Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintainingimage quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children.Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality.However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength threeis optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature forpaediatric patients is noted.Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
DOCUMENT
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality.Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT.Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOMPERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale.Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3and higher.Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.
DOCUMENT
Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children.This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE).Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluatedvisual image quality. Dose was measured using CT-Expo.Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images.Conclusion: SAFIRE 5 was optimal for dose reduction and image quality
DOCUMENT
This thesis focuses on topics such as preterm birth, variation in gross motor development, factors that influence (premature) infant gross motor development, and parental beliefs and practices. By gaining insight into these topics, this thesis aims to contribute to clinical decision-making of paediatric physiotherapists together with parents, and with that shape early intervention.
DOCUMENT
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP).Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithmshas the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently.Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction.Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014).Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality.Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiationsensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
DOCUMENT
Samenvatting: In het kader van een afstudeerproject zijn data van 33 kinderen verzameld die een X-abdomen onderzoek ondergingen in het Wilhelmina Kinderziekenhuis. Uit deze data zijn curves afgeleid van Dosis Oppervlakte Product (DOP) ten opzichte van het lichaamsgewicht om te dienen als Diagnostisch ReferentieNiveau (DRN). De spreiding in de data leidt echter tot onzekerheid over de beste DRN-curve. Die curve is bovendien slechts gebaseerd op de data van één ziekenhuis en is daarmee hooguit bruikbaar als lokaal DRN. Door deze studie te herhalen in andere ziekenhuizen en meer data te verzamelen zou een nationale DRN-curve afgeleid kunnen worden. Zo’n curve zou de toetsing van doses aan DRN’s voor kinderen vergemakkelijken.
DOCUMENT
Background: Traumatic brain injury (TBI) is in the developed countries the most common cause of death and disability in childhood. Aim: The purpose of this study is to estimate the incidence of TBI for children and young people in an urbanised region of the Netherlands and to describe relevant characteristics of this group. Methods: Patients, aged 1 month - 24 years who presented with traumatic brain injury at the Erasmus University Hospital (including the Sophia Children's Hospital) in 2007 and 2008 were included in a retrospective study. Data were collected by means of diagnosis codes and search terms for TBI in patient records. The incidence of TBI in the different referral areas of the hospital for standard, specialised and intensive patient care was estimated. Results: 472 patients met the inclusion criteria. The severity of the Injury was classified as mild in 342 patients, moderate in 50 patients and severe in 80 patients. The total incidence of traumatic brain injury in the referral area of the Erasmus University Hospital was estimated at 113.9 young people per 100.000. The incidence for mild traumatic brain injury was estimated at 104.4 young people, for moderate 6.1 and for severe 3.4 young people per 100.000. Conclusion: The ratio for mild, moderate and severe traumatic brain injury in children and young people was 33.7e1.8e1.In the mild TBI group almost 17% of the patients reported sequelae. The finding that 42% of them had a normal brain CT scan at admission underwrites the necessity of careful follow up of children and young people with mild TBI.
DOCUMENT
Hospitalisation is stressful for children. Play material is often offered for distraction and comfort. Weexplored how contact with social robot PLEO could positively affect a child’s well-being. To this end, we performed a multiple case study on the paediatric ward of two hospitals. Child life specialists offered PLEO as a therapeutic activity to children in a personalised way for a well-being related purpose in three to five play like activity sessions during hospital visits/stay. Robot–child interaction was observed; care professionals, children and parents were interviewed. Applying direct content analysis revealed six categories of interest: interaction with PLEO, role of the adults, preferences for PLEO, PLEO as buddy, attainment of predetermined goal(s) and deployment of PLEO. Four girls and five boys, aged 4–13, had PLEO offered as a relief from stress or boredom or for physical stimulation. All but one started interacting with PLEO and showed behaviours like hugging, caring or technical exploration, promoting relaxation, activation and/or making contact. Interaction with PLEO contributed to achieving the well-being related purpose for six of them. PLEO was perceived as attractive to elicit play. Although data are limited, promising results emerge that the well-being of hospitalised children might be fostered by a personalised PLEO offer.
DOCUMENT
Objectives: Participation is considerably restricted in children and adolescents with acquired brain injury (ABI) as compared to their healthy peers. This systematic review aims to identify which factors are associated with participation in children and adolescents with ABI. Methods: A systematic search in Medline and various other electronic databases from January 2001–November 2014 was performed. All clinical studies describing determinants of participation at least 1 year after the diagnosis of ABI by means of one or more pre-defined instruments in patients up to 18 years of age were included. Extracted data included study characteristics, patient characteristics, participation outcome and determinants of participation (categorized into: health conditions (including characteristics of ABI), body functions and structures, activities, personal factors and environmental factors). The methodological quality of the studies was evaluated based on three quality aspects (selection, information and statistical analysis bias) and scored as low, moderate or high. Results: Eight studies using an explicit participation outcome measure were selected after review, including a total of 1863 patients, with a follow-up ranging from 1 up to 288 months. Three studies included patients with a traumatic or a non-traumatic brain injury (TBI or NTBI) and five studies with only TBI patients. Factors consistently found to be associated with more participation restrictions were: greater severity of ABI, impaired motor, cognitive, behavioural and/or sensory functioning, limited accessibility of the physical environmentand worse family functioning. Fewer participation problems were associated with a supportive/nurturing parenting style, higher household income, acceptance and support in the community and availability of special programmes. The overall methodological quality of the included studies was high in two and moderate in six studies. Conclusion: This systematic review shows that only a few, moderate quality, studies on the determinants of participation after paediatric ABI using recommended explicit measurement instruments are available. Various components of the ICF model: health condition, body functions and structures and environmental factors were consistently found to be associated with participation. More methodologically sound studies, using the recommended explicit outcome measures, a standardized set of potential determinants and longterm follow-up are suggested to increase the knowledge on participation in children and youth with ABI.
DOCUMENT
Introduction: The Netherlands does not have a national guideline for performing radiographic examinations on pregnant patients. Radiographic examination is a generic term for all examinations performed using ionizing radiation, including but not limited to radiographs, fluoroscopy and computed tomography. A pilot study amongst radiographers (Medical Radiation Technologists (MRTs)) showed that standardized practice of radiographic examinations on pregnant women is not evident between Radiology departments and that there is a need for a national guideline as the varying practice methods may lead to confusion and uncertainty amongst both patients and MRTs. Methods: Focus groups consisting of MRTs from several Radiology departments within the Netherlands were used to map ideas and requirements as to what should be included in the national guideline. Nine focus group sessions were organized with a total of 52 participants. Using a previous review (Wit, Fleur; Vroonland, Colinda; Bijwaard H. Pre-natal X-ray exposure and the risk of developing paediatric cancer; a systematic review of risk factors and a comparison of international guidelines. Health Physics 2021; 121 (3):225e233), the following key points were chosen as discussion topics for the focus group sessions: dose reduction, confirming pregnancy and risk communication. Results: Results showed that the participating MRTs did not agree on the use of lead aprons. That the national guideline should include standardized methods to adjust parameters to decrease radiation dose. Focus group participants find it difficult to ask a patient's pregnancy status, especially when dealing with relatively young and old (er) patients. When communicating the level of risk associated with a radiographic examination the participating MRTs would like to be able to use examples and comparisons, preferably by means of a multilingual website. Conclusion: A national guideline must include information on justification, available alternatives, dose reductions methods and confirmation of pregnancy requirements when fetal dose is a significant risk. Implications for practice: A national guideline ensures standardized practice can be implemented in Radiology departments, increasing clarity of the issues for both patients and MRTs.
DOCUMENT