The 5th generation of mobile communications is designed to employ both FR1 and FR2 bands throughout the world. The higher frequency bands (i.e., FR2 n257 26.50 - 29.50 GHz) are posing several challenges to operators and national telecom agencies for performing electromagnetic fields (EMF) measurements. In this work we present the design and preliminary evaluation of an FR2 sensor node to measure EMF radiations in urban environments. The design is carried out in an RF circuit design software, i.e., Keysight ADS, where the various nonidealities (i.e., nonlinearities, noise behavior and electromagnetic response) of the various sub blocks of the systems are accounted for. The sensor concept is then implemented in a prototype board technology (i.e., X-microwave) and its response is experimentally verified in the FR2 band.
DOCUMENT
from the article: The demand for a wireless CO2 solution is ever increasing. One of the biggest problems with the majority of commercial available CO2 sensors is the high energy consumption which makes them unsuitable for battery operation. Possible candidates for CO2 sensing in a low power wireless application are very limited and show a problematic calibration process. This study focuses on one of those EMF candidates, which is a Ag4RbI5 based sensor. This EMF sensor is based on the potentiometric principle and consumes no energy. The EMF cell was studied in a chamber where humidity, temperature and CO2 level could be controlled. This study gives an detailed insight in the different drift properties of the potentiometric CO2 sensor and a method to amplify the sensors signal. Furthermore, a method to minimize the several types of drift is given. With this method the temperature drift can be decreased by a factor 10, making the sensor a possible candidate for a wireless CO2 sensor network.
DOCUMENT
A low-cost sensornode is introduced to monitor the 5G EMF exposure in the Netherlands for the four FR1 frequency bands. The sensornode is validated with in-lab measurements both with CW signals as for QAM signals and perform for both cases and for all frequency bands an error less than 1 dB for a dynamic range of 40 dB. This sensor is a follow up of the earlier version of our previously developed sensor and have substantial improvements in terms of linearity, error, and stability.
DOCUMENT
This review offers a detailed examination of the current landscape of radio frequency (RF) electromagnetic field (EMF) assessment tools, ranging from spectrum analyzers and broadband field meters to area monitors and custom-built devices. The discussion encompasses both standardized and non-standardized measurement protocols, shedding light on the various methods employed in this domain. Furthermore, the review highlights the prevalent use of mobile apps for characterizing 5G NR radio network data. A growing need for low-cost measurement devices is observed, commonly referred to as “sensors” or “sensor nodes”, that are capable of enduring diverse environmental conditions. These sensors play a crucial role in both microenvironmental surveys and individual exposures, enabling stationary, mobile, and personal exposure assessments based on body-worn sensors, across wider geographical areas. This review revealed a notable need for cost-effective and long-lasting sensors, whether for individual exposure assessments, mobile (vehicle-integrated) measurements, or incorporation into distributed sensor networks. However, there is a lack of comprehensive information on existing custom-developed RF-EMF measurement tools, especially in terms of measuring uncertainty. Additionally, there is a need for real-time, fast-sampling solutions to understand the highly irregular temporal variations EMF distribution in next-generation networks. Given the diversity of tools and methods, a comprehensive comparison is crucial to determine the necessary statistical tools for aggregating the available measurement data.
MULTIFILE
The European Union (EU) Horizon Europe project NextGEM provides a framework for generating health-relevant scientific knowledge and data on new exposure scenarios to Radio-Frequency Electromagnetic Fields (RF-EMFs) and developing and validating tools for evidence-based risk assessment. Practical guidelines for different societal stakeholders for RF-EMF exposure awareness and preventive actions will be created. This abstract outlines the goals of these guidelines, the definitions used to keep the guidelines specific and practical and the procedure that will ultimately generate the guidelines.
DOCUMENT
The evolution of emerging technologies that use Radio Frequency Electromagnetic Field (RF-EMF) has increased the interest of the scientific community and society regarding the possible adverse effects on human health and the environment. This article provides NextGEM’s vision to assure safety for EU citizens when employing existing and future EMF-based telecommunication technologies. This is accomplished by generating relevant knowledge that ascertains appropriate prevention and control/actuation actions regarding RF-EMF exposure in residential, public, and occupational settings. Fulfilling this vision, NextGEM commits to the need for a healthy living and working environment under safe RF-EMF exposure conditions that can be trusted by people and be in line with the regulations and laws developed by public authorities. NextGEM provides a framework for generating health-relevant scientific knowledge and data on new scenarios of exposure to RF-EMF in multiple frequency bands and developing and validating tools for evidence-based risk assessment. Finally, NextGEM’s Innovation and Knowledge Hub (NIKH) will offer a standardized way for European regulatory authorities and the scientific community to store and assess project outcomes and provide access to findable, accessible, interoperable, and reusable (FAIR) data.
DOCUMENT
Background: Everyday exposure to radiofrequency electromagnetic fields (RF-EMF) emitted from wireless devices such as mobile phones and base stations, radio and television transmitters is ubiquitous. Some people attribute non-specific physical symptoms (NSPS) such as headache and fatigue to exposure to RF-EMF. Most previous laboratory studies or studies that analyzed populations at a group level did not find evidence of an association between RF-EMF exposure and NSPS. Objectives: We explored the association between exposure to RF-EMF in daily life and the occurrence of NSPS in individual self-declared electro hypersensitive persons using body worn exposimeters and electronic diaries. Methods: We selected seven individuals who attributed their NSPS to RF-EMF exposure. The level of and variability in personal RF-EMF exposure and NSPS were determined during a three-week period. Data were analyzed using timeseries analysis in which exposure as measured and recorded in the diary was correlated with NSPS. Results: We found statistically significant correlations between perceived and actual exposure to wireless internet (WiFi - rate of change and number of peaks above threshold) and base stations for mobile telecommunications (GSM+UMTS downlink, rate of change) and NSPS scores in four of the seven participants. In two persons a higher EMF exposure was associated with higher symptom scores, and in two other persons it was associated with lower scores. Remarkably, we found no significant correlations between NSPS and timeweighted average power density, the most commonly used exposure metric. Conclusions: RF-EMFexposure was associated either positively or negatively with NSP Sinsome but not all of the selected self-declared electro hypersensitive persons. https://doi.org/10.1016/j.envint.2018.08.064
MULTIFILE
With this contribution, the results of the measurement campaign performed with a synchronously distributed antenna array testbed operating at the center frequency of 3.686 GHz are presented. For the first time, to the best of the authors’ knowledge, the electric field distribution induced by coherent downlink transmission was experimentally assessed in the proximity of the target receiver using a calibrated electromagnetic field probe. This allowed to quantify the actual observed electric field gain and the shape of the electric field enhancement region around the target received. It was found that 16 transmitting antenna elements enhance the root-mean-square electric field level by about a factor of two, in a 2.5λ neighborhood of the target receiver. In addition, a possible disruption of the propagation environment due to the probe movement was assessed through the real-time channel state information feedback.
DOCUMENT
This paper compares different low-cost sensors that can measure (5G) RF-EMF exposure. The sensors are either commercially available (off-the-shelf Software Defined Radio (SDR) Adalm Pluto) or constructed by a research institution (i.e., imec-WAVES, Ghent University and Smart Sensor Systems research group (S3R), The Hague University of Applied Sciences). Both in-lab (GTEM cell) and in-situ measurements have been performed for this comparison. The in-lab measurements tested the linearity and sensitivity, which can then be used to calibrate the sensors. The in-situ testing confirmed that the low-cost hardware sensors and SDR can be used to assess the RF-EMF radiation. The variability between the sensors was 1.78 dB on average, with a maximum deviation of 5.26 dB. Values between 0.09 V/m and 2.44 V/m were obtained at a distance of about 50 m from the base station. These devices can be used to provide the general public and governments with temporal and spatial 5G electromagnetic field values.
DOCUMENT
In this work, in situ measurements of the radio frequency electromagnetic field exposure have been conducted for an indoor massive MIMO 5G base station operating at 26–28 GHz. Measurements were performed at six different positions (at distances between 9.94 and 14.32 m from the base station), of which four were in line-of-sight and two were in non-line-of-sight. A comparison was performed between the measurements conducted with an omnidirectional probe and with a horn antenna, for scenarios with and without a user equipment used to actively create an antenna traffic beam from the base station towards the measurement location. A maximum exposure of 171.9 mW/m2 was measured at a distance of 9.94 m from the base station. This is below 2% of the ICNIRP reference level. Moreover, the feasibility to measure the power per resource element of the Synchronization Signal Block - which can be used to extrapolate the maximum exposure level - with a conventional spectrum analyzer was shown by comparison with a network decoder.
MULTIFILE