The six-minute walk test (6MWT) is a self-paced, submaximal exercise test used to assess functional exercise capacity in patients with chronic diseases (Chang 2006, Solway et al 2001). It has been used widely in adults, and is being utilised increasingly in paediatric populations; it has been used as an estimate of physical fitness in, for example, children with severe cardiopulmonary disease, cystic fibrosis, and juvenile idiopathic arthritis (Hassan et al 2010).
DOCUMENT
Background The Six-Minute Walk Test (6MWT) is increasingly being used as a functional outcome measure for chronic pediatric conditions. Knowledge about its measurement properties is needed to determine whether it is an appropriate test to use. Purpose The purpose of this study was to systematically review all published clinimetric studies on the 6MWT in chronic pediatric conditions. Data Sources The databases MEDLINE, EMBASE, CINAHL, PEDro, and SPORTDiscus were searched up to February 2012. Study Selection Studies designed to evaluate measurement properties of the 6MWT in a chronic pediatric condition were included in the systematic review. Data Extraction The methodological quality of the included studies and the measurement properties of the 6MWT were examined. Data Synthesis A best evidence synthesis was performed on 15 studies, including 9 different chronic pediatric conditions. Limited evidence to strong evidence was found for reliability in various chronic conditions. Strong evidence was found for positive criterion validity of the 6MWT with peak oxygen uptake in some populations, but negative criterion validity was found in other populations. Construct validity remained unclear in most patient groups because of methodological flaws. Little evidence was available for responsiveness and measurement error. Studies showed large variability in test procedures despite existing guidelines for the performance of the 6MWT. Limitations Unavailability of a specific checklist to evaluate the methodological quality of clinimetric studies on performance measures was a limitation of the study. Conclusions Evidence for measurement properties of the 6MWT varies largely among chronic pediatric conditions. Further research is needed in all patient groups to explore the ability of the 6MWT to measure significant and clinically important changes. Until then, changes measured with the 6MWT should be interpreted with caution. Future studies or consensus regarding modified test procedures in the pediatric population is recommended.
DOCUMENT
Introduction: The 6-minute walk test is a submaximal exercise test used to quantify the functional exercise capacity in clinical populations. It measures the distance walked within a period of 6-minutes. Obtaining reference values in the pediatric population is especially demanding due to factors as the development stage and age. RV provide a comparative basis for answering questions concerning the normality of health status, exercise responses and functional exercise capacity in patients. Areas covered: The aim of this review is to provide an overview of reference values and reference value prediction equations for the 6-minute walk test in the children and in adolescent pediatric population and of the methodology used to obtain them. A total of 22 studies from MEDLINE, EMBASE and Cinahl were included containing healthy participants aged ≤18 years. Reported reference values ranged from 383 m ± 41 m to 799 m ± 54 m. The prediction equation 6MWD = (4.63*height(cm))–(3.53*weight(kg))+(10.42*age)+56.32 yields the highest R2 value (0.6). Expert commentary: It is impossible to present a single best reference value. A flow-chart is presented to aid the selection of reference values or reference value prediction equations. Consensus regarding testing procedures should lead to an update and stricter application of the current guidelines.
DOCUMENT
Aim and method: To examine in obese people the potential effectiveness of a six-week, two times weekly aquajogging program on body composition, fitness, health-related quality of life and exercise beliefs. Fifteen otherwise healthy obese persons participated in a pilot study. Results: Total fat mass and waist circumference decreased 1.4 kg (p = .03) and 3.1 cm (p = .005) respectively. The distance in the Six-Minute Walk Test increased 41 meters (p = .001). Three scales of the Impact of Weight on Quality of Life-Lite questionnaire improved: physical function (p = .008), self-esteem (p = .004), and public distress (p = .04). Increased perceived exercise benefits (p = .02) and decreased embarrassment (p = .03) were observed. Conclusions: Aquajogging was associated with reduced body fat and waist circumference, and improved aerobic fitness and quality of life. These findings suggest the usefulness of conducting a randomized controlled trial with long-term outcome assessments.
DOCUMENT
Voor het meten van de mobiliteit bij geriatrische patiënten en bij patiënten met evenwichtsstoornissen is in 1986 door Mathias de Timed Up and Go test (TUG) ontwikkeld. Deze oorspronkelijk Engelstalige versie van de test werd in 2000 in het Nederlands vertaald door De Jong. Het meetinstrument is zowel evaluatief als inventariserend en wordt aanbevolen in de KNGF-richtlijnen ‘Osteoporose’, ‘Beroerte’ en ‘Ziekte van Parkinson’.
DOCUMENT
The six-minute walking test (6MWT) may be a practical test for the evaluation functional exercise capacity in children with end-stage renal disease (ESRD). The aim of this study was to investigate the 6MWT performance in children with ESRD compared to reference values obtained in healthy children and, secondly, to study the relationship between 6MWT performance with anthropometric variables, clinical parameters, aerobic capacity and muscle strength. Twenty patients (13 boys and seven girls; mean age 14.1 ± 3.4 years) on dialysis participated in this study. Anthropometrics were taken in a standardized manner. The 6MWT was performed in a 20-m-long track in a straight hallway. Aerobic fitness was measured using a cycle ergometer test to determine peak oxygen uptake (V⋅O2peak)(V⋅O2peak), peak rate (Wpeak) and ventilatory threshold (VT). Muscle strength was measured using hand-held myometry. Children with ESRD showed a reduced 6MWT performance (83% of predicted, p < 0.0001), irrespective of the reference values used. The strongest predictors of 6MWT performance were haematocrit and height. Regression models explained 59% (haematocrit and height) to 60% (haematocrit) of the variance in 6MWT performance. 6MWT performance was not associated with V⋅O2peakV⋅O2peak, strength, or other anthropometric variables, but it was significantly associated with haematocrit and height. Children with ESRD scored lower on the 6MWT than healthy children. Based on these results, the 6MWT may be a useful instrument for monitoring clinical status in children with ESRD, however it cannot substitute for other fitness tests, such as a progressive exercise test to measure V⋅O2peakV⋅O2peak or muscle strength tests.
DOCUMENT
Background There currently is no field test available for measuring maximal exercise capacity in people with stroke. Objective To determine the feasibility, reproducibility and validity of the Shuttle Test (ST) to measure exercise capacity in people with stroke. Design Longitudinal study design. Setting Rehabilitation department, day care centres from a nursing home and private practices specialized in neuro rehabilitation. Subjects People with subacute or chronic stroke. Interventions A standardized protocol was used to determine feasibility, reproducibility and validity of the 10-meter Shuttle Test (10mST). Main measures Number of shuttles completed, 1stVentilatory Threshold (1stVT). Results The associations of the number of shuttles completed and cardiopulmonary capacity as measured with a portable gas analyser were r > 0.7, confirming good convergent validity in subacute and chronic people with stroke. Criterion validity, however, indicates it is not a valid test for measuring maximal cardiopulmonary capacity (VO2max). Only 60% of participants were able to reach the 1stVT. Higher cardiopulmonary capacity and a higher total score of the lower extremity Motricity Index contributed significantly to a higher number of shuttles walked (p = 0.001). Conclusions The Shuttle Test may be a safe and useful exercise test for people after stroke, but may not be appropriate for use with people who walk slower than 2 km/h or 0.56 m/s.
DOCUMENT
The use of measurement instruments has become a major issue in physical therapy, but their use in daily practice is infrequent. The aims of this case report were to develop and evaluate a plan for the systematic implementation of two measurement instruments frequently recommended in Dutch physical therapy clinical guidelines: the Patient-Specific Complaints instrument and the Six-Minute Walk Test.
DOCUMENT
Objective: Despite the common occurrence of lower levels of physical activity and physical fitness in youth with spina bifida (SB) who use a wheelchair, there are very few tests available to measure and assess these levels. The purpose of this study was to determine reliability and the physiologic response of the 6-minute push test (6MPT) in youth with SB who self-propel a wheelchair. Methods: In this reliability and observational study, a sample of 53 youth with SB (5-19 years old; mean age = 13 years 7 months; 32 boys and 21 girls) who used a wheelchair performed 2 exercise tests: the 6MPT and shuttle ride test. Heart rate, minute ventilation, respiratory exchange ratio, and oxygen consumption were measured using a calibrated mobile gas analysis system and a heart rate monitor. For reliability, intraclass correlation coefficients (ICCs), SE of measurement, smallest detectable change for total covered distance, minute work, and heart rate were calculated. Physiologic response during the 6MPT was expressed as percentage of maximal values achieved during the shuttle ride test. Results: The ICCs for total distance and minute work were excellent (0.95 and 0.97, respectively), and the ICC for heart rate was good (0.81). The physiologic response during the 6MPT was 85% to 89% of maximal values, except for minute ventilation (70.6%). Conclusions: For most youth with SB who use a wheelchair for mobility or sports participation, the 6MPT is a reliable, functional performance test on a vigorous level of exercise. Impact: This is the first study to investigate physiologic response during the 6MPT in youth (with SB) who are wheelchair using. Clinicians can use the 6MPT to evaluate functional performance and help design effective exercise programs for youth with SB who are wheelchair using. Keywords: 6-minute push test; adolescent; disabled children; spinal diseases; wheelchairs.
DOCUMENT
Background The purpose of this study is to describe feasibility and test–retest reliability of the six-minute walking distance test (6MWD) and an adapted shuttle run test (aSRT) in persons with severe intellectual and sensory (multiple) disabilities. Materials and Methods Forty-seven persons with severe multiple disabilities, with Gross Motor Function Classification System (GMFCS) grade I and II and wearing a heart rate monitor, performed the 6MWD and the aSRT twice. Results Ninety-six per cent of the participants completed both tests successfully. Wilcoxon signed-rank test revealed no significant differences between test and retest (P < 0.05). Intraclass correlation coefficients for all variables were ≥0.90. Limits of agreement for aSRT in GMFCS II subjects were insufficient. Conclusion Six-minute walking distance test is feasible and reliable for measuring functional exercise capacity in GMFCS I and II participants with severe multiple disabilities. aSRT is feasible and reliable for measuring aerobic capacity in GMFCS I participants. Compared with others, participants with severe multiple disabilities achieved poor results in 6MWD.