Onderzoek van het RIVM laat zien dat afdelingen radiologie daadwerkelijk behoefte hebben aan meer DRN's
Introduction: The Netherlands does not have a national guideline for performing radiographic examinations on pregnant patients. Radiographic examination is a generic term for all examinations performed using ionizing radiation, including but not limited to radiographs, fluoroscopy and computed tomography. A pilot study amongst radiographers (Medical Radiation Technologists (MRTs)) showed that standardized practice of radiographic examinations on pregnant women is not evident between Radiology departments and that there is a need for a national guideline as the varying practice methods may lead to confusion and uncertainty amongst both patients and MRTs. Methods: Focus groups consisting of MRTs from several Radiology departments within the Netherlands were used to map ideas and requirements as to what should be included in the national guideline. Nine focus group sessions were organized with a total of 52 participants. Using a previous review (Wit, Fleur; Vroonland, Colinda; Bijwaard H. Pre-natal X-ray exposure and the risk of developing paediatric cancer; a systematic review of risk factors and a comparison of international guidelines. Health Physics 2021; 121 (3):225e233), the following key points were chosen as discussion topics for the focus group sessions: dose reduction, confirming pregnancy and risk communication. Results: Results showed that the participating MRTs did not agree on the use of lead aprons. That the national guideline should include standardized methods to adjust parameters to decrease radiation dose. Focus group participants find it difficult to ask a patient's pregnancy status, especially when dealing with relatively young and old (er) patients. When communicating the level of risk associated with a radiographic examination the participating MRTs would like to be able to use examples and comparisons, preferably by means of a multilingual website. Conclusion: A national guideline must include information on justification, available alternatives, dose reductions methods and confirmation of pregnancy requirements when fetal dose is a significant risk. Implications for practice: A national guideline ensures standardized practice can be implemented in Radiology departments, increasing clarity of the issues for both patients and MRTs.
Voor patiënten die radiologische verrichtingen ondergaan bestaan geen dosislimieten, maar wel zogenaamde Diagnostische ReferentieNiveaus (DRN’s). Dit zijn richtwaarden voor de hoeveelheid straling voor de gemiddelde patiënt bij goede praktijkvoering. In Nederland bestaan nationale DRN’s voor slechts 11 radiologische verrichtingen. In andere Europese landen zijn dat er vaak beduidend meer. Zo ontbreken in Nederland DRN’s voor interventie-radiologische verrichtingen (interventies), terwijl dit juist verrichtingen zijn waarbij vaak relatief hoge stralingsdoses worden uitgedeeld. In deze studie, die gebaseerd is op het afstudeerwerk van twee van de auteurs (GH en MtS), is als proof-of-principle een lokaal DRN afgeleid uit data van een enkel ziekenhuis (het Dijklander ziekenhuis). Voor dit lokale DRN is data verzameld van percutane transluminale angioplastiek (PTA) in de arteria femoralis superficialis (AFS), uitgevoerd met dezelfde apparatuur in één angiografiekamer door twee radiologen. In totaal zijn daarbij 52 complicatievrije interventies geïncludeerd. Uit de verzamelde data is als 75 percentielwaarde een lokaal DRN voor PTA van de AFS afgeleid van 50,9 Gy*cm2. Dit is ruim 20 Gy*cm2 lager dan gevonden in twee andere Europese studies. In die studies werd daarentegen wel veel meer data geïncludeerd van verschillende radiologie-afdelingen. Deze studie laat zien dat het ook in Nederland mogelijk is om voor een interventie een DRN op te stellen. Het verdient de aanbeveling deze studie te herhalen of uit te breiden met data van diverse andere Nederlandse ziekenhuizen om zodoende een nationaal DRN te bepalenn