ABSTRACT: Local homebuyers in the Groningen earthquake regionIr. Hieke T. van der KloetHanze University of Applied Sciences GroningenResearch Centre for Built Environment NoorderRuimteh.t.van.der.kloet@pl.hanze.nl0031-50-595-2015The earthquakes after the natural gas extraction in the Groningen region of the Netherlands have a significant impact on the housing market and sustainability of the communities in this region. Since the strongest earthquake around the community of Huizinge in August 2012, with an magnitude of 3.6 on the Richter scale, it became clear there is a relation between natural gas extraction and earthquakes due to soil subsidence. As a consequence houses in the region get damaged and after research it gets obvious housing prices decline and the region will become unattractive to potential buyers of houses, damaged or not. Therefore the Dutch Petroleum Company (NAM) since April 29th 2014 offers a compensation for the loss of the housing price before and after the earthquake of Huizinge to property owners who want to sell their home. They only get the compensation after a sales deal and only if they agree with the proposed compensation. Since the compensation for the decrease in house prices has been introduced, the number of participants of the regulation is lacking behind the actual sales of houses. Our study aims to contribute to the research on the consequences of earthquakes by natural gas mining on the real estate market in the northern part of the Netherlands, especially the Groningen region. First of all we want to declare why relatively a large part of the property owners (about 60% until 2015) don’t request for the compensation regulation. Our second question concerns the buyers of the (damaged) houses in the earthquake area. Why would they buy a home in a region full of risks? Who are these buyers? We use a mixed-method approach for data collection which leads to an analysis of a unique dataset on notarial deeds of house sales in nine municipalities in the Groningen earthquake region according to The Land Registry of the Netherlands during the period 2013 until the end of 2015 as well as discovering common patterns of interview results with residents and experts. First results show that the majority of the homebuyers originate from the local earthquake area in the Province of Groningen. Reasons why property sellers after the house sale don’t opt for the compensation regulation concerns the complexity of the regulation, the used valuation model and the expected long control time afterwards.From the first results we conclude that the Groningen earthquake region still has its attractiveness for local residents and buyers. Otherwise the regulation for compensation doesn’t reach enough property sellers in the nine municipalities of the Groningen earthquake region. Advise to the Dutch government should be to generously compensate the residents of the Groningen earthquake regions for the loss of value of their dwellings, damaged or not. This will help to improve the regional development and attractiveness of areas that are effected by earthquakes.
DOCUMENT
Few studies on residential mobility of ageing adults to rural areas have investigated which of them buy a home in a rural risk area. This paper examines which socio-demographic characteristics, housing attributes and earthquake circumstances influence the actual choice of mid-to-later life adults to purchase a house in a rural risk area. The study focuses on housing transactions in the Dutch Groningen rural earthquake region, compared to transactions in the Groningen rural non-earthquake area from 2012 to 2019 (N = 6,082). Buying a house in the Groningen risk area might be challenging, as the earthquakes have had a significant impact on the regional housing market, the building structure of the houses and the wellbeing of the residents. Earlier research nonetheless suggests that, despite the risks, homebuyers still purchase houses in the Groningen earthquake area. The developed model predicts which mid-to-later life homebuyers of 50 years and older will purchase a dwelling in the Groningen earthquake region. Logistic regression analyses show that characteristics of the mid-to-later life homebuyer and earthquake circumstances are decisive aspects in respect of this choice. Being a single mid-to-later life homebuyer, with a previous residence in the Groningen earthquake region or being born in this region, enlarges the probability of purchasing a home in the earthquake region. Another significant predictor of a home purchase in the earthquake region appears to be a higher earthquake intensity of the homebuyer’s previous residence. These conclusions indicate the existence of a local housing market in rural risk areas.
DOCUMENT
Few studies have investigated staying intentions and house attachment of residents who are confronted with physical damage to their dwelling in a risk area. This paper examines whether and how homeowners who are confronted with human-induced risks and the consequences of gas extraction in the Dutch Groningen rural earthquake region are attached to their damaged dwellings and why they stay. A content analysis was performed on 92 published interviews with homeowners of damaged dwellings. Additionally, three semi-structured interviews were held with key journalists and a homeowner. The results show that the homeowners’ staying intentions are interrelated with their house attachment; moreover, their awareness of their house attachment arises precisely because of the damage. We identify five subdimensions of physical and social house attachment, related to family history, heritage, (agricultural) business, personal refurbishment, and cohabiting family members, which make homeowners want to stay. The family history is especially mentioned by mid-to-later life homeowners, while some younger homeowners emphasize social house attachment to their children.We conclude that a homeowner's decision to stay in a damaged dwelling is a continuous cycle of reconsideration and renegotiation, punctuated by potential new risks and damages influencing the house attachment and staying intentions. Based on the found dimensions of house attachment, policymakers in risk areas could apply different approaches to homeowners in case of damage repair, rebuilding, or relocation plans, as homeowners - even those with damaged dwellings - may prefer to stay.
DOCUMENT
Groningen gas field is the largest on-land gas resource in the world and is beingexploited since 1963. There are damaging earthquakes, the largest of which was 3.6 magnitude. The recursive induced earthquakes are often blamed for triggering the structural damages in thousands of houses in the area. A damage claim procedure takes place after each significantly felt earthquake. The liability of the exploiting company is related to the damages and the engineering firms and experts are asked to correlate the claimed damages with a past earthquake. Structures in the region present high vulnerabilities to the lateral forces, soilproperties are quite unfavourable for seismic resistance, and structural damages are present even without earthquakes. This situation creates a dispute area where one can claim that most structures in the region were already damaged because of the fact that the soil is soft, the ground water table oscillates, and structures are vulnerable to external conditions anyhow and deteriorate in time, which can be the main cause of such structural damages. This ambiguity of damage vs earthquake correlation is one of the main sources of the public unrest in the area up until today. This study presents the perspective of people in the region in terms of liveability and the social acceptance of earthquakes in their lives. An attempt has been made to translate these social effects and expectations into structural performance metrics for ordinary houses in the region. A new seismic design and assessment approach, called Comfort Level Earthquake (CLE) has been proposed.
DOCUMENT
The earthquakes after the natural gas extraction in the Groningen region of the Netherlands have a significant impact on the housing market and sustainability of the communities. Since the strongest earthquake around the community of Huizinge in August 2012, with a magnitude of 3.6 on the Richter scale, it became clear there is a relation between natural gas extraction and earthquakes due to soil subsidence. As a consequence houses in the region get damaged and after research it is obvious that housing prices decline and the region might become unattractive to potential buyers of houses. Therefore the Dutch Petroleum Company (NAM) since April 29th 2014 offers a compensation for the loss of the housing price to property owners who want to sell their home. Since the compensation has been introduced, the number of participants of the regulation is lacking behind the actual sales of houses. Our study aims to contribute to the research on the consequences of earthquakes by natural gas mining on the real estate market in the Groningen region. First of all we want to declare why relatively a large part of the property owners (about 60% until 2015) don’t request for the compensation regulation. Our second question concerns the buyers of the (damaged) houses in the earthquake area. Who are these buyers? Why would they buy a home in a region full of risks? We use a mixed-method approach for data collection which leads to an analysis of a unique dataset on notarial deeds of house sales in nine municipalities in the Groningen earthquake region according to The Land Registry of the Netherlands during the period 2013 until 2015 as well as discovering common patterns of interview results with residents and experts.First results show the majority of the homebuyers originate from the local earthquake area in the Province of Groningen. Reasons why property sellers after the house sale don’t opt for the compensation regulation concerns the complexity of the regulation, the used valuation model and the expected long control time afterwards.We conclude the Groningen earthquake region still has it’s attractiveness for local residents and buyers. Otherwise the regulation for compensation doesn’t reach enough property sellers in the Groningen earthquake region. Advise to the Dutch government should be to generously compensate the residents of the Groningen earthquake regions for the loss of the value of their dwellings, damaged or not. This will help to improve the regional development and attractiveness of areas that are effected by earthquakes.
DOCUMENT
Post-earthquake structural damage shows that out-of-plane wall collapse is one of the most prevalent failure mechanisms in unreinforced masonry (URM) buildings. This issue is particularly critical in Groningen, a province located in the northern part of the Netherlands, where low-intensity ground shaking has occurred since 1991 due to gas extraction. The majority of buildings in this area are constructed using URM and were not designed to withstand earthquakes, as the area had never been affected by tectonic seismic activity before. Hence, the assessment of URM buildings in the Groningen province has become of high relevance.Out-of-plane failure mechanisms in brick masonry structures often stem from poor wall-to-wall, wall-to-floor or wall-to-roof connections that provide insufficient restraint and boundary conditions. Therefore, studying the mechanical behaviour of such connections is of prime importance for understanding and preventing damages and collapses in URM structures. Specifically, buildings with double-leaf cavity walls constitute a large portion of the building stock in the Groningen area. The connections of the leaves in cavity walls, which consist of metallic ties, are expected to play an important role. Regarding the wall-to-floor connections, the traditional way for URM structures in Dutch construction practice is either a simple masonry pocket connection or a hook anchor as-built connection, which are expected to be vulnerable to out-of-plane excitation. However, until now, little research has been carried out to characterise the seismic behaviour of connections between structural elements in traditional Dutch construction practice.This thesis investigates the seismic behaviour of two types of connections: wall-to-wall connections between cavity wall leaves and wall-to-floor connections between the masonry cavity wall and timber diaphragm, commonly found in traditional houses in the Groningen area. The research is divided into three phases: (1) inventory of existing buildings and connections in the Groningen area, (2) performance of experimental tests, and (3) proposal and validation of numerical and mechanical models. The thesis explores the three phases as follows:(i) An inventory of connections within URM buildings in the Groningen area is established. The inventory includes URM buildings of Groningen based on construction material, lateral load-resisting system, floor system, number of storeys, and connection details. Specific focus is given to the wall-to-wall and wall-to-floor connections in each URM building. The thickness of cavity wall leaves, the air gap between the leaves and the size and spacing of timber joists are key aspects of the inventory.(ii) Experimental tests are performed on the most common connection typologies identified in the inventory. This phase consists of two distinct experimental campaigns:o The first experimental campaign took place at the laboratory of the Delft University of Technology to provide a comprehensive characterisation of the axial behaviour of traditional metal tie connections in cavity walls. The campaign included a wide range of variations, such as two embedment lengths, four pre-compression levels, two different tie geometries, and five different testing protocols, including both monotonic and cyclic loading. The experimental results showed that the capacity of the wall tie connection is strongly influenced by the embedment length and the tie geometry, whereas the applied pre-compression and the loading rate do not have a significant influence.o The second experimental campaign has been carried out at the laboratory of the Hanze University of Applied Sciences to characterise the seismic behaviour of timber joist-masonry cavity wall connections, reproducing both as-built and strengthened conditions. Twenty-two unreinforced masonry wallets were tested, with different configurations, including two tie distributions, two pre-compression levels, two different as-built connections, and two different strengthening solutions. The experimental results highlighted the importance of cohesion and friction between joist and masonry since the type of failure mechanism (sliding of the joist or rocking failure of the masonry wallet) depends on the value of these two parameters. Additionally, the interaction between the joist and the wallet and the uplift of the latter activated due to rocking led to an arching effect that increased friction at the interface between the joist and the masonry. Consequently, the arching effect enhanced the force capacity of the connection.(iii) Mechanical and numerical models are proposed and validated against the performed experiments or other benchmarks. Mechanical and numerical models for the cavity wall tie and mechanical models for the timber joist-masonry connections were developed and verified by the experimental results to predict the failure mode and the strength capacity of the examined connections in URM buildings.o The mechanical model for the cavity wall tie connections considers six possible failures, namely tie failure, cone break-out failure, pull-out failure, buckling failure, piercing failure and punching failure. The mechanical model is able to capture the mean peak force and the failure mode obtained from the tests. After being calibrated against the available experiments, the proposed mechanical model is used to predict the performance of untested configurations by means of parametric analyses, including higher strength of mortar for calcium silicate brick masonry, different cavity depth, different tie embedment depth, and the use of solid bricks in place of perforated clay bricks.o The results of the experimental campaign on cavity wall ties were also utilised to calibrate a hysteretic numerical model representing the cyclic axial response of cavity wall tie connections. The proposed model uses zero-length elements implemented in OpenSees with the Pinching4 constitutive model to account for the compression-tension cyclic behaviour of the ties. The numerical model is able to capture important aspects of the tie response, such as strength degradation, unloading stiffness degradation, and pinching behaviour. The mechanical and numerical modelling approach can be easily adopted by practitioner engineers seeking to model the wall ties more accurately when assessing URM structures against earthquakes.o The mechanical model of timber-masonry connections examines two different failure modes: joist-sliding failure mode, including joist-to-wall interaction and rocking failure mode due to joist movement. Both mechanical models have been validated against the outcomes of the experimental campaigns conducted on the corresponding connections. The mechanical model is able to estimate each contribution of the studied mechanism. Structural engineers can use the mechanical model to predict the capacity of the connection for the studied failure modes.This research study can contribute to a better understanding of typical Groningen houses in terms of identifying the most common connections used at wall-to-wall and wall-to-floor connections in cavity walls, characterising the identified connections and proposing mechanical models for the studied connections.
DOCUMENT
''Heritage buildings are often subjected to loading conditions that they were not exposed to in their earlier life span. Induced earthquakes in non-seismic regions caused by energy exploitation activities, or strains in the ground that are caused by the climate changes, are new phenomena that alter the usual loading situations for historical buildings.In this paper, monitoring results of a historical building in Groningen (Netherlands) in case of induced seismicity as well as climate change effects has been presented. Long-term monitoring results, detected cracks and relevance of the monitoring data are discussed. In the special case of Groningen, weak and agricultural soil properties dominate the structural response in the region. The gas extraction activities caused a soil subsidence in the giant Groningen Gas Field, resulting decameters of settlement in the entire area, thus an increase of the ground water level in respect to the ground surface. This is the reason why the heritage structures in the region are more vulnerable to soil-water-foundation interactions caused by climate change as compared to the time these heritage structures were constructed. The ground water monitoring as well as the interaction of soil movements with the structural response become important. The study presented here suggests ways on how to effectively monitor historical structures subjected to induced seismicity as well as harsh climate effects at the same time.It was shown here that the newly developed cracks on the structure were detected in a very narrow time window, coinciding with extreme drought and a small induced earthquake at the same time. One explanation provided here is that the soil parameters, such as shrinking of water-sensitive soil layers, in combination with small earthquakes, may cause settlements. The soil effects may superimpose with the earthquake effects eventually causing small cracks and damage. The effects of the climate change on historical buildings is rather serious, and structures on similar soil conditions around the world would need detailed monitoring of not only the structure itself but also the soil-foundation and ground water conditions.''
DOCUMENT
Fraeylemaborg is a noble house in an earthquake-stricken area of the Netherlands due to the induced seismicity events in the region. The structure is located in the middle of the town of Slochteren which gave its name to the largest gas field in the world upon its discovery in 1959. The gas extraction has caused small-magnitude shallow earthquakes during the last decade, damaging not only the residential inventory but also the historical structures in the area. The main building of Fraeylemaborg sits on an artificial island surrounded by water channels, rendering the problem of earthquake response even more complicated. A small part of the main structure on the island was built in the 14th century, while the construction of additional parts and morphological alterations had taken place until the 18th century. The structure has been subjected to several small magnitude earthquakes causing damages on the load bearing system. An extensive renovation and repair of damages took place in recent years, however the latest seismic events imposed again damage to the structure. This paper presents a project of monitoring, assessment and diagnosis of problems for the Fraeylemaborg, the most important “borg” of the region, underlining the particularities of the induced seismicity problem. The FE model has been calibrated by using ambient vibration tests. Combination of earthquake and soil settlement loads have been applied on the calibrated model. The paper develops scenarios that help in explaining the reasons behind the damages on this structure during the recent shallow and low-magnitude induced seismicity earthquakes.