Objective. After laryngectomy, the breathing resistance of heat and moisture exchangers may limit exercise capacity. Breathing gas analysis during cardiopulmonary exercise testing is not possible using regular masks. This study tested the feasibility of cardiopulmonary exercise testing with a heat and moisture exchanger in situ, using an in-house designed connector. Additionally, we explored the effect of different heat and moisture exchanger resistances on exercise capacity in this group. Methods. Ten participants underwent two cardiopulmonary exercise tests using their daily life heat and moisture exchanger (0.3 hPa or 0.6 hPa) and one specifically developed for activity (0.15 hPa). Heat and moisture exchanger order was randomised and blinded.Results. All participants completed both tests. No (serious) adverse events occurred. Only four subjects reached a respiratory exchange ratio of more than 1.1 in at least one test. Maximum exercise levels using heat and moisture exchangers with different resistances did not differ. Conclusion. Cardiopulmonary exercise testing in laryngectomees with a heat and moisture exchanger is feasible; however, the protocol does not seem appropriate to reach this group's maximal exercise capacity. Lowering heat and moisture exchanger resistance does not increase exercise capacity in this sample.
DOCUMENT
Objective: To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. Data sources: PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. Study selection: VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/ or responsiveness of cardiopulmonary exercise test protocols. Data extraction: Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Data synthesis: Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. Conclusion: No judgement could be made on which protocol is “best” for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.
DOCUMENT
OBJECTIVE: To further test the validity and clinical usefulness of the steep ramp test (SRT) in estimating exercise tolerance in cancer survivors by external validation and extension of previously published prediction models for peak oxygen consumption (Vo2peak) and peak power output (Wpeak).DESIGN: Cross-sectional study.SETTING: Multicenter.PARTICIPANTS: Cancer survivors (N=283) in 2 randomized controlled exercise trials.INTERVENTIONS: Not applicable.MAIN OUTCOME MEASURES: Prediction model accuracy was assessed by intraclass correlation coefficients (ICCs) and limits of agreement (LOA). Multiple linear regression was used for model extension. Clinical performance was judged by the percentage of accurate endurance exercise prescriptions.RESULTS: ICCs of SRT-predicted Vo2peak and Wpeak with these values as obtained by the cardiopulmonary exercise test were .61 and .73, respectively, using the previously published prediction models. 95% LOA were ±705mL/min with a bias of 190mL/min for Vo2peak and ±59W with a bias of 5W for Wpeak. Modest improvements were obtained by adding body weight and sex to the regression equation for the prediction of Vo2peak (ICC, .73; 95% LOA, ±608mL/min) and by adding age, height, and sex for the prediction of Wpeak (ICC, .81; 95% LOA, ±48W). Accuracy of endurance exercise prescription improved from 57% accurate prescriptions to 68% accurate prescriptions with the new prediction model for Wpeak.CONCLUSIONS: Predictions of Vo2peak and Wpeak based on the SRT are adequate at the group level, but insufficiently accurate in individual patients. The multivariable prediction model for Wpeak can be used cautiously (eg, supplemented with a Borg score) to aid endurance exercise prescription.
DOCUMENT