Peak oxygen uptake (V'O2peak) is recognised as the best expression of aerobic fitness. Therefore, it is essential that V'O2peak reference values are accurate for interpreting a cardiopulmonary exercise test (CPET). These values are country specific and influenced by underlying biological ageing processes. They are normally stratified per paediatric and adult population, resulting in a discontinuity at the transition point between prediction equations. There are currently no age-related reference values available for the lifespan of individuals in the Dutch population. The aim of this study is to determine the best-fitting regression model for V'O2peak in the healthy Dutch paediatric and adult populations in relation to age. In this retrospective study, CPET cycle ergometry results of 4477 subjects without reported somatic diseases were included (907 females, age 7.9-65.0 years). Generalised additive models were employed to determine the best-fitting regression model. Cross-validation was performed against an independent dataset consisting of 3518 subjects (170 females, age 6.8-59.0 years). An additive model was the best fitting with the largest predictive accuracy in both the primary (adjusted R2=0.57, standard error of the estimate (see)=556.50 mL·min-1) and cross-validation (adjusted R2=0.57, see=473.15 mL·min-1) dataset. This study provides a robust additive regression model for V'O2peak in the Dutch population.
LINK
Background: Patients with Senning repair for complete transposition of the great arteries (d-TGA) show an impaired exercise tolerance. Our aim was to investigate changes in exercise capacity in children, adolescents and adults with Senning operation. Methods: Peak oxygen uptake (peak VO2), oxygen pulse and heart rate were assessed by cardiopulmonary exercise tests (CPET) and compared to normal values. Rates of change were calculated by linear regression analysis. Right ventricular (RV) function was assessed by echocardiography. Results: Thirty-four patients (22 male) performed 3.5 (range 3–6) CPET with an interval of ≥ 6 months. Mean age at first assessment was 16.4 ± 4.27 years. Follow-up period averaged 6.8 ± 2 years. Exercise capacity was reduced (p<0.0005) and the decline of peak VO2 (−1.3 ± 3.7 %/year; p=0.015) and peak oxygen pulse (−1.4 ± 3.0 %/year; p=0.011) was larger than normal, especially before adulthood and in female patients (p<0.01). During adulthood, RV contractility changes were significantly correlated with the decline of peak oxygen pulse (r= −0.504; p=0.047). Conclusions: In patients with Senning operation for d-TGA, peak VO2 and peak oxygen pulse decrease faster with age compared to healthy controls. This decline is most obvious during childhood and adolescence, and suggests the inability to increase stroke volume to the same extent as healthy peers during growth. Peak VO2 and peak oxygen pulse remain relatively stable during early adulthood. However, when RV contractility decreases, a faster decline in peak oxygen pulse is observed
DOCUMENT
Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. Material and Methods: The peak rate of oxygen consumption (ml×kg–1×min–1) was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA) were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET) in 95% of individuals. Results: None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs) were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg–1×min–1). Normative values for Dutch law enforcement officers were presented. Conclusions: Substantial differences between measured and predicted VO2peak (ml×kg–1×min–1) were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels.
DOCUMENT
No summary available
DOCUMENT
Objectives Patients who underwent corrective surgery for tetralogy of Fallot (TOF) have increased long-term risk of cardiovascular morbidity and mortality. Yet, limited information is available on how to evaluate the risk in this population. Therefore, the aim of this study was to investigate the prognostic value of aerobic exercise capacity, along with other related parameters, at medium-term follow-up in adult patients with tetralogy of Fallot. Methods and results Between 2000 and 2003, 92 adults (age 26.2 ± 7.8 years; 63 male) with corrected TOF or TOF-type morphology underwent a cardiopulmonary exercise test (CPET) until exhaustion and echocardiography. During a mean follow-up of 7.3 ± 1.2 years (range 0.9 to 9.3 years), 2 patients died and 26 patients required at least 1 cardiac-related intervention at a mean age of 28.9 ± 7.9 years. Event-free survival tended to be higher in patients with the classical type of TOF (P = 0.061). At multivariate Cox analysis, age at CPET [hazard ratio (HR): 1.13, P = 0.006], age at correction (HR: 0.82, P = 0.037), right ventricular (RV) function (HR: 4.94, P = 0.001), QRS duration (HR: 1.02, P = 0.007), percentage of predicted peak oxygen uptake (peak VO2%) (HR: 0.96, P = 0.029) and ventilatory effi ciency slope (VE/VCO2 slope) (HR: 1.13, P = 0.021) were signifi cantly related to the incidence of death/cardiac-related intervention during medium follow-up. Conclusions Early corrective surgery and a well-preserved RV are associated with a better outcome in adults with corrected TOF. Furthermore, CPET provides important prognostic information; peak VO2% and VE/VCO2 slope are independent predictors for event-free survival in patients with corrected TOF.
DOCUMENT
Introduction Physical activity is suggested to be important for low back pain (LBP) but a major problem is the limited validity of the measurement of physical activities, which is usually based on questionnaires. Physical fitness can be viewed as a more objective measurement and our question was how physical activity based on self-reports and objective measured levels of physical fitness were associated with LBP. Materials and methods We analyzed cross-sectional data of 1,723 police employees. Physical activity was assessed by questionnaire (SQUASH) measuring type of activity, intensity, and time spent on these activities. Physical fitness was based on muscular dynamic endurance capacity and peak oxygen uptake (VO2 peak). Severe LBP, interfering with functioning, was defined by pain ratings C4 on a scale of 0–10. Results Higher levels of physical fitness, both muscularand aerobic, were associated with less LBP (OR: 0.54; 95%CI: 0.34–0.86, respectively, 0.59: 95%CI: 0.35–0.99). For self-reported physical activity, both a low and a high level of the total physical activity pattern were associated with an increase of LBP (OR: 1.52; 95%CI: 1.00–2.31, respectively, 1.60; 95%CI: 1.05–2.44). Conclusion These findings suggest that physical activity of an intensity that improves physical fitness may be important in the prevention of LBP
DOCUMENT
Background Testing aerobic fitness in youth is important because of expected relationships with health. Objective The purpose of the study was to estimate the validity and reliability of the Shuttle Ride Test in youth who have spina bifida and use a wheelchair for mobility and sport. Design Ths study is a validity and reliability study. Methods The Shuttle Ride Test, Graded Wheelchair Propulsion Test, and skill-related fitness tests were administered to 33 participants for the validity study (age = 14.5 ± 3.1 y) and to 28 participants for the reliability study (age = 14.7 ± 3.3 y). Results No significant differences were found between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test for most cardiorespiratory responses. Correlations between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test were moderate to high (r = .55–.97). The variance in peak oxygen uptake (VO2peak) could be predicted for 77% of the participants by height, number of shuttles completed, and weight, with large prediction intervals. High correlations were found between number of shuttles completed and skill-related fitness tests (CI = .73 to −.92). Intraclass correlation coefficients were high (.77–.98), with a smallest detectable change of 1.5 for number of shuttles completed and with coefficients of variation of 6.2% and 6.4% for absolute VO2peak and relative VO2peak, respectively. Conclusions When measuring VO2peak directly by using a mobile gas analysis system, the Shuttle Ride Test is highly valid for testing VO2peak in youth who have spina bifida and use a wheelchair for mobility and sport. The outcome measure of number of shuttles represents aerobic fitness and is also highly correlated with both anaerobic performance and agility. It is not possible to predict VO2peak accurately by using the number of shuttles completed. Moreover, the Shuttle Ride Test is highly reliable in youth with spina bifida, with a good smallest detectable change for the number of shuttles completed.
DOCUMENT
This systematic review aims to get insight into the feasibility of cardiopulmonary exercise testing (CPET) in patients with cancer prior to a physical exercise programme. We will focus on quality (defined as the adherence to international guidelines for methods of CPET) and safety of CPET. Furthermore, we compare the peak oxygen uptake (V̇O2peak) values of patients with cancer with reference values for healthy persons to put these values into a clinical perspective. A computer aided search with ‘cardiopulmonary exercise testing’ and ‘cancer’ using MEDLINE, EMBASE, Pedro, CINAHL® and SPORTDiscus™ was carried out. We included studies in which CPET with continuous gas exchange analysis has been performed prior to a physical exercise programme in adults with cancer. Twenty studies describing 1158 patients were eligible. Reported adherence to international recommendations for CPET varied per item. In most studies, the methods of CPET were not reported in detail. Adverse events occurred in 1% of patients. The percentage V̇O2peak of reference values for healthy persons varied between 65% and 89% for tests before treatment, between 74% and 96% for tests during treatment and between 52% and 117% for tests after treatment. Our results suggest that CPET is feasible and seems to be safe for patients with cancer prior to a physical exercise programme. We recommend that standard reporting and quality guidelines should be followed for CPET methods. The decreased V̇O2peak values of patients with cancer indicate that physical exercise should be implemented in their standard care.
DOCUMENT
No summary available
DOCUMENT
Background The Six-Minute Walk Test (6MWT) is increasingly being used as a functional outcome measure for chronic pediatric conditions. Knowledge about its measurement properties is needed to determine whether it is an appropriate test to use. Purpose The purpose of this study was to systematically review all published clinimetric studies on the 6MWT in chronic pediatric conditions. Data Sources The databases MEDLINE, EMBASE, CINAHL, PEDro, and SPORTDiscus were searched up to February 2012. Study Selection Studies designed to evaluate measurement properties of the 6MWT in a chronic pediatric condition were included in the systematic review. Data Extraction The methodological quality of the included studies and the measurement properties of the 6MWT were examined. Data Synthesis A best evidence synthesis was performed on 15 studies, including 9 different chronic pediatric conditions. Limited evidence to strong evidence was found for reliability in various chronic conditions. Strong evidence was found for positive criterion validity of the 6MWT with peak oxygen uptake in some populations, but negative criterion validity was found in other populations. Construct validity remained unclear in most patient groups because of methodological flaws. Little evidence was available for responsiveness and measurement error. Studies showed large variability in test procedures despite existing guidelines for the performance of the 6MWT. Limitations Unavailability of a specific checklist to evaluate the methodological quality of clinimetric studies on performance measures was a limitation of the study. Conclusions Evidence for measurement properties of the 6MWT varies largely among chronic pediatric conditions. Further research is needed in all patient groups to explore the ability of the 6MWT to measure significant and clinically important changes. Until then, changes measured with the 6MWT should be interpreted with caution. Future studies or consensus regarding modified test procedures in the pediatric population is recommended.
DOCUMENT