Renewable energy is often suggested as a possible solution for reducing greenhouse gas emissions and decreasing dependency on fossil energy sources. The most readily available renewable energy sources in Europe, wind, solar and biomass are dispersed by nature, making them ideally suited for use within Decentralized Energy Systems. Decentralized energy grids can help integrate renewable production, short lived by-products e.g. heat, minimize transport of energy carriers and fuel sources and reduce the dependency on fossils, hence, possibly improving the overall efficiency and sustainability of the energy distribution system. Within these grids balance between local renewable production and local energy demand is an important subject. Currently, fluctuations between demand and production of energy are mainly balanced by input from conventional power stations, which operate on storable fossil energy sources e.g. coal, oil, natural gas and nuclear. Within the long term scope of transition towards a low carbon intensive energy system, sustainable systems must be found which can replace fossil energy sources as load balancer in our energy supply systems.
DOCUMENT
Uit het rapport: "Deze onderzoeksagenda is tot stand gebracht door de lectoren die samenwerken in het Nationaal Lectoren Platform Urban Energy. Alle betrokkenen bij het platform zijn in staat gesteld om bij te dragen aan de tekst, speciale dank daarbij voor de bijdragen en commentaren vanuit de TKI Urban Energy en de HCA topsector Energie."
DOCUMENT
Droop control is used for power management in DC grids. Based on the level of the DC grid voltage, the amount of power regulated to or from the appliance is regulated such, that power management is possible. The Universal 4 Leg is a laboratory setup for studying the functionality of a grid manager for power management. It has four independent outputs that can be regulated with pulse width modulation to control the power flow between the DC grid and for example, a rechargeable battery, solar panel or any passive load like lighting or heating.
DOCUMENT
This paper presents the design of the offshore energy simulation CEL as a flow network, and its integration in the MSP Challenge 2050 simulation game platform. This platform is designed to aid learning about the key characteristics and complexity of marine or maritime spatial planning (MSP). The addition of CEL to this platform greatly AIDS MSP authorities in learning about and planning for offshore energy production, a highly topical and big development in human activities at sea. Rather than a standard flow network, CEL incorporates three additions to accommodate for the specificities of energy grids: an additional node for each team's expected energy, a split of each node representing an object into input and output parts to include the node's capacity, and bidirectional edges for all cables to enable more complex energy grid designs. Implemented with Dinic's algorithm it takes less than 30ms for the simulation to run for the average amount of grids included in an MSP Challenge 2050 game session. In this manner CEL enables MSP authorities and their energy stakeholders to use MSP Challenge 2050 for designing and testing more comprehensive offshore energy grids.
DOCUMENT
The need for increasing further the penetration of Renewable Energy Sources (RESs) is demanding a change in the way distribution grids are managed. In particular, the RESs intermittent and stochastic nature is finding in Battery Energy Storage (BES) systems its most immediate countermeasure. This work presents a reality-based assessment and comparison of the impact of three different BES technologies on distribution grids with high RES penetration, namely Li-ion, Zn-Air and Redox Flow. To this end, a benchmark distribution grid with real prosumers’ generation and load profiles is considered, with the RES penetration purposely scaled up in such a way as to violate the grid operational limits. Then, further to the BES(s) placement on the most affected grid location(s), the impact of the three BES types is assessed considering two Use Cases: 1) Voltage & Congestion Management and 2) Peak Shaving & Energy shifting. Assessment is conducted by evaluating a set of technical Key Performance Indicators (KPIs), together with a simplified economic analysis.
DOCUMENT
There is an ongoing transition towards renewable energy sources in order to combat climate change. National power grids are suffering due to the rapid introduction of new energy sources and have other disadvantages. Local Energy Systems (LESs) are a beneficial example of an off-grid energy systems that can aid the energy transition. LESs are community driven and require participating and steering members. This can be achieved through empowering end-users to become active participants or steerers. End-users can be empowered to become an active participant through engagement with energy management activities. This does not work for empowering to steer, which begs the question, how to empower end-users or participants to become steerers in Local Energy Systems. Through a literature review this study explores the importance of establishing a group containing steerers with diverse skills, strong leadership, and engagement with the environment and community. Additionally, this study identifies the strategy that empowers end-users to steer. Which is training technological and managemental skills; and training capabilities in establishing relations with local participants and intermediary organisations. To apply these findings more precisely a secondary analysis is conducted on a survey with 599 participants. The original study researched willingness to participate in LESs, however the secondary analysis establishes three important factors to predict willingness to steer. These are energy independence, community trust, and community resistance. Additionally, men with a high level of education are most willing to become steerers per default, thus different demographics generally require more empowerment.
DOCUMENT
Biogas can be seen as a flexible and storable energy carrier, capable of absorbing intermittent energy production and demand. However, the sustainability and efficiency of biogas production as a flexible energy provider is not fully understood. This research will focus on simulating biogas production within decentralised energy systems. Within these system several factors need to be taken into account, including, biomass availability, energy demand, energy production from other decentralised energy sources and factors influencing the biogas production process. The main goal of this PhD. research is to design and develop a method capable of integrating biomass availability, energy demand, biogas production, in a realistic dynamic geographical model, such that conclusions can be drawn on mainly the sustainability, and additionally on the efficiency, flexibility and economy of biogas production in the near and far future (2012 to 2050), within local decentralised smart energy grids. Furthermore. This research can help determining the best use of biogas in the near and far future.
DOCUMENT
Battery energy storage (BES) can provide many grid services, such as power flow management to reduce distribution grid overloading. It is desirable to minimise BES storage capacities to reduce investment costs. However, it is not always clear how battery sizing is affected by battery siting and power flow simultaneity (PFS). This paper describes a method to compare the battery capacity required to provide grid services for different battery siting configurations and variable PFSs. The method was implemented by modelling a standard test grid with artificial power flow patterns and different battery siting configurations. The storage capacity of each configuration was minimised to determine how these variables affect the minimum storage capacity required to maintain power flows below a given threshold. In this case, a battery located at the transformer required 10–20% more capacity than a battery located centrally on the grid, or several batteries distributed throughout the grid, depending on PFS. The differences in capacity requirements were largely attributed to the ability of a BES configuration to mitigate network losses. The method presented in this paper can be used to compare BES capacity requirements for different battery siting configurations, power flow patterns, grid services, and grid characteristics.
DOCUMENT