The rain gardens at Bryggen in Bergen, Western Norway, is designed to collect, retain, and infiltrate surface rainfall runoff water, recharge the groundwater, and replenish soil moisture. The hydraulic infiltration capacity of the Sustainable Drainage System (SuDS), here rain gardens, has been tested with small-scale and full-scale infiltration tests. Results show that infiltration capacity meets the requirement and is more than sufficient for infiltration in a cold climate. The results from small-scale test, 245–404 mm/h, shows lower infiltration rates than the full-scale infiltration test, with 510–1600 mm/h. As predicted, an immediate response of the full-scale infiltration test is shown on the groundwater monitoring in the wells located closest to the infiltration point (<30 m), with a ca. 2 days delayed response in the wells further away (75–100 m). Results show that there is sufficient capacity for a larger drainage area to be connected to the infiltration systems. This study contributes to the understanding of the dynamics of infiltration systems such as how a rain garden interacts with local, urban water cycle, both in the hydrological and hydrogeological aspects. The results from this study show that infiltration systems help to protect and preserve the organic rich cultural layers below, as well as help with testing and evaluating of the efficiency, i.e., SuDS may have multiple functions, not only storm water retention. The functionality is tested with water volumes of 40 m3 (600 L/min for 2 h and 10 min), comparable to a flash flood, which give an evaluation of the infiltration capacity of the system.
DOCUMENT
Permeable pavements are specifically designed to promote the infiltration of stormwater through the paving surface in order to reduce run-off volumes and to improve water quality by removing sediment and other pollutants. However, research has shown that permeable pavements can become clogged over time and this reduces their infiltration capacity. In order to assess the infiltration of permeable pavements, a variety of infiltration test procedures have been utilised in the past. However, the results have generally been inconsistent, and have shown a large variation in the range of infiltration rates measured. This paper evaluates the performance of two new experimental test methods developed in the Netherlands to more accurately determine the surface infiltration rate of existing permeable pavement installations. The two methods were the falling head full-scale method and the constant head full-scale method. Both of the new methods involved inundating a large area of the pavement in order to determine the infiltration rate through the pavement surface. Double ring infiltrometer tests were also performed to enable a comparison of the results. The study found that the new falling head full-scale testing method produced the most accurate results.
DOCUMENT
This research used a newly developed, full-scale infiltration testing (FSIT) procedure to determine the saturated surface infiltration rate of 16 existing permeable pavement installations in the Netherlands that have been in service for a number of years. Newly installed permeable pavements in the Netherlands must demonstrate a minimum infiltration capacity of 194 mm/h (540 L/s/ha). Only four of the 16 pavements tested in this study had an infiltration capacity higher than 194 mm/h. Most previous research has focused on unsaturated infiltration rates. However, the results of this study show that the difference in infiltration capacity between saturated and unsaturated can differ by up to 300%. If the unsaturated infiltration capacity is used as design input for computer models, the infiltration capacity may be significantly overestimated. The study demonstrated that the FSIT method is a reliable and accurate way to measure surface infiltration rates of permeable pavements. However, it is recommended that a minimum of three different FSIT tests should be undertaken at the same pavement location, and that the results should be averaged, to ensure appropriate infiltration rates are observed, recorded, and used in design. The results of this study should help stormwater managers with the planning, testing, and scheduling of maintenance requirements for permeable pavements with more confidence so that they will continue to perform satisfactorily over their intended design life
DOCUMENT