This study evaluates the maximum theoretical exposure to radiofrequency (RF) electromag- netic fields (EMFs) from a Fifth-generation (5G) New Radio (NR) base station (BS) while using four commonly used mobile applications: YouTube for video streaming, WhatsApp for voice calls, Instagram for posting pictures and videos, and running a Video game. Three factors that might affect exposure, i.e., distance of the measurement positions from the BS, measurement time, and induced traffic, were examined. Exposure was assessed through both instantaneous and time-averaged extrapolated field strengths using the Maximum Power Extrapolation (MPE) method. The former was calculated for every measured SS-RSRP (Secondary Synchronization Reference Signal Received Power) power sample obtained with a sampling resolution of 1 second, whereas the latter was obtained using a 1-min moving average applied on the applications’ instantaneous extrapolated field strengths datasets. Regarding distance, two measurement positions (MPs) were selected: MP1 at 56 meters and MP2 at 170 meters. Next, considering the measurement time, all mobile application tests were initially set to run for 30 minutes at both MPs, whereas the video streaming test (YouTube) was run for an additional 150 minutes to investigate the temporal evolution of field strengths. Considering the traffic, throughput data vs. both instantaneous and time-averaged extrapolated field strengths were observed for all four mobile applications. In addition, at MP1, a 30-minute test without a User Equipment (UE) device was conducted to analyze exposure levels in the absence of induced traffic. The findings indicated that the estimated field strengths for mobile applications varied. It was observed that distance and time had a more significant impact than the volume of data traffic generated (throughput). Notably, the exposure levels in all tests were considerably lower than the public exposure thresholds set by the ICNIRP guidelines.INDEX TERMS 5G NR, C-band, human exposure assessment, mobile applications, traffic data, maximum extrapolation method, RF-EMF.
MULTIFILE
This work is on 3-D localization of sensor motes in massive swarms based solely on 1-D relative distance-measurements between neighbouring motes. We target applications in remote and difficult-to-access environments such as the exploration and mapping of the interior of oil reservoirs where hundreds or thousands of motes are used. These applications bring forward the need to use highly miniaturized sensor motes of less than 1 centimeter, thereby significantly limiting measurement and processing capabilities. These constraints, in combination with additional limitations posed by the environments, impede the communication of unique hardware identifiers, as well as communication with external, fixed beacons.
DOCUMENT
World globalisation drives companies to undertake international expansion with the aim of retaining or growing their businesses. When companies globalize, managers encounter new challenges in making international marketing strategy (IMS) decisions, which are influenced by perceived cultural and business distance between their home- and foreign country. Telkom Indonesia International (Telin) was formed by Telkom Indonesia (i.e. the state-owned company in the telecommunication industry in Indonesia) to engage in international business within a global market. The central question in this study is to what extent do managers’ perceived cultural and business distance between home- and foreign country influence their IMS decisions? A mixed research strategy will be employed by applying qualitative and quantitative methods concurrently. The data collection will involve interviews with CEOs and managers, alongside a web survey to 55 managers of Telkom's. Results suggest important consequences for IMS decisions and emphasizes the need for dialogue on perceptions of cultural and business characteristics of countries.
DOCUMENT
Local Gabor features (jets) have been widely used in face recognition systems. Once the sets of jets have been extracted from the two faces to be compared, a proper measure of similarity (or distance) between corresponding features should be chosen. For instance, in the well known Elastic Bunch Graph Matching (EBGM) approach and other Gabor-based face recognition systems, the cosine distance was used as a measure. In this paper, we provide an empirical evaluation of seven distance measures for comparison, using a recently introduced face recognition system, based on Shape Driven Gabor Jets (SDGJ). Moreover we evaluate different normalization factors that are used to pre-process the jets. Experimental results on the BANCA database suggest that the concrete type of normalization applied to jets is a critical factor, and that some combinations of normalization + distance achieve better performance than the classical cosine measure for jet comparison.
DOCUMENT
BACKGROUND: Exercise capacity, muscle function, and physical activity levels remain reduced in recipients of lung transplantation. Factors associated with this deficiency in functional exercise capacity have not been studied longitudinally.OBJECTIVE: The study aims were to analyze the longitudinal change in 6-minute walking distance and to identify factors contributing to this change.DESIGN: This was a longitudinal historical cohort study.METHODS: Data from patients who received a lung transplantation between March 2003 and March 2013 were analyzed for the change in 6-minute walking distance and contributing factors at screening, discharge, and 6 and 12 months after transplantation. Linear mixed-model and logistic regression analyses were performed with data on characteristics of patients, diagnosis, waiting list time, length of hospital stay, rejection, lung function, and peripheral muscle strength.RESULTS: Data from 108 recipients were included. Factors predicting 6-minute walking distance were measurement moment, diagnosis, sex, quadriceps muscle and grip strength, forced expiratory volume in 1 second (percentage of predicted), and length of hospital stay. After transplantation, 6-minute walking distance increased considerably. This initial increase was not continued between 6 and 12 months. At 12 months after lung transplantation, 58.3% of recipients did not reach the cutoff point of 82% of the predicted 6-minute walking distance. Logistic regression demonstrated that discharge values for forced expiratory volume in 1 second and quadriceps or grip strength were predictive for reaching this criterion.LIMITATIONS: Study limitations included lack of knowledge on the course of disease during the waiting list period, type and frequency of physical therapy after transplantation, and number of missing data points.CONCLUSIONS: Peripheral muscle strength predicted 6-minute walking distance; this finding suggests that quadriceps strength training should be included in physical training to increase functional exercise capacity. Attention should be paid to further increasing 6-minute walking distance between 6 and 12 months after transplantation.
LINK
AbstractIn many biomechanical motion studies, kinematic parameters are estimated from position measurements on a number of landmarks. In the present investigation, dummy motion experiments are performed in order to study the error dependence of kinematic parameters on geometric factors (number of markers, isotropic vs anisotropic landmark distributions, landmark distribution size), on kinematic factors (rotation step magnitude, the presence of translational displacements, the distance of the landmarks' mean position to the rotation axis), and on anisotropically distributed measurement errors. The experimental results are compared with theoretical predictions of a previous error analysis assuming isotropic conditions for the measurement errors and for the spatial landmark distribution. In general, the experimental findings agree with the predictions of the error model. The kinematic parameters such as translations and rotations are well-determined by the model. In the helical motion description, the same applies for the finite rotation angle about and the finite shift along the helical axis. However, the direction and position of the helical axis are ill-determined. An anisotropic landmark distribution with relatively few markers located in the direction of the rotation axis will even aggravate the ill-posed nature of the finite helical axis estimation.
DOCUMENT
Background To gain insight into the role of plantar intrinsic foot muscles in fall-related gait parameters in older adults, it is fundamental to assess foot muscles separately. Ultrasonography is considered a promising instrument to quantify the strength capacity of individual muscles by assessing their morphology. The main goal of this study was to investigate the intra-assessor reliability and measurement error for ultrasound measures for the morphology of selected foot muscles and the plantar fascia in older adults using a tablet-based device. The secondary aim was to compare the measurement error between older and younger adults and between two different ultrasound machines. Methods Ultrasound images of selected foot muscles and the plantar fascia were collected in younger and older adults by a single operator, intensively trained in scanning the foot muscles, on two occasions, 1–8 days apart, using a tablet-based and a mainframe system. The intra-assessor reliability and standard error of measurement for the cross-sectional area and/or thickness were assessed by analysis of variance. The error variance was statistically compared across age groups and machines. Results Eighteen physically active older adults (mean age 73.8 (SD: 4.9) years) and ten younger adults (mean age 21.9 (SD: 1.8) years) participated in the study. In older adults, the standard error of measurement ranged from 2.8 to 11.9%. The ICC ranged from 0.57 to 0.97, but was excellent in most cases. The error variance for six morphology measures was statistically smaller in younger adults, but was small in older adults as well. When different error variances were observed across machines, overall, the tablet-based device showed superior repeatability. Conclusions This intra-assessor reliability study showed that a tablet-based ultrasound machine can be reliably used to assess the morphology of selected foot muscles in older adults, with the exception of plantar fascia thickness. Although the measurement errors were sometimes smaller in younger adults, they seem adequate in older adults to detect group mean hypertrophy as a response to training. A tablet-based ultrasound device seems to be a reliable alternative to a mainframe system. This advocates its use when foot muscle morphology in older adults is of interest.
MULTIFILE
This study explored the dimensionality and measurement invariance of a multidimensional measure for evaluating teachers’ perceptions of the quality of their relationships with principals at the dyadic level. Participants were 630 teachers (85.9% female) from 220 primary and 204 secondary schools across the Netherlands. Teachers completed the 10-item Principal–Teacher Relationship Scale (PTRS) for their principals. Confirmatory factor analyses (CFA) provided evidence for a two-factor model, including a relational Closeness and Conflict dimension. Additionally, multigroup CFA results indicated strong invariance of the PTRS across school type, teacher gender, and teaching experience. Last, secondary school teachers and highly experienced teachers reported lower levels of Closeness and higher levels of Conflict in the relationship with their principal compared to primary school teachers and colleagues with less experience. Accordingly, the PTRS can be considered a valid and reliable measure that adds to the methodological repertoire of educational leadership research by focusing on both positive and negative aspects of dyadic principal–teacher relationships.
DOCUMENT
Modern engineering systems are complex socio-technical structures with a mission to offer services of high quality, while in parallel ensuring profitability for their owners. However, practice has shown that accidents are inevitable, and the need for the use of systems-theoretic tools to support safety-driven design and operation has been acknowledged. As indicated in accident investigation reports, the degradation of risk situation awareness (SA) usually leads to safety issues. However, the literature lacks a methodology to compare existing systems with their ideal composition, which is likely to enhance risk SA. To fill this gap, the risk SA provision (RiskSOAP) is a comparison-based methodology and goes through three stages: (1) determine the desired/ideal system composition, (2) identify the as-is one(s), (3) employ a comparative strategy to depict the distance between the compared units. RiskSOAP embodies three methods: STPA (System Theoretic Process Analysis), EWaSAP (Early Warning Sign Analysis) and dissimilarity measures. The practicality, applicability and generality of RiskSOAP is demonstrated through its application to three case studies. The purpose of this work is to suggest the RiskSOAP indicator as a measure for safety in terms of the gap between system design and operation, thus increasing system’s risk SA. RiskSOAP can serve as a criterion for planning system modifications or selecting between alternative systems, and can support the design, development, operation and maintenance of safe systems.
DOCUMENT
The estimation of the pose of a differential drive mobile robot from noisy odometer, compass and beacon distance measurements is studied. The estimation problem, which is a state estimation problem with unknown input, is reformulated into a state estimation problem with known input and a process noise term. A heuristic sensor fusion algorithm solving this state-estimation problem is proposed and compared with the extended Kalman filter solution and the Particle Filter solution in a simulation experiment. https://doi.org/10.4018/IJAIML.2020010101 https://www.linkedin.com/in/john-bolte-0856134/
DOCUMENT