cell’ by which the aspects of ergonomics and the mentioned technical considerations could be analysed.
MULTIFILE
Op 20 januari 2022 sprak mr. dr. Bart Wernaart zijn lectorale rede “Building value-based technology together" uit. Aansluitend werd Bart geïnstalleerd als lector Moral Design Strategy binnen Fontys Hogeschool Economie en Communicatie. Op deze website een verslag van alle onderdelen van die dag.
LINK
This report describes the results and recommendations of the assessment of a potential business model for the orchard of Mr. W. Hekkert, Terwolde, focusing on drying fruits for organic muesli.
DOCUMENT
PURPOSE: Limited information is available on the effect of Immediate Dentin Sealing (IDS) on the fracture strength of indirect partial posterior restorations. This study evaluated the effect of IDS on the fracture strength and failure types of two indirect restorative materials.MATERIALS AND METHODS: Standard MOD inlay preparations were made on sound molars (N=40, n=10 per group) and randomly divided into four groups to receive the inlay materials with and without the application of IDS: Group L-IDS-: Li2Si2O5 (Lithium disilicate, IPS e.max) without IDS; Group L-IDS+: Li2Si2O5 with IDS; Group MR-IDS-: Multiphase resin composite (MR, Lava Ultimate) without IDS; MR-IDS+: MR with IDS. Inlays made of L were etched with 5% hydrofluoric acid, and MR inlays were silica coated. After silanization, they were cemented using adhesive resin cement (Variolink Esthetic DC). The specimens were thermo-mechanically aged (1.2×106 cycles, 1.7Hz, 8000 cycles, 5-55°C) and then subjected to load to failure (1 mm/min). Failure types and locations of debondings were classified. Data were statistically analyzed using ANOVA, Mann Whitney U-test and Chi-square tests (α=0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale (m) and shape (0), values were calculated.RESULTS: After aging conditions, no apparent changes were observed in marginal integrity but occlusal wear facets were more common with MR than with L (p<0.001). Material type and the application of IDS significantly affected the results (p=0.013). While group L-IDS- showed the lowest mean fracture strength (1358±506N) among all groups (p<0.05), application of IDS significantly increased the results significantly (L-IDS+: 2035±403N) (p=0.006). MR groups with and without IDS, did not show significant difference (MR-IDS-: 1861±423, MR-IDS+: 1702±596 N) (p=0.498). When materials without IDS are compared, L showed significantly lower results than that of MR (p=0.035). With the application of IDS, no significant difference was noted between L and MR materials (p=0.160). Weibull distribution presented the highest shape (0) for L-IDS+ (5.66) compared to those of other groups (3.01-4.76). Neither the material type (p=0.830), nor the application of IDS (p=0.54) affected the severity of the failure types. In 95% of the cases, the IDS layer left adhered on the tooth surface after fracture tests. In groups where no IDS was used, resin cement remained on the tooth surface in 44% of the cases (p=0.001). No significant differences were observed between the materials with respect to cement remnants or IDS after fracture (p=0.880). The incidence of repairable failure types (83%) was more common with L than with MR (75%) material (p>0.05).CONCLUSION: Immediate dentin sealing improves adhesion, and thereby the fracture strength of inlays made of lithium disilicate but not that multiphase resin composite.
DOCUMENT
The use of immersive technologies has changed the consumption environment in which retailers provide services. We present findings from a study designed to investigate consumer responses toward a $17 million AI-embedded mixed reality (MR) exhibit in a retail/entertainment complex which combines advanced technology entertainment with retail shopping. Findings from our study demonstrate that the quality of AI (i.e., speech recognition and synthesis via machine learning) associated with an augmented object increases MR immersion associated with spatial immersion, MR enjoyment, and consumers’ perceptions of novel experiences. Collectively, these increase consumer engagement, and positively influence behavioral responses—specifically, purchase intentions and intentions to share experiences with social groups. Overall, findings from this study show that interactive AI and MR technology open new avenues to promote consumer engagement.
LINK
This booklet outlines a 'court case' about shaming someone's food choices. Dit boekwerk behandelt een 'rechtszaak' over het te schande maken van iemands voedselkeuzes.
DOCUMENT