Data collected from fitness trackers worn by employees could be very useful for businesses. The sharing of this data with employers is already a well-established practice in the United States, and companies in Europe are showing an interest in the introduction of such devices among their workforces. Our argument is that employers processing their employees’ fitness trackers data is unlikely to be lawful under the General Data Protection Regulation (GDPR). Wearable fitness trackers, such as Fitbit and AppleWatch devices, collate intimate data about the wearer’s location, sleep and heart rate. As a result, we consider that they not only represent a novel threat to the privacy and autonomy of the wearer, but that the data gathered constitutes ‘health data’ regulated by Article 9. Processing health data, including, in our view, fitness tracking data, is prohibited unless one of the specified conditions in the GDPR applies. After examining a number of legitimate bases which employers can rely on, we conclude that the data processing practices considered do not comply with the principle of lawfulness that is central to the GDPR regime. We suggest alternative schema by which wearable fitness trackers could be integrated into an organization to support healthy habits amongst employees, but in a manner that respects the data privacy of the individual wearer.
MULTIFILE
Background: Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions.Method: Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC).Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots.Results: Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (−0.2, −0.4), Fibit Flex (−5.7, 3.7), Jawbone Up (−1.0, 1.4), Nike+ Fuelband (−18, −24), Misfit Shine (0.2, 1.1), Withings Pulse (−0.5, −7.9), Fitbit Zip (−0.3, 1.2), Omron (2.5, −0.4), Digiwalker (−1.2, −5.9), and Moves app (9.6, −37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition.Conclusion: The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low.
DOCUMENT
Aim: The aim of this study was to describe the experience with commercially available activity trackers embedded in the physiotherapy treatment of patients with a chronic disease. Methods: In a qualitative study, 29 participants with a chronic disease participated. They wore an activity tracker for two to eight weeks. Data were collected using 23 interviews and discussion with 6 participants. A framework analysis was used to analyze the data. Results: The framework analysis resulted in seven categories: purchase, instruction, characteristics, correct functioning, sharing data, privacy, use, and interest in feedback. The standard goal of the activity trackers was experienced as too high, however the tracker still motivated them to be more active. Participants would have liked more guidance from their physiotherapists because they experienced the trackers as complex. Participants experienced some technical failures, are willing to share data with their physiotherapist and, want to spend a maximum of €50,-. Conclusion: The developed framework gives insight into all important concepts from the experiences reported by patients with a chronic disease and can be used to guide further research and practice. Patients with a chronic disease were positive regarding activity trackers in general. When embedded in physiotherapy, more attention should be paid to the integration in treatment.
DOCUMENT
Aim: The aim of this study was to describe the experience with commercially available activity trackers embedded in the physiotherapy treatment of patients with a chronic disease. Methods: In a qualitative study, 29 participants with a chronic disease participated. They wore an activity tracker for two to eight weeks. Data were collected using 23 interviews and discussion with 6 participants. A framework analysis was used to analyze the data. Results: The framework analysis resulted in seven categories: purchase, instruction, characteristics, correct functioning, sharing data, privacy, use, and interest in feedback. The standard goal of the activity trackers was experienced as too high, however the tracker still motivated them to be more active. Participants would have liked more guidance from their physiotherapists because they experienced the trackers as complex. Participants experienced some technical failures, are willing to share data with their physiotherapist and, want to spend a maximum of e50,-. Conclusion: The developed framework gives insight into all important concepts from the experiences reported by patients with a chronic disease and can be used to guide further research and practice. Patients with a chronic disease were positive regarding activity trackers in general. When embedded in physiotherapy, more attention should be paid to the integration in treatment.
DOCUMENT
Despite the increased use of activity trackers, little is known about how they can be used in healthcare settings. This study aimed to support healthcare professionals and patients with embedding an activity tracker in the daily clinical practice of a specialized mental healthcare center and gaining knowledge about the implementation process. An action research design was used to let healthcare professionals and patients learn about how and when they can use an activity tracker. Data collection was performed in the specialized center with audio recordings of conversations during therapy, reflection sessions with the therapists, and semi-structured interviews with the patients. Analyses were performed by directed content analyses. Twenty-eight conversations during therapy, four reflection sessions, and eleven interviews were recorded. Both healthcare professionals and patients were positive about the use of activity trackers and experienced it as an added value. Therapists formulated exclusion criteria for patients, a flowchart on when to use the activity tracker, defined goals, and guidance on how to discuss (the data of) the activity tracker. The action research approach was helpful to allow therapists to learn and reflect with each other and embed the activity trackers into their clinical practice at a specialized mental healthcare center.
DOCUMENT
In dit review wordt een overzicht gegeven van effect van mobiele applicaties en activity trackers op een gezonde leefstijl. 17 artikelen werden geïncludeerd. De effecten van apps op beweeggedrag lijken positief. Het effect van apps op voeding en gewicht was wisselend. Maar er leek een trend te zijn voor verbetering van het voedingspatroon. Er is nog weinig onderzoek gedaan naar effect van activity trackers op leefstijl, maar eerste resultaten laten een positieve invloed zien op beweeggedrag. Voor apps aanbevolen kunnen worden, is verder onderzoek nodig. Hiervoor is grootschalig onderzoek nodig met uitgebalanceerde controlegroepen en lange termijn follow-up testen.
DOCUMENT
This study offers an overview of the natural development of the use of an activity tracker, as well as the relative importance of a range of determinants from literature. Decay is exponential but slower than may be expected from existing literature. Many factors have a small contribution to sustained use. The most important determinants are technical condition, age, user experience, and goal-related factors. This finding suggests that activity tracking is potentially beneficial for a broad range of target groups, but more attention should be paid to technical and user experience–related aspects of activity trackers.
MULTIFILE
This paper reports on the first stage of a research project1) that aims to incorporate objective measures of physical activity into health and lifestyle surveys. Physical activity is typically measured with questionnaires that are known to have measurement issues, and specifically, overestimate the amount of physical activity of the population. In a lab setting, 40 participants wore four different sensors on five different body parts, while performing various activities (sitting, standing, stepping with two intensities, bicycling with two intensities, walking stairs and jumping). During the first four activities, energy expenditure was measured by monitoring heart rate and the gas volume of in‐ and expired O2 and CO2. Participants subsequently wore two sensor systems (the ActivPAL on the thigh and the UKK on the waist) for a week. They also kept a diary keeping track of their physical activities, work and travel hours. Machine learning algorithms were trained with different methods to determine which sensor and which method was best able to differentiate the various activities and the intensity with which they were performed. It was found that the ActivPAL had the highest overall accuracy, possibly because the data generated on the upper tigh seems to be best distinguishing between different types of activities and therefore led to the highest accuracy. Accuracy could be slightly increased by including measures of heartrate. For recognizing intensity, three different measures were compared: allocation of MET values to activities (used by ActivPAL), median absolute deviation, and heart rate. It turns out that each method has merits and disadvantages, but median absolute deviation seems to be the most promishing metric. The search for the best method of gauging intensity is still ongoing. Subsequently, the algorithms developed for the lab data were used to determine physical activity in the week people wore the devices during their everyday activities. It quickly turned out that the models are far from ready to be used on free living data. Two approaches are suggested to remedy this: additional research with meticulously labelled free living data, e.g., by combining a Time Use Survey with accelerometer measurements. The second is to focus on better determining intensity of movement, e.g., with the help of unsupervised pattern recognition techniques. Accuracy was but one of the requirements for choosing a sensor system for subsequent research and ultimate implementation of sensor measurement in health surveys. Sensor position on the body, wearability, costs, usability, flexibility of analysis, response, and adherence to protocol equally determine the choice for a sensor. Also from these additional points of view, the activPAL is our sensor of choice.
DOCUMENT
Due to a lack of transparency in both algorithm and validation methodology, it is diffcult for researchers and clinicians to select the appropriate tracker for their application. The aim of this work is to transparently present an adjustable physical activity classification algorithm that discriminates between dynamic, standing, and sedentary behavior. By means of easily adjustable parameters, the algorithm performance can be optimized for applications using different target populations and locations for tracker wear. Concerning an elderly target population with a tracker worn on the upper leg, the algorithm is optimized and validated under simulated free-living conditions. The fixed activity protocol (FAP) is performed by 20 participants; the simulated free-living protocol (SFP) involves another 20. Data segmentation window size and amount of physical activity threshold are optimized. The sensor orientation threshold does not vary. The validation of the algorithm is performed on 10 participants who perform the FAP and on 10 participants who perform the SFP. Percentage error (PE) and absolute percentage error (APE) are used to assess the algorithm performance. Standing and sedentary behavior are classified within acceptable limits (+/- 10% error) both under fixed and simulated free-living conditions. Dynamic behavior is within acceptable limits under fixed conditions but has some limitations under simulated free-living conditions. We propose that this approach should be adopted by developers of activity trackers to facilitate the activity tracker selection process for researchers and clinicians. Furthermore, we are convinced that the adjustable algorithm potentially could contribute to the fast realization of new applications.
DOCUMENT
In deze workshop komen het bevorderen van sportparticipatie en de rol van applicaties en wearables hierin naar voren. Met aandacht voor: apps voor hardlopers, apps voor inactieven, apps voor professionals en patiënten, ideeën voor de toekomst
DOCUMENT