Storm sewers are known to significantly contribute to annual pollutant loads to receiving water bodies. The storm sewers of the city of Almere discharge the stormwater of 1384 ha of impervious area via 700 storm sewer outfalls (SSOs) to the local receiving water system. This water system suffers from eutrophication and long term build-up of pollutant levels in the sediment bed. In order to be able to select the most effective stormwater management strategy, the municipality of Almere and Water Authority Zuiderzeeland have launched a 2 year extensive monitoring project to measure the stormwater quality and the potential impact of source control and end of pipe measures to decrease the emission via SSOs. Source control measures, such as removal of illicit connections and increasing the cleaning frequency of gully pots showed to be most effective. The potential impact of end of pipesolutions based on settling showed to be very limited due to the low settleability of solids in the storm water of Almere at the SSOs.
DOCUMENT
Sedimentation devices have been widely implemented to remove suspended solids and attached pollutants from stormwater before entering surface waters. The treatment performance of these best management practices (BMPs) on fine particles is rarely investigated in a standardized way. To overcome this information gap a reliable and standardized testing procedure is formulated.Four devices have been tested on their suspended sediments removal efficiency at different discharges and particle sizes, using the newly developed standardized full scale test method. The observed removal rates of the facilities with a storage volume in the order of 1.5 m3 and settling surface around 1 m2 drop to low removal efficiencies at flow rates of 10 l/s or more. For small sized sediments (up to 63 μm) the removal efficiency is below 50%. The results of the experiments can be used to improve both the design and the dimensions of stormwater treatment devices.
LINK
Objective: In myocardial perfusion single-photon emission computed tomography (SPECT), abdominal activity often interferes with the evaluation of perfusion in the inferior wall, especially after pharmacological stress. In this randomized study, we examined the effect of carbonated water intake versus still water intake on the quality of images obtained during myocardial perfusion images (MPI) studies. Methods: A total of 467 MIBI studies were randomized into a carbonated water group and a water group. The presence of intestinal activity adjacent to the inferior wall was evaluated by two observers. Furthermore, a semiquantitative analysis was performed in the adenosine subgroup,using a count ratio of the inferior myocardial wall and adjacent abdominal activity. Results: The need for repeated SPECT in the adenosine studies was 5.3 % in the carbonated water group versus 19.4 % in the still water group (p = 0.019). The inferior wall-to-abdomen count ratio was significantly higher in the carbonated water group compared to the still water group (2.11 ± 1.00 vs. 1.72 ± 0.73, p\0.001). The effect of carbonated water during rest and after exercise was not significant. Conclusions: This randomized study showed that carbonated water significantly reduced the interference of extra-cardiac activity in adenosine SPECT MPI. Keywords: Extra-cardiac radioactivity, Myocardial SPECT, Image quality enhancement, Carbonated water
DOCUMENT