Point of Care Diagnostics and Technology Adoption in Homecare, Clinical Care, and Emergency Care


Beschrijving

Personal factors, team factors, and organizational factors have a strong influence on the adoption of technology used by, for instance, nurses in homecare. This part of the research portfolio in Point of Care Diagnostics regards the adoption of diagnostic technology in the health care domain.


Producten

    product

    Use of infrared thermography in the detection of superficial phlebitis in adult intensive care unit patients

    Common methods to detect phlebitis may not be sufficient for patients in the intensive care unit (ICU). The goal of this study was to investigate the feasibility of infrared (IR) thermography to objectively detect phlebitis in adult ICU patients. We included a total of 128 adult ICU-patients in a pilot and subsequent validation study. Median [interquartile range] age was 62 [54-71] years and 88 (69%) patients were male. Severity of phlebitis was scored using the visual infusion phlebitis (VIP)-score, ranging from 0 (no phlebitis) to 5 (thrombophlebitis). The temperature difference (ΔT) between the insertion site and a proximal reference point was measured with IR thermography. In 78 (34%) catheters early phlebitis and onset of moderate phlebitis was observed (VIP-score of 1-3). In both the pilot and the validation study groups ΔT was significantly higher when the VIP-score was ≥1 compared to a VIP-score of 0 (p<0.01 and p<0.001, respectively). Multivariate analysis identified ΔT (p<0.001) and peripheral venous catheter (PVC) dwell time (p = 0.001) as significantly associated with phlebitis. IR thermography may be a promising technique to identify phlebitis in the ICU. An increased ΔT as determined with thermography may be a risk factor for phlebitis.

    PDF

    product

    Temporal artery temperature measurements versus bladder temperature in critically ill patients, a prospective observational study

    Purpose: Accurate measurement of body temperature is important for the timely detection of fever or hypothermia in critically ill patients. In this prospective study, we evaluated whether the agreement between temperature measurements obtained with TAT (test method) and bladder catheter-derived temperature measurements (BT; reference method) is sufficient for clinical practice in critically ill patients. Methods: Patients acutely admitted to the Intensive Care Unit were included. After BT was recorded TAT measurements were performed by two independent researchers (TAT1; TAT2). The agreement between TAT and BT was assessed using Bland-Altman plots. Clinical acceptable limits of agreement (LOA) were defined a priori (<0.5°C). Subgroup analysis was performed in patients receiving norepinephrine. Results: In total, 90 critically ill patients (64 males; mean age 62 years) were included. The observed mean difference (TAT-BT; ±SD, 95% LOA) between TAT and BT was 0.12°C (-1.08°C to +1.32°C) for TAT1 and 0.14°C (-1.05°C to +1.33°C) for TAT2. 36% (TAT1) and 42% (TAT2) of all paired measurements failed to meet the acceptable LOA of 0.5°C. Subgroup analysis showed that when patients were receiving intravenous norepinephrine, the measurements of the test method deviated more from the reference method (p = NS). Conclusion: The TAT is not sufficient for clinical practice in critically ill adults

    LINK