During the 2015 Gorkha earthquake of 7.8 Mw that hit Kathmandu Valley, Nepal, numerous Nepalese Pagodas suffered extensive damage while others collapsed. Risk reduction strategies implemented in the region focused on disassembling historical structures and rebuilding them with modern material without in depth analysis of why they suffer damage and collapse. The aim of this paper is to evaluate the effectiveness of low-cost, low-intervention, reversible repair and strengthening options for the Nepalese Pagodas. As a case study, the Jaisedewal Temple, typical example of the Nepalese architectural style, was investigated. A nonlinear three-dimensional finite element model of the Jaisedewal Temple was developed and the seismic performance of the temple was assessed by undertaking linear, nonlinear static and nonlinear dynamic analyses. Also, different structural intervention options, suggested by local engineers and architects working in the restoration of temples in Nepal, were examined for their efficacy to withstand strong earthquake vibrations. Additionally, the seismic response of the exposed foundation that the Nepalese Pagodas are sitting on was investigated. From the results analysis, it was found that pushover analysis failed to capture the type of failure which highlights the necessity to perform time-history analysis to accurately evaluate the seismic response of the investigated temple. Also, stiffening the connections along the temple was found to enhance the seismic behaviour of the temple, while strengthening the plinth base was concluded to be insignificant. Outputs from this research could contribute towards the strategic planning and conservation of multi-tiered temples across Nepal and reduce their risk to future earthquake damage without seriously affecting their beautiful architectural heritage.
DOCUMENT
Kahramanmaraş Earthquake Sequence of 6th of February is the deadliest earthquake that happened in Turkey in the era of instrumental seismology, claiming more than 55 thousand lives and leaving torn down cities and towns behind. More than 450 km long lateral strike-slip fault ruptured during these catastrophic earthquakes. As a result, more than 38 thousand buildings collapsed causing life losses. Considering that the large share of the Turkish building stock consists of RC buildings, the vulnerable RC building stock is the main responsible for this picture. Deficiencies of the Turkish RC building stock are well known since they manifested themselves several times in the past earthquakes. However, considering the improvements in the seismic codes and the seismic hazard maps achieved in the last two decades, the widespread collapse of buildings constructed after year 2000 was rather unexpected. Some of the observed structural damage patterns are similar to those observed also in the pre-2000 buildings in recent earthquakes, however, some other types of damages, such as out-of-plane bending and shear failures or shear-friction capacity failure of RC walls, brittle fracture and bond-slip failure of reinforcement, tension failure of beams and slabs are usually not witnessed. This paper presents a carefully selected set of examples comparing the pre-2000 and post-2000 building damages and collapses, also referring to a detailed summary and comparison of the code developments in Turkey.
DOCUMENT
Mild steel is relatively low-cost and easily accessible material to fabricate some structural members. It would be a significant advantage if seismic energy dissipaters that are used in structures constructed in the earthquake prone areas, could also be produced on site. In this paper, a promising seismic energy dissipater made of mild steel, so-called steel cushion (SC) is presented. It is provided experimental and analytical responses of SCs subjected to bi-axial loadings. SC rolls under the lateral loading that allows relocation of the plasticized cross-section. Henceforth, SC dissipates considerable amount of seismic energy. A series of tests were performed to achieve experimentally the behavior of SC subjected to longitudinal and transversal loading. Finite Element Models (FEMs) were also generated to reproduce the experimental backbone curves and to predict the bi-directional response properties for discrete transversal forces and plate thicknesses. Closed-form equations were derived to determine yield and ultimate forces and the corresponding displacements as well as location of the plasticized sections. The behavior of SC could either be projected by the FEMs with the exhibited parameters or by means of the proposed closed-form equations and the normalized design chart.
LINK
The Ph.D. candidate will investigate the seismic response of connection details frequently used in traditional Dutch construction practice, specifically in the Groningen area. The research will focus on the experimental and numerical definition of the complete load-deflection behaviour of each considered connection; specifically, the tests will aim at identifying stiffness, strength, ductility, and dissipative behaviour of the connections. The experiments will be conducted on scaled or full-scale components that properly resemble the as-built and retrofitted as well connection details. The tests will involve monotonic and cyclic loading protocols to be able to define the load and displacement response of the connection to reversal loads, such as earthquakes, as well as the development of failure mechanisms under such loading cases. Possibly, also dynamic tests will be performed. Numerical models will be created and calibrated versus the experimental findings. Characteristic hysteretic behaviours of the examined connection types will be provided for the use of engineers and researchers.
The project is for protecting valuable museum contents against seismic actions. Assessment and protection methods and equipment will be developed and tested. - Assessment methods for seismic safety of museum contents- Protective devices for the musem contentsA museum virtual exhibition room (MVER) will be created, it will contain exhibits such as sculptures and artefacts of different size and geometry, while the proposed experimental work will first examine the seismic behaviour of the test specimens without any protection system. The tests will be repeated using different protective configurations, emphasising on low-mass base isolation systems. Two new and highly efficient base isolation systems will be extensively tested for the first time. The first isolator is a pendulum-based system, while the second utilises shape-memory-alloy wires.The project will also develop and calibrate novel numerical models for single- and two- block rocking systems, while experimental and numerical results will be combined in order to develop quick overturning assessment criteria for the artefacts considered.The final task of the project will combine the shaking table experimental outcomes with numerical results using calibrated numerical models in order to develop fragility curves for museum artefacts.
In recent years, human-induced seismicity in the northern part of the Netherlands increased rendering the seismic response of unreinforced masonry (URM) structures critical. Majority of the existing buildings in the Netherlands are URM, which are not designed to withstand earthquakes. This issue motivates engineering and construction companies in the region to research on the seismic assessment of the existing structures.The companies working in the structural engineering field in the region were forced to adapt very quickly to the earthquake related problems, such as strengthening of existing buildings after earthquake. Such solutions are of prime importance for the Groningen region due to the extent of the earthquake problems and need for strengthening the houses. The research published in the literature show that the connections play an important role in seismic resistant of the houses. Fixing or improving the poor wall-to-wall or floor-to-wall connections may have a large positive impact on the overall seismic behaviour. Some strengthening solutions are already provided by SMEs, and an extensive experimental campaign was carried out at TU Delft on retrofitted connections. In this project, a new experiment will be run on a large shake-table, unique in the Netherlands, that can simulate earthquake vibrations. These tests, together with the previous experience, will complement the overall knowledge on the strengthening solutions and their performance under real-time actual earthquake vibrations.