Ankle Foot Orthoses (AFOs) to promote walking ability are a common treatment in patients with neurological or muscular diseases. However, guidelines on the prescription of AFOs are currently based on a low level of evidence regarding their efficacy. Recent studies aiming to demonstrate the efficacy of wearing an AFO in respect to walking ability are not always conclusive. In this paper it is argued to recognize two levels of evidence related to the ICF levels. Activity level evidence expresses the gain in walking ability for the patient, while mechanical evidence expresses the correct functioning of the AFO. Used in combination for the purpose of evaluating the efficacy of orthotic treatment, a conjunct improvement at both levels reinforces the treatment algorithm that is used. Conversely, conflicting outcomes will challenge current treatment algorithms and the supposed working mechanism of the AFO. A treatment algorithm must use relevant information as an input, derived from measurements with a high precision. Its result will be a specific AFO that matches the patient's needs, specified by the mechanical characterization of the AFO footwear combination. It is concluded that research on the efficacy of AFOs should use parameters from two levels of evidence, to prove the efficacy of a treatment algorithm, i.e., how to prescribe a well-matched AFO.
DOCUMENT
Background: Impaired upper extremity function due to muscle paresis or paralysis has a major impact on independent living and quality of life (QoL). Assistive technology (AT) for upper extremity function (i.e. dynamic arm supports and robotic arms) can increase a client’s independence. Previous studies revealed that clients often use AT not to their full potential, due to suboptimal provision of these devices in usual care. Objective: To optimize the process of providing AT for impaired upper extremity function and to evaluate its (cost-)effectiveness compared with care as usual. Methods: Development of a protocol to guide the AT provision process in an optimized way according to generic Dutch guidelines; a quasi-experimental study with non-randomized, consecutive inclusion of a control group (n = 48) receiving care as usual and of an intervention group (optimized provision process) (n = 48); and a cost-effectiveness and cost-utility analysis from societal perspective will be performed. The primary outcome is clients’ satisfaction with the AT and related services, measured with the Quebec User Evaluation of Satisfaction with AT (Dutch version; D-QUEST). Secondary outcomes comprise complaints of the upper extremity, restrictions in activities, QoL, medical consumption and societal cost. Measurements are taken at baseline and at 3, 6 and 9 months follow-up.
DOCUMENT
Objective: The aim of this study was to obtain insight in specific elements influencing the use, non-use, satisfaction, and dissatisfaction of ankle foot orthoses (AFOs) and the presence of underexposed problems with respect to AFOs. Methods: A questionnaire was composed to obtain information from AFO users to investigate the variables associated with satisfaction and the relation between these variables. A specific feature of this study was the systematic analysis of the remarks made by the respondents about their AFO. Quantitative data analyses were used for analysing the satisfaction and qualitative analyses were used analysing the remarks of the respondents. A total of 211 users completed the questionnaire. Results: Our survey showed that 1 out of 15 AFOs were not used at all. About three quarters of the AFO users were satisfied and about one quarter was dissatisfied. Females and users living alone reported relatively high levels of dissatisfaction, especially in the field of dimensions, comfort, weight, safety and effectiveness. Dissatisfaction with respect to off-the-shelf AFOs for the item durability was higher than that for custom-made AFOs. In the delivery and maintenance process the items ‘maintenance’, ‘professionalism’ and ‘delivery follow-up’ were judged to be unsatisfactory. A large number of comments were made by the respondents to improve the device or process, mainly by the satisfied AFO users. These comments show that even satisfied users experience many problems and that a lot of problems of AFO users are ‘underexposed’. Conclusion: To improve user satisfaction, the user practice has to be identified as an important sub-process of the whole orthopaedic chain especially in the diagnosis and prescription, delivery tuning and maintenance, and evaluation phase.
LINK
Dissertatie met als onderwerp het ontwerp en evaluatie van de Hogere Beroepsopleidding Orthopedische Technologie in Nederland. In deze dissertatie wordt naast het ontwerp van de opleiding ingegaan op een vergelijking die is gemaakt met andere opleidingen op het gebied van hoger orthopedisch technologisch onderwijs in de wereld.
DOCUMENT
This paper explains the history of the graduate course in prosthetics and orthotics in the Netherlands. It also explains the schoolstystem in relationship towards vocational education and postgraduate education.
DOCUMENT
Assistive technology supports maintenance or improvement of an individual’s functioning and independence, though for people in need the access to assistive products is not always guaranteed. This paper presents a generic quality framework for assistive technology service delivery that can be used independent of the setting, context, legislative framework, or type of technology. Based on available literature and a series of discussions among the authors, a framework was developed. It consists of 7 general quality criteria and four indicators for each of these criteria. The criteria are: accessibility; competence; coordination; efficiency; flexibility; user centeredness, and infrastructure. This framework can be used at a micro level (processes around individual users), meso level (the service delivery scheme or programme) or at a macro level (the whole country). It aims to help identify in an easy way the main strengths and weaknesses of a system or process, and thus guide possible improvements. As a next step in the development of this quality framework the authors propose to organise a global consultancy process to obtain responses from stakeholders across the world and to plan a number of case studies in which the framework is applied to different service delivery systems and processes in different countries.
DOCUMENT
Assistive Technology (AT) is any technology that supports people with functional difficulties to perform their daily activities with less difficulty and/or obstruction, thus contributing to a more fulfilling life. This refers to people of all ages and to all kinds of functional limitations, either permanent or temporary. Assistive products can be traditional physical products, such as wheelchairs, eyeglasses, hearing aids, or prostheses, but they can also be special input devices, care robots, computers with accessible software, apps for smartphones, home automation solutions, virtual realities, etc. It is essential to understand that AT involves more than just familiar products, and that it also includes knowledge about the personalized selection of appropriate solutions, provisions, and services, as well as the training of all parties involved, the measurement of outcomes and impacts, awareness of ethical issues, etc.
DOCUMENT
BACKGROUND: Non-use of and dissatisfaction with ankle foot orthoses (AFOs) occurs frequently. The objective of this study is to gain insight in the conversation during the intake and examination phase, from the clients’ perspective, at two levels: 1) the attention for the activities and the context in which these activities take place, and 2) the quality of the conversation. METHODOLOGY: Semi-structured interviews were performed with 12 AFO users within a two-week period following intake and examination. In these interviews, and subsequent data analysis, extra attention was paid to the needs and wishes of the user, the desired activities and the environments in which these activities take place. RESULTS AND CONCLUSION: Activities and environments were seldom inquired about or discussed during the intake and examination phase. Also, activities were not placed in the context of their specific environment. As a result, profundity lacks. Consequently, orthotists based their designs on a ‘reduced reality’ because important and valuable contextual information that might benefit prescription and design of assistive devices was missed. A model is presented for mapping user activities and user environments in a systematic way. The term ‘user practices’ is introduced to emphasise the concept of activities within a specific environment.
LINK
This study evaluated the effect of specific postural support on motor behaviour of infants with and without minor neurological dysfunction (MND). The following questions were addressed: (1) Does application of supportive pillows affect the time during which the infant exhibits general movements (GMs) or specific movements? We defined specific movements as movements of specific parts of the body that occur in a specific, recognizable way. (2) Does application of pillows improve the quality of GMs or the repertoire of specific movements? (3) Is a pillow effect affected by neurological condition? Forty healthy, term infants (16 males, 24 females; mean age 3.04 m [SD 1.24 mo], range 1-5 mo) participated in the study. Twenty were neurologically normal and 20 had MND. Spontaneous motor behaviour in a supine position was video-recorded for 180 seconds in four conditions applied in random order: support by a pillow in (1) the shoulder region, (2) the pelvic region, (3) the shoulder and pelvic region, or (4) no pillow support. Two independent assessors evaluated the quality of GMs. The other movement parameters were assessed with a computer program. Duration of movements was determined and a variation index, consisting of the number of different specific movements in a condition, was calculated. The presence of pillows did not affect the time spent in GMs, specific movements, or GM quality in either group. In neurologically normal infants the shoulder pillow with or without pelvic pillow induced an increase in the variation index (p<0.01), whereas in the infants with MND, all pillow conditions resulted in a substantial increase of the movement repertoire (p<0.001). Our results demonstrate that specific postural support promotes variation in motor behaviour of young infants. This is particularly true for infants with MND.
DOCUMENT
In OE a more holistic approach in the design process is needed. This requires a shift of thinking from just the OD to overall goal setting: meeting the functional needs of the patients. This can only be achieved by upgrading the traditional orthopaedic engineering educational programs. Analysing the patient's problem, explicitly formulate OD requirements, the design, the manufacturing, tuning and evaluation must become seamlessly integrated parts of OE education.
DOCUMENT