BACKGROUND: Hemodynamic assessment of critically ill patients is a challenging endeavor, and advanced monitoring techniques are often required to guide treatment choices. Given the technical complexity and occasional unavailability of these techniques, estimation of cardiac function based on clinical examination is valuable for critical care physicians to diagnose circulatory shock. Yet, the lack of knowledge on how to best conduct and teach the clinical examination to estimate cardiac function has reduced its accuracy to almost that of "flipping a coin."OBJECTIVE: The aim of this study was to investigate the decision-making process underlying estimates of cardiac function of patients acutely admitted to the intensive care unit (ICU) based on current standardized clinical examination using Bayesian methods.METHODS: Patient data were collected as part of the Simple Intensive Care Studies-I (SICS-I) prospective cohort study. All adult patients consecutively admitted to the ICU with an expected stay longer than 24 hours were included, for whom clinical examination was conducted and cardiac function was estimated. Using these data, first, the probabilistic dependencies between the examiners' estimates and the set of clinically measured variables upon which these rely were analyzed using a Bayesian network. Second, the accuracy of cardiac function estimates was assessed by comparison to the cardiac index values measured by critical care ultrasonography.RESULTS: A total of 1075 patients were included, of which 783 patients had validated cardiac index measurements. A Bayesian network analysis identified two clinical variables upon which cardiac function estimate is conditionally dependent, namely, noradrenaline administration and presence of delayed capillary refill time or mottling. When the patient received noradrenaline, the probability of cardiac function being estimated as reasonable or good P(ER,G) was lower, irrespective of whether the patient was mechanically ventilated (P[ER,G|ventilation, noradrenaline]=0.63, P[ER,G|ventilation, no noradrenaline]=0.91, P[ER,G|no ventilation, noradrenaline]=0.67, P[ER,G|no ventilation, no noradrenaline]=0.93). The same trend was found for capillary refill time or mottling. Sensitivity of estimating a low cardiac index was 26% and 39% and specificity was 83% and 74% for students and physicians, respectively. Positive and negative likelihood ratios were 1.53 (95% CI 1.19-1.97) and 0.87 (95% CI 0.80-0.95), respectively, overall.CONCLUSIONS: The conditional dependencies between clinical variables and the cardiac function estimates resulted in a network consistent with known physiological relations. Conditional probability queries allow for multiple clinical scenarios to be recreated, which provide insight into the possible thought process underlying the examiners' cardiac function estimates. This information can help develop interactive digital training tools for students and physicians and contribute toward the goal of further improving the diagnostic accuracy of clinical examination in ICU patients.TRIAL REGISTRATION: ClinicalTrials.gov NCT02912624; https://clinicaltrials.gov/ct2/show/NCT02912624.
DOCUMENT
Current methods for energy diagnosis in heating, ventilation and air conditioning (HVAC) systems are not consistent with process and instrumentation diagrams (P&IDs) as used by engineers to design and operate these systems, leading to very limited application of energy performance diagnosis in practice. In a previous paper, a generic reference architecture – hereafter referred to as the 4S3F (four symptoms and three faults) framework – was developed. Because it is closely related to the way HVAC experts diagnose problems in HVAC installations, 4S3F largely overcomes the problem of limited application. The present article addresses the fault diagnosis process using automated fault identification (AFI) based on symptoms detected with a diagnostic Bayesian network (DBN). It demonstrates that possible faults can be extracted from P&IDs at different levels and that P&IDs form the basis for setting up effective DBNs. The process was applied to real sensor data for a whole year. In a case study for a thermal energy plant, control faults were successfully isolated using balance, energy performance and operational state symptoms. Correction of the isolated faults led to annual primary energy savings of 25%. An analysis showed that the values of set probabilities in the DBN model are not outcome-sensitive. Link to the formal publication via its DOI https://doi.org/10.1016/j.enbuild.2020.110289
DOCUMENT
In practice, faults in building installations are seldom noticed because automated systems to diagnose such faults are not common use, despite many proposed methods: they are cumbersome to apply and not matching the way of thinking of HVAC engineers. Additionally, fault diagnosis and energy performance diagnosis are seldom combined, while energy wastage is mostly a consequence of component, sensors or control faults. In this paper new advances on the 4S3F diagnose framework for automated diagnostic of energy waste in HVAC systems are presented. The architecture of HVAC systems can be derived from a process and instrumentation diagram (P&ID) usually set up by HVAC designers. The paper demonstrates how all possible faults and symptoms can be extracted on a very structured way from the P&ID, and classified in 4 types of symptoms (deviations from balance equations, operational states, energy performances or additional information) and 3 types of faults (component, control and model faults). Symptoms and faults are related to each other through Diagnostic Bayesian Networks (DBNs) which work as an expert system. During operation of the HVAC system the data from the BMS is converted to symptoms, which are fed to the DBN. The DBN analyses the symptoms and determines the probability of faults. Generic indicators are proposed for the 4 types of symptoms. Standard DBN models for common components, controls and models are developed and it is demonstrated how to combine them in order to represent the complete HVAC system. Both the symptom and the fault identification parts are tested on historical BMS data of an ATES system including heat pump, boiler, solar panels, and hydronic systems. The energy savings resulting from fault corrections are estimated and amount 25%. Finally, the 4S3F method is extended to hard and soft sensor faults. Sensors are the core of any FDD system and any control system. Automated diagnostic of sensor faults is therefore essential. By considering hard sensors as components and soft sensors as models, they can be integrated into the 4S3F method.
DOCUMENT