With the increased adoption of real-time objective measurements of player experience, advances have been made in characterising the dynamically changing aspects of the player experience during gameplay itself. A direct coupling to player action, however, is not without challenges. Many physiological responses, for instance, have an inherent delay, and often take some time to return to a baseline, providing challenges of interpretation when analysing rapidly changing gameplay on a micro level of interaction. The development of event-related, or phasic, measurements directly coupled to player actions provides additional insights, for instance through player modelling, but also through the use of behavioural characteristics of the human computer interaction itself. In this study, we focused on the latter, and measured keyboard pressure in a number of different, fast-paced action games. In this particular case, we related specific functional game actions (keyboard presses) to experiential player behaviour. We found keyboard pressure to be higher for avoidance as compared to approach-oriented actions. Additionally, the difference between avoidance and approach keyboard pressure related to levels of arousal. The findings illustrate the application potential of qualifying players’ functional actions at play (navigating in a game) and interpret player experience related to these actions through players’ real world behavioural characteristics like interface pressure.
MULTIFILE
BackgroundOcclusions of intravenous (IV) tubing can prevent vital and time-critical medication or solutions from being delivered into the bloodstream of patients receiving IV therapy. At low flow rates (≤ 1 ml/h) the alarm delay (time to an alert to the user) can be up to 2 h using conventional pressure threshold algorithms. In order to reduce alarm delays we developed and evaluated the performance of two new real-time occlusion detection algorithms and one co-occlusion detector that determines the correlation in trends in pressure changes for multiple pumps.MethodsBench-tested experimental runs were recorded in triplicate at rates of 1, 2, 4, 8, 16, and 32 ml/h. Each run consisted of 10 min of non-occluded infusion followed by a period of occluded infusion of 10 min or until a conventional occlusion alarm at 400 mmHg occurred. The first algorithm based on binary logistic regression attempts to detect occlusions based on the pump’s administration rate Q(t) and pressure sensor readings P(t). The second algorithm continuously monitored whether the actual variation in the pressure exceeded a threshold of 2 standard deviations (SD) above the baseline pressure. When a pump detected an occlusion using the SD algorithm, a third algorithm correlated the pressures of multiple pumps to detect the presence of a shared occlusion. The algorithms were evaluated using 6 bench-tested baseline single-pump occlusion scenarios, 9 single-pump validation scenarios and 7 multi-pump co-occlusion scenarios (i.e. with flow rates of 1 + 1, 1 + 2, 1 + 4, 1 + 8, 1 + 16, and 1 + 32 ml/h respectively). Alarm delay was the primary performance measure.ResultsIn the baseline single-pump occlusion scenarios, the overall mean ± SD alarm delay of the regression and SD algorithms were 1.8 ± 0.8 min and 0.4 ± 0.2 min, respectively. Compared to the delay of the conventional alarm this corresponds to a mean time reduction of 76% (P = 0.003) and 95% (P = 0.001), respectively. In the validation scenarios the overall mean ± SD alarm delay of the regression and SD algorithms were respectively 1.8 ± 1.6 min and 0.3 ± 0.2 min, corresponding to a mean time reduction of 77% and 95%. In the multi-pump scenarios a correlation > 0.8 between multiple pump pressures after initial occlusion detection by the SD algorithm had a mean ± SD alarm delay of 0.4 ± 0.2 min. In 2 out of the 9 validation scenarios an occlusion was not detected by the regression algorithm before a conventional occlusion alarm occurred. Otherwise no occlusions were missed.ConclusionsIn single pumps, both the regression and SD algorithm considerably reduced alarm delay compared to conventional pressure limit-based detection. The SD algorithm appeared to be more robust than the regression algorithm. For multiple pumps the correlation algorithm reliably detected co-occlusions. The latter may be used to localize the segment of tubing in which the occlusion occurs.
LINK
Objective. In this study an experimental set-up for measuring skin microvascular responses of the footsole to changes in externally applied pressure was analysed. Design. A clinical study. Skin microvascular blood flow was measured in healthy volunteers, during and after external mechanical pressure of different magnitudes. Background. During standing and walking the footsole is commonly exposed to high static and dynamic mechanical pressure, resulting in changes in the microcirculation of the footsole. In diabetic patients a disturbed interaction between externally applied pressure and skin microvascular response seems to be involved in the development of a foot ulcer. Methods. Eleven volunteers participated in the study. Static loads were applied to the heel part of the footsole with the person in a supine position. Contact pressure and skin blood flux, based on the laser Doppler technique, were simultaneously monitored. The pressure used was varied in five discrete steps between 10 and 160 kPa and applied during a period of 5 min each. The microcirculation was measured during as well as after pressure loading. Results. Pressures of 40 kPa and higher do stop the blood flow in the skin micro-circulation. Releasing the applied pressure resulted in a hyperaemic response. This response appears to increase in amplitude at increasing pressures up to 800% of the baseline laser Doppler fluxmetry level. Beyond a pressure level of 80 kPa the hyperaemic response seems not to be influenced by the pressure level. The time needed to achieve the maximal laser Doppler fluxmetry level decreased when the pressure was raised from 10 to 80 kPa, but increased again when higher pressures were applied (P = 0.051). An intra-individual variation of 11-50% was observed for the parameters describing the blood flux before, during, and after pressure application. Conclusion. Simultaneously measuring changes in contact pressure and laser Doppler flux of the footsole is a useful method to study the interaction of external mechanical pressure and skin microvascular reactions. Pressures above 40 kPa stop skin microvascular blood flow. Releasing the applied pressure results in a hyperaemic response, which increases when the applied pressure increases from 40 to 80 kPa. Higher pressures do not influence the amplitude in skin microvascular response, but result in a longer delay to maximal hyperaemia.
DOCUMENT
This project is part of an interdisciplinary and international collaboration bringing together experts in nanomaterials, sensor technology, and engineering from the University of Technology of Troyes (UTT, France), Eindhoven University of Technology (TU/e, The Netherlands) and Hanze University of Applied Sciences (HUAS, The Netherlands). It presents an innovative, integrated approach including design, fabrication, characterization, and integration of flexible sensors dedicated to wind turbine blade monitoring, aiming to advance smart monitoring and renewable energy research. The sensor will be developed using functional polymer films decorated with conductive nanoparticles. A novel manufacturing approach will be applied, combining additive manufacturing techniques with the colloidal deposition of silver or gold nanoparticles.
Many cities and regions that are faced with growing tourism are looking for tools that can help them manage visitors and visitor flows and the consequent impacts on liveability. In this process, it is of crucial importance to have an as accurate and real-time (or predictive) as possible insight into visitor volumes, visitor flows and visitor impacts, as well as an insight into perceptions and sentiments among both visitors and residents.In the tools already available for this purpose, very limited use of (big) data is made. Although these sources may potentially offer many useful insights, accessing them or using them effectively turns out to be difficult due to a lack of understanding of the (im)possibilities of data, the practical requirements and the costs.In this project we want to obtain an insight into the measurement methods that are available in order to develop tourism policy in Etten-Leur on the basis of the insights to be gained from the data. With this approach, the research partners aim to develop a dashboard that can also be used in other situations, nationally and internationally.Partners: VisitBrabant, Van Gogh Sites Foundation, Van Gogh Kerk Etten-Leur, Gemeente Etten-Leur.