BackgroundPatients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.MethodsTo determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.ResultsIn both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.ConclusionsModified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.
MULTIFILE
OBJECTIVE: To investigate the level of agreement of the behavioural mapping method with an accelerometer to measure physical activity of hospitalized patients. DESIGN: A prospective single-centre observational study. SETTING: A university medical centre in the Netherlands. SUBJECTS: Patients admitted to the hospital. MAIN MEASURES: Physical activity of participants was measured for one day from 9 AM to 4 PM with the behavioural mapping method and an accelerometer simultaneously. The level of agreement between the percentages spent lying, sitting and moving from both measures was evaluated using the Bland-Altman method and by calculating Intraclass Correlation Coefficients. RESULTS: In total, 30 patients were included. Mean (±SD) age was 63.0 (16.8) years and the majority of patients were men (n = 18). The mean percentage of time (SD) spent lying was 47.2 (23.3) and 49.7 (29.8); sitting 42.6 (20.5) and 40.0 (26.2); and active 10.2 (6.1) and 10.3 (8.3) according to the accelerometer and observations, respectively. The Intraclass Correlation Coefficient and mean difference (SD) between the two measures were 0.852 and -2.56 (19.33) for lying; 0.836 and 2.60 (17.72) for sitting; and 0.782 and -0.065 (6.23) for moving. The mean difference between the two measures is small (⩽2.6%) for all three physical activity levels. On patient level, the variation between both measures is large with differences above and below the mean of ⩾20% being common. CONCLUSION: The overall level of agreement between the behavioural mapping method and an accelerometer to identify the physical activity levels 'lying', 'sitting' and 'moving' of hospitalized patients is reasonable.
DOCUMENT
Background. Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDICAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. Objective. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. Design. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. Methods. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean4.5 days). Pearson’s r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. Results. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were .57 and .53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. Limitations. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. Conclusions. The Dutch LLFDI-CAT showed strong validity and high reliability when used to assess physical function and disability in older adults dwelling in the community.
MULTIFILE
Background: The aging population is increasingly faced with daily life limitations, threatening their Functional Independence (FI). These limitations extend different life domains and require a broad range of community-care professionals to be addressed. The Decision Support Tool for Functional Independence (DST-FI) facilitates community-care professionals in providing uncontradictory recommendations regarding the maintenance of FI in community-dwelling older people. The current study aims to determine the validity and reliability of the DST-FI. Methods: Sixty community-care professionals completed a twofold assessment. To assess construct validity, participants were asked to assign predefined recommendations to fifty cases of older people to maintain their level of FI. Hypotheses were tested regarding the expected recommendations per case. Content validity was assessed by questions on relevance, comprehensiveness, and comprehensibility of the current set of recommendations. Twelve participants repeated the assessment after two weeks to enable both within- and between rater reliability properties, expressed by an Intraclass Correlation Coefficient. Results: Seven out of eight predefined hypotheses confirmed expectations, indicating high construct validity. As the recommendations were indicated 'relevant' and 'complete', content validity was high as well. Agreement between raters was poor to moderate while agreement within raters was moderate to excellent, resulting in moderate overall reliability. Conclusion: The DST-FI suggests high validity and moderate reliability properties when used in a population of community-dwelling older people. The tool could facilitate community-care professionals in their task to preserve FI in older people. Future research should focus on psychometric properties like feasibility, acceptability, and developing and piloting strategies for implementation in community-care.
LINK
The Kennedy Axis V is a routine outcome measurement instrument which can assist the assessment of the short-term risk for violence and other adverse patient outcomes. The purpose of this study was to evaluate the interrater reliability and clinical utility of the instrument when used by mental health nurses in daily care of patients with mental illness. This cross-sectional study was conducted in inpatient and outpatient adult psychiatric care units and in one adolescent inpatient unit at a university hospital in the Netherlands. Interrater reliability was measured based on the independent scores of two different nurses for the same patients. The clinical utility of the instrument was evaluated by means of a clinical utility questionnaire. To gain a deeper understanding of rating difficulties at the adolescent unit, additional data were collected in two focus group interviews. The overall results revealed a substantial level of agreement between nurses (intraclass correlation coefficient and Pearson 0.79). Some rating challenges were identified, including difficulties with scoring the instrument and using tailor-made interventions related to the scores. These challenges can be resolved using refined training and implementation strategies. When the Kennedy Axis V is accompanied by a solid implementation strategy in adult mental health care, the instrument can be used for short-term risk assessment and thereby contribute in efforts to reduce violence, suicide, self-harm, severe selfneglect, and enhanced objectivity in clinical decision-making.
DOCUMENT
Validity and Reproducibility of a New Treadmill Protocol: The Fitkids Treadmill Test. Med. Sci. Sports Exerc., Vol. 47, No. 10, pp. 2241–2247, 2015. Purpose: This study aimed to investigate the validity and reproducibility of a new treadmill protocol in healthy children and adolescents: the Fitkids Treadmill Test (FTT). Methods: Sixty-eight healthy children and adolescents (6–18 yr) were randomly divided into a validity group (14 boys and 20 girls; mean T SD age, 12.9 T 3.6 yr) that performed the FTT and Bruce protocol, both with respiratory gas analysis within 2 wk, and a reproducibility group (19 boys and 15 girls; mean T SD age, 13.5 T 3.5 yr) that performed the FTT twice within 2 wk. A subgroup of 21 participants within the reproducibility group performed both FTT with respiratory gas analysis. Time to exhaustion (TTE) was the main outcome of the FTT. Results: V˙ O2peak measured during the FTT showed excellent correlation with V˙ O2peak measured during the Bruce protocol (r = 0.90; P G 0.01). Backward multiple regression analysis provided the following prediction equations for V˙ O2peak (LIminj1) for boys and girls, respectively: V˙ O2peak FTT ¼ j0:748 þ ð0:117 TTEFTTÞ þ ð0:032 bodymassÞ þ 0:263, and V˙ O2peak FTT ¼ j0:748 þ ð0:117 TTEFTTÞ þ ð0:032 bodymassÞ [R2 ¼ 0:935; SEE ¼ 0:256LI min j1]. Cross-validation of the regression model showed an R2 value of 0.76. Reliability statistics for the FTT showed an intraclass correlation coefficient of 0.985 (95% confidence interval, 0.971–0.993; P G 0.001) for TTE. Bland–Altman analysis showed a mean bias of j0.07 min, with limits of agreement between +1.30 and j1.43 min. Conclusions: Results suggest that the FTT is a useful treadmill protocol with good validity and reproducibility in healthy children and adolescents. Exercise performance on the FTT and body mass can be used to adequately predict V˙ O2peak when respiratory gas analysis is not available.
DOCUMENT
Objective. There are no Dutch language disease-specific questionnaires for patients with patellofemoral pain syndrome available that could help Dutch physiotherapists to assess and monitor these symptoms and functional limitations. The aim of this study was to translate the original disease-specific Kujala Patellofemoral Score into Dutch and evaluate its reliability. Methods. The questionnaire was translated from English into Dutch in accordance with internationally recommended guidelines. Reliability was determined in 50 stable subjects with an interval of 1 week. The patient inclusion criteria were age between 14 and 60 years; knowledge of the Dutch language; and the presence of at least three of the following symptoms: pain while taking the stairs, pain when squatting, pain when running, pain when cycling, pain when sitting with knees flexed for a prolonged period, grinding of the patella and a positive clinical patella test. The internal consistency, test–retest reliability, measurement error and limits of agreement were calculated. Results. Internal consistency was 0.78 for the first assessment and 0.80 for the second assessment. The intraclass correlation coefficient (ICCagreement) between the first and second assessments was 0.98. The mean difference between the first and second measurements was 0.64, and standard deviation was 5.51. The standard error measurement was 3.9, and the smallest detectable change was 11. The Bland and Altman plot shows that the limits of agreement are 10.37 and 11.65. Conclusions. The results of the present study indicated that the test–retest reliability translated Dutch version of the Kujala Patellofemoral Score questionnaire is equivalent of the test– retest original English language version and has good internal consistency. Trial registration NTR (TC = 3258). Copyright © 2015 John Wiley & Sons, Ltd.
DOCUMENT
Purpose: The main purpose of the research was to measure reliability and validity of the Scoring Rubric for Information Literacy (Van Helvoort, 2010). Design/methodology/approach: Percentages of agreement and Intraclass Correlation were used to describe interrater reliability. For the determination of construct validity, factor analysis and reliability analysis were used. Criterion validity was calculated with Pearson correlations. Findings: In the described case, the Scoring Rubric for Information Literacy appears to be a reliable and valid instrument for the assessment of information literate performance. Originality/value: Reliability and validity are prerequisites to recommend a rubric for application. The results confirm that this Scoring Rubric for Information Literacy can be used in courses in higher education, not only for assessment purposes but also to foster learning. Oorspronkelijke artikel bij Emerald te vinden bij http://dx.doi.org/10.1108/JD-05-2016-0066
MULTIFILE
To evaluate the construct validity and the inter-rater reliability of the Dutch Activity Measure for Post- Acute Care “6-clicks” Basic Mobility short form measuring the patient’s mobility in Dutch hospital care. First, the “6-clicks” was translated by using a forward-backward translation protocol. Next, 64 patients were assessed by the physiotherapist to determine the validity while being admitted to the Internal Medicine wards of a university medical center. Six hypotheses were tested regarding the construct “mobility” which showed that: Better “6-clicks” scores were related to less restrictive pre-admission living situations (p¼0.011), less restrictive discharge locations (p¼0.001), more independence in activities of daily living (p¼0.001) and less physiotherapy visits (p<0.001). A correlation was found between the “6-clicks” and length of stay (r¼0.408, p¼0.001), but not between the “6-clicks” and age (r¼0.180, p¼0.528). To determine the inter-rater reliability, an additional 50 patients were assessed by pairs of physiotherapists who independently scored the patients. Intraclass Correlation Coefficients of 0.920 (95%CI: 0.828–0.964) were found. The Kappa Coefficients for the individual items ranged from 0.649 (walking stairs) to 0.841 (sit-to-stand). The Dutch “6-clicks” shows a good construct validity and moderate-toexcellent inter-rater reliability when used to assess the mobility of hospitalized patients.
DOCUMENT
Background Testing aerobic fitness in youth is important because of expected relationships with health. Objective The purpose of the study was to estimate the validity and reliability of the Shuttle Ride Test in youth who have spina bifida and use a wheelchair for mobility and sport. Design Ths study is a validity and reliability study. Methods The Shuttle Ride Test, Graded Wheelchair Propulsion Test, and skill-related fitness tests were administered to 33 participants for the validity study (age = 14.5 ± 3.1 y) and to 28 participants for the reliability study (age = 14.7 ± 3.3 y). Results No significant differences were found between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test for most cardiorespiratory responses. Correlations between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test were moderate to high (r = .55–.97). The variance in peak oxygen uptake (VO2peak) could be predicted for 77% of the participants by height, number of shuttles completed, and weight, with large prediction intervals. High correlations were found between number of shuttles completed and skill-related fitness tests (CI = .73 to −.92). Intraclass correlation coefficients were high (.77–.98), with a smallest detectable change of 1.5 for number of shuttles completed and with coefficients of variation of 6.2% and 6.4% for absolute VO2peak and relative VO2peak, respectively. Conclusions When measuring VO2peak directly by using a mobile gas analysis system, the Shuttle Ride Test is highly valid for testing VO2peak in youth who have spina bifida and use a wheelchair for mobility and sport. The outcome measure of number of shuttles represents aerobic fitness and is also highly correlated with both anaerobic performance and agility. It is not possible to predict VO2peak accurately by using the number of shuttles completed. Moreover, the Shuttle Ride Test is highly reliable in youth with spina bifida, with a good smallest detectable change for the number of shuttles completed.
DOCUMENT