Poster KIM voor de ECR is nu online te zien via EPOS: https://epos.myesr.org/poster/esr/ecr2022/C-16092 posternummer: C-16092, ECR 2022 Purpose Artificial Intelligence (AI) has developed at high speed the last few years and will substantially change various disciplines (1,2). These changes are also noticeable in the field of radiology, nuclear medicine and radiotherapy. However, the focus of attention has mainly been on the radiologist profession, whereas the role of the radiographer has been largely ignored (3). As long as AI for radiology was focused on image recognition and diagnosis, the little attention for the radiographer might be justifiable. But with AI becoming more and more a part of the workflow management, treatment planning and image reconstruction for example, the work of the radiographer will change. However, their training (courses Medical Imaging and Radiotherapeutic Techniques) hardly contain any AI education. Radiographers in the Netherlands are therefore not prepared for changes that will come with the introduction of AI into everyday work.
LINK
DOCUMENT
Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems.METHODS: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC).RESULTS: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density.CONCLUSION: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.
DOCUMENT
Abstract: AI tools in radiology are revolutionising the diagnosis, evaluation, and management of patients. However, there is a major gap between the large number of developed AI tools and those translated into daily clinical practice, which can be primarily attributed to limited usefulness and trust in current AI tools. Instead of technically driven development, little effort has been put into value-based development to ensure AI tools will have a clinically relevant impact on patient care. An iterative comprehensive value evaluation process covering the complete AI tool lifecycle should be part of radiology AI development. For value assessment of health technologies, health technology assessment (HTA) is an extensively used and comprehensive method. While most aspects of value covered by HTA apply to radiology AI, additional aspects, including transparency, explainability, and robustness, are unique to radiology AI and crucial in its value assessment. Additionally, value assessment should already be included early in the design stage to determine the potential impact and subsequent requirements of the AI tool. Such early assessment should be systematic, transparent, and practical to ensure all stakeholders and value aspects are considered. Hence, early value-based development by incorporating early HTA will lead to more valuable AI tools and thus facilitate translation to clinical practice. Clinical relevance statement: This paper advocates for the use of early value-based assessments. These assessments promote a comprehensive evaluation on how an AI tool in development can provide value in clinical practice and thus help improve the quality of these tools and the clinical process they support. Key Points: Value in radiology AI should be perceived as a comprehensive term including health technology assessment domains and AI-specific domains. Incorporation of an early health technology assessment for radiology AI during development will lead to more valuable radiology AI tools. Comprehensive and transparent value assessment of radiology AI tools is essential for their widespread adoption.
DOCUMENT
The main objective of this study was to make the transition from afilm (2D) based pre-treatment IMRT / IMAT QA into a moreefficient and clinical relevant method of verification byreconstructing the dose directly in the patient CT using theCOMPASS system. The evaluation of the reconstructeddose includes DVHs and a gamma index evaluation.
DOCUMENT
Our study shows a steady increase in dementia- and DHT-related publications, particularly in areas such as mobile health, virtual reality, artificial intelligence, and sensor-based technologies interventions. This increase underscores the importance of systematic approaches and interdisciplinary collaborations, while identifying knowledge gaps, especially in lower-income regions. It is crucial that researchers worldwide adhere to evidence-based medicine principles to avoid duplication of efforts. This analysis offers a valuable foundation for policy makers and academics, emphasizing the need for an international collaborative task force to address knowledge gaps and advance dementia care globally.
MULTIFILE
Abstract gepubliceerd in Elsevier: Introduction: Recent research has identified the issue of ‘dose creep’ in diagnostic radiography and claims it is due to the introduction of CR and DR technology. More recently radiographers have reported that they do not regularly manipulate exposure factors for different sized patients and rely on pre-set exposures. The aim of the study was to identify any variation in knowledge and radiographic practice across Europe when imaging the chest, abdomen and pelvis using digital imaging. Methods: A random selection of 50% of educational institutes (n ¼ 17) which were affiliated members of the European Federation of Radiographer Societies (EFRS) were contacted via their contact details supplied on the EFRS website. Each of these institutes identified appropriate radiographic staff in their clinical network to complete an online survey via SurveyMonkey. Data was collected on exposures used for 3 common x-ray examinations using CR/DR, range of equipment in use, staff educational training and awareness of DRL. Descriptive statistics were performed with the aid of Excel and SPSS version 21. Results: A response rate of 70% was achieved from the affiliated educational members of EFRS and a rate of 55% from the individual hospitals in 12 countries across Europe. Variation was identified in practice when imaging the chest, abdomen and pelvis using both CR and DR digital systems. There is wide variation in radiographer training/education across countries.
DOCUMENT
Rationale: Although ultrasound has been reported as valid and reliable tool to assess muscle size in older adults1, little is known about intra-rater reliability (intra-RR) and inter-rater reliability (inter-RR) of BodyMetrix in specific to assess small muscles. Therefore, in this study we aimed to assess intra-RR and inter-RR of biceps muscle size (thickness) in elderly.Methods: Thirty elderly (81.9±6.3 years; 80% women; BMI 26.7±5.3 kg/m2) living in a Portuguese nursing home/residence were included. To assess procedural intra-RR and inter-RR, ultrasound measurements were performed by two raters (R1, R2, beginners level) by BodyMetrixTM BX2000, on the biceps of the right arm. R1 repeated the ultrasound measurement once. To assess measurement intra-RR and inter-RR, images were analyzed by three raters (R1, R2, and R3 [experienced level]). Agreement was analyzed by intraclass correlation coefficient. ICC values of 0.50 to 0.75 were considered moderate to good, and >0.75 as good to excellent. Statistical significance was set at p<0.05.Results: Mean muscle thickness at 1st and 2nd measurement (R1) was 23.4±4.5 and 23.7±3.8 mm, respectively. For procedural intra-RR, ICC was 0.630. For inter-RR of image 1 (R1) vs. image 2 (R2), ICC was 0.622. For inter-RR of image 2 (R2) vs. image 3 (R1) ICC was 0.534. For measurement reliability, ICCs for intra-RR of R1 and R2 were 0.865 and 0.766, respectively. ICCs for inter-RR of R1 vs. R2, R2 vs. R3, and R1 vs. R3 were 0.865, 0.800, and 0.815, respectively. All ICCs were statistically significant (p≤0.001).Conclusion: The results of our study indicate that procedural reliability of biceps muscle size as assessed by BodyMetrix in elderly is moderate to good, and measurement reliability is good to excellent. Increasing the level of experience may further improve procedural reliability.
DOCUMENT
Moral food lab: Transforming the food system with crowd-sourced ethics
LINK