INTRODUCTION: The conceptual ambiguity of the integrated care concept precludes a full understanding of what constitutes a well-integrated health system, posing a significant challenge in measuring the level of integrated care. Most available measures have been developed from a disease-specific perspective and only measure certain aspects of integrated care. Based on the Rainbow Model of Integrated Care, which provides a detailed description of the complex concept of integrated care, a measurement tool has been developed to assess integrated care within a care system as a whole gathered from healthcare providers' and managerial perspectives. This paper describes the methodology of a study seeking to validate the Rainbow Model of Integrated Care measurement tool within and across the Singapore Regional Health System. The Singapore Regional Health System is a recent national strategy developed to provide a better-integrated health system to deliver seamless and person-focused care to patients through a network of providers within a specified geographical region.METHODS: The validation process includes the assessment of the content of the measure and its psychometric properties.CONCLUSION: If the measure is deemed to be valid, the study will provide the first opportunity to measure integrated care within Singapore Regional Health System with the results allowing insights in making recommendations for improving the Regional Health System and supporting international comparison.
DOCUMENT
AIM To examine which instruments used to assess participation of children with acquired brain injury (ABI) or cerebral palsy (CP) align with attendance and/or involvement constructs of participation; and to systematically review measurement properties of these instruments in children with ABI or CP, to guide instrument selection. METHOD Five databases were searched. Instruments that quantified ‘attendance’ and/or ‘involvement’ aspects of participation according to the family of participation-related constructs were selected. Data on measurement properties were extracted and methodological quality of the studies assessed. RESULTS Thirty-seven instruments were used to assess participation in children with ABI or CP. Of those, 12 measured attendance and/or involvement. The reliability, validity, and responsiveness of eight of these instruments were examined in 14 studies with children with ABI or CP. Sufficient measurement properties were reported for most of the measures, but no instrument had been assessed on all relevant properties. Moreover, most psychometric studies have marked methodological limitations. INTERPRETATION Instruments to assess participation of children with ABI or CP should be selected carefully, as many available measures do not align with attendance and/or involvement. Evidence for measurement properties is limited, mainly caused by low methodological study quality. Future studies should follow recommended methodological guidelines.
DOCUMENT
A review has been completed for a verification and validation (V&V) of the (Excel) BioGas simulator or EBS model. The EBS model calculates the environmental impact of biogas production pathways using Material and Energy Flow Analysis, time dependent dynamics, geographic information, and Life Cycle analysis. Within this article a V&V method is researched, selected and applied to validate the EBS model. Through the use of the method described within this article: mistakes in the model are resolved, the strengths and weaknesses of the model are found, and the concept of the model is tested and strengthened. The validation process does not only improve the model but also helps the modelers in widening their focus and scope. This article can, therefore, also be used in the validation process of similar models. The main result from the V&V process indicates that the EBS model is valid; however, it should be considered as an expert model and should only be used by expert users.
DOCUMENT
This technical report describes "validation of the 'Target system definition"
DOCUMENT
This report describes the validation of a "framework that delivers insight into the tangible and intangible effects of a mobile (IT) system, before it is being implemented".
DOCUMENT
Due to a lack of transparency in both algorithm and validation methodology, it is diffcult for researchers and clinicians to select the appropriate tracker for their application. The aim of this work is to transparently present an adjustable physical activity classification algorithm that discriminates between dynamic, standing, and sedentary behavior. By means of easily adjustable parameters, the algorithm performance can be optimized for applications using different target populations and locations for tracker wear. Concerning an elderly target population with a tracker worn on the upper leg, the algorithm is optimized and validated under simulated free-living conditions. The fixed activity protocol (FAP) is performed by 20 participants; the simulated free-living protocol (SFP) involves another 20. Data segmentation window size and amount of physical activity threshold are optimized. The sensor orientation threshold does not vary. The validation of the algorithm is performed on 10 participants who perform the FAP and on 10 participants who perform the SFP. Percentage error (PE) and absolute percentage error (APE) are used to assess the algorithm performance. Standing and sedentary behavior are classified within acceptable limits (+/- 10% error) both under fixed and simulated free-living conditions. Dynamic behavior is within acceptable limits under fixed conditions but has some limitations under simulated free-living conditions. We propose that this approach should be adopted by developers of activity trackers to facilitate the activity tracker selection process for researchers and clinicians. Furthermore, we are convinced that the adjustable algorithm potentially could contribute to the fast realization of new applications.
DOCUMENT
Inertial measurement units (IMUs) allow for measurements of kinematic movements outside the laboratory, persevering the athlete-environment relationship. To use IMUs in a sport-specific setting, it is necessary to validate sport-specific movements. The aim of this study was to assess the concurrent validity of the Xsens IMU system by comparing it to the Vicon optoelectronic motion system for lower-limb joint angle measurements during jump-landing and change-of-direction tasks. Ten recreational athletes performed four tasks; single-leg hop and landing, running double-leg vertical jump landing, single-leg deceleration and push off, and sidestep cut, while kinematics were recorded by 17 IMUs (Xsens Technologies B.V.) and eight motion capture cameras (Vicon Motion Systems, Ltd). Validity of lower-body joint kinematics was assessed using measures of agreement (cross-correlation: XCORR) and error (root mean square deviation and amplitude difference). Excellent agreement was found in the sagittal plane for all joints and tasks (XCORR > 0.92). Highly variable agreement was found for knee and ankle in transverse and frontal plane. Relatively high error rates were found in all joints. In conclusion, this study shows that the Xsens IMU system provides highly comparable waveforms of sagittal lower-body joint kinematics in sport-specific movements. Caution is advised interpreting frontal and transverse plane kinematics as between-system agreement highly varied.
DOCUMENT
Abstract: Clinicians find it challenging to engage with patients who engage in self-harm. Improving the self-efficacy of professionals who treat self-harm patients may be an important step toward accomplishing better treatment of self-harm. However, there is no instrument available that assesses the self-efficacy of clinicians dealing with self-harm. The aim of this study is to describe the development and validation of the Self-Efficacy in Dealing with Self-Harm Questionnaire (SEDSHQ). This study tests the questionnaire’s feasibility, test-retest reliability, internal consistency, content validity, construct validity (factor analysis and convergent validity) and sensitivity to change. The Self-Efficacy in Dealing with Self-Harm Questionnaire is a 27-item instrument which has a 3-factor structure, as found in confirmatory factor analysis. Testing revealed high content validity, significant correlation with a subscale of the Attitude Towards Deliberate Self-Harm Questionnaire (ADSHQ), satisfactory test-retest correlation and a Cronbach’s alpha of 0.95. Additionally, the questionnaire was able to measure significant changes after an intervention took place, indicating sensitivity to change. We conclude that the present study indicates that the Self-Efficacy in Dealing with Self-Harm Questionnaire is a valid and reliable instrument for assessing the level of self-efficacy in response to self-harm.
DOCUMENT
This study aimed to design and validate the Teacher Identity Measurement Scale (TIMS) for assessing primary student teachers’ professional identity. Based on identity theory and a systematic review into quantitative instruments of teacher identity, teacher identity was decomposed in four first-order constructs: motivation, self image, self-efficacy, and task perception. This resulted in a measurement scale consisting of 46 items. The factorial design was examined by administering the TIMS to first- and second-year primary student teachers. In phase 1, involving 17 students, qualitative scale development methods were used to assess the construct validity. In phase 2, its second-order factor structure was tested and confirmed among a sample of 211 students. In phase 3, this structure was cross-validated among a new sample of 419 students. The instrument may contribute to understanding primary student teacher’s professional development and can be used as a tool to support the process of developing a professional teacher identity.
DOCUMENT
The aim of this study was to develop a valid instrument to measure student nurses’ perceptions of community care (SCOPE). DeVellis’ staged model for instrument development and validation was used. Scale construction of SCOPE was based on existing literature. Evaluation of its psychometric properties included exploratory factor analysis and reliability analysis. After pilot-testing, 1062 bachelor nursing students from six institutions in the Netherlands (response rate 81%) took part in the study. SCOPE is a 35-item scale containing: background variables, 11 measuring the affective component, 5 measuring community care perception as a placement, 17 as a future profession, and 2 on the reasons underlying student preference. Principal axis factoring yielded two factors in the affective component scale reflecting ‘enjoyment’ and ‘utility’, two in the placement scale reflecting ‘learning possibilities’ and ‘personal satisfaction’, and four in the profession scale: ‘professional development’, ‘collaboration’, ‘caregiving’, and ‘complexity and workload’. Cronbach’s α of the complete scale was .892 and of the subscales .862, .696, and .810 respectively. SCOPE is a psychometrically sound instrument for measuring students’ perceptions of community care. By determining these perceptions, it becomes possible to positively influence them with targeted curriculum redesign, eventually contributing to decreasing the workforce shortage in community nursing.
DOCUMENT