Mild steel is relatively low-cost and easily accessible material to fabricate some structural members. It would be a significant advantage if seismic energy dissipaters that are used in structures constructed in the earthquake prone areas, could also be produced on site. In this paper, a promising seismic energy dissipater made of mild steel, so-called steel cushion (SC) is presented. It is provided experimental and analytical responses of SCs subjected to bi-axial loadings. SC rolls under the lateral loading that allows relocation of the plasticized cross-section. Henceforth, SC dissipates considerable amount of seismic energy. A series of tests were performed to achieve experimentally the behavior of SC subjected to longitudinal and transversal loading. Finite Element Models (FEMs) were also generated to reproduce the experimental backbone curves and to predict the bi-directional response properties for discrete transversal forces and plate thicknesses. Closed-form equations were derived to determine yield and ultimate forces and the corresponding displacements as well as location of the plasticized sections. The behavior of SC could either be projected by the FEMs with the exhibited parameters or by means of the proposed closed-form equations and the normalized design chart.
LINK
Energy dissipative steel cushions (EDSCs) are simple units that can be used to join structural members. They can absorb a substantial amount of seismic energy due to their geometric shapes and the ductile behavior of mild steel. Large deformation capability and stable hysteretic behavior were obtained in monotonic and cyclic tests of EDSCs in the framework of the SAFECLADDING project. Discrete numerical modeling strategies were applied to reproduce the experimental results. The first and second models comprise two-dimensional shell elements and one-dimensional flexural frame elements, respectively. The uncertain points in the preparation of the models included the mesh density, representation of the material properties, and interaction between contacting surfaces. A zero-length nonlinear link element was used in the third attempt in the numerical modeling. Parameters are recommended for the Ramberg–Osgood and bilinear models. The obtained results indicate that all of the numerical models can reproduce the response, and the stiffness, strength, and unloading and reloading curves were fitted accurately.
DOCUMENT
Background To gain insight into the role of plantar intrinsic foot muscles in fall-related gait parameters in older adults, it is fundamental to assess foot muscles separately. Ultrasonography is considered a promising instrument to quantify the strength capacity of individual muscles by assessing their morphology. The main goal of this study was to investigate the intra-assessor reliability and measurement error for ultrasound measures for the morphology of selected foot muscles and the plantar fascia in older adults using a tablet-based device. The secondary aim was to compare the measurement error between older and younger adults and between two different ultrasound machines. Methods Ultrasound images of selected foot muscles and the plantar fascia were collected in younger and older adults by a single operator, intensively trained in scanning the foot muscles, on two occasions, 1–8 days apart, using a tablet-based and a mainframe system. The intra-assessor reliability and standard error of measurement for the cross-sectional area and/or thickness were assessed by analysis of variance. The error variance was statistically compared across age groups and machines. Results Eighteen physically active older adults (mean age 73.8 (SD: 4.9) years) and ten younger adults (mean age 21.9 (SD: 1.8) years) participated in the study. In older adults, the standard error of measurement ranged from 2.8 to 11.9%. The ICC ranged from 0.57 to 0.97, but was excellent in most cases. The error variance for six morphology measures was statistically smaller in younger adults, but was small in older adults as well. When different error variances were observed across machines, overall, the tablet-based device showed superior repeatability. Conclusions This intra-assessor reliability study showed that a tablet-based ultrasound machine can be reliably used to assess the morphology of selected foot muscles in older adults, with the exception of plantar fascia thickness. Although the measurement errors were sometimes smaller in younger adults, they seem adequate in older adults to detect group mean hypertrophy as a response to training. A tablet-based ultrasound device seems to be a reliable alternative to a mainframe system. This advocates its use when foot muscle morphology in older adults is of interest.
MULTIFILE