There is a wide range of literature suggesting that implicit learning is more effective than explicit learning when acquiring motor skills. However, the acquisition of nursing skills in educational settings continues to rely heavily on detailed protocols and explicit instructions. This study aimed to examine the necessity for comprehensive protocols in the acquisition of nursing skills. In the context of bandaging techniques, three studies were conducted to investigate whether students who practiced with an instruction card containing minimal instructions (implicit group) performed comparably to the students who practiced with a protocol containing step-by-step instructions (explicit group). Study 1 was designed to determine whether both groups performed equally well in applying a bandage during training. Study 2 and 3 were designed to determine if both groups performed equally well during a retention and transfer (multitasking) test, administered after a series of three training sessions. In comparison with the explicit group, the implicit group demonstrated comparable performance with their practice attempts in Study 1 and performed equally well during the retention and transfer test in Study 2. Furthermore, several results from Study 3 indicated better performance of the implicit group. In conclusion, the use of protocols with explicit step-by-step instructions may not be essential for the acquisition of nursing skills. Instead, instructional methods that facilitate implicit learning may be preferable, as students in the implicit group demonstrated at least comparable performance in all studies and tended towards greater consistency when multitasking.
DOCUMENT
Objective: To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. Data sources: PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. Study selection: VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/ or responsiveness of cardiopulmonary exercise test protocols. Data extraction: Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Data synthesis: Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. Conclusion: No judgement could be made on which protocol is “best” for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.
DOCUMENT
Through a correspondence between two scholars, this paper explores and critiques various ways in which scholars working in ethnography and cultural analysis frame and construct their methodology and object of study. Through the close reading of theoretical accounts of methodology in ethnography and cultural analysis, we examine how these accounts construct the relationship between the scholar and her object of study.We read these scholarly practices as protocols, referring to the ways in which accounts of methodology may be understood as rules/guidelines by which scholars in these fields conduct research. Protocol etymologically refers to protos (first) and kolla (glue). Through the figure of the protocol, we delineate how scholars in ethnography and cultural analysis themselves become implicated in giving accounts of their research methodologies. Somatechnics presents a thoroughly multi-disciplinary scholarship on the body, providing a space for research that critically engages with the ethico-political implications of a wide range of practices and techniques. The term ‘somatechnics’ indicates an approach to corporeality which considers it as always already bound up with a variety of technologies, techniques and technics, thus enabling an examination of the lived experiences engendered within a given context, and the effects that technologies, technés and techniques have on embodiment, subjectivity and sociality.
MULTIFILE
Background. Barefoot plantar pressure measurements are routinely used in the risk evaluation for ulceration in diabetic patients with neuropathy. The aim was to compare three step-protocols commonly used for pressure assessment in these patients. Methods. Dynamic barefoot plantar pressures were measured in 14 diabetic neuropathic patients (vibration perception threshold >35 V) contacting a pressure platform on the first, second or third step after gait initiation. Ten repeated trials per step-protocol were collected. The 3-step protocol was regarded the reference protocol. Peak pressure, pressure-time integral and contact time were calculated for each of six anatomical foot regions. Intraclass correlation coefficients (ICC) were calculated to assess reliability in each protocol. Findings. Regional peak pressures and pressure-time integrals were not significantly different between protocols. Contact time was significantly different in the heel region between the 1-step and 3-step protocol only (P < 0.05). Intraclass correlation coefficients for the maximum 10 repeated trials were high (>0.87) and similar between protocols. Reliable estimates (ICC > 0.85) of peak pressure were achieved with three repeated trials in the 2-step protocol, and four in the other two; for pressure-time integral these numbers were 7 (1-step), 4 (2-step), and 5 trials (3-step). Interpretation. Barefoot plantar pressures in the diabetic neuropathic foot can be assessed in a reproducible manner with any of the step-protocols used. For this purpose, the 1-step and 2-step protocols prove to be valid methods. A 2-step protocol requires the least amount of repeated trials for obtaining reliable pressure data and may be recommended for assessment of these patients.
DOCUMENT
The effective operation of distributed energy sources relies significantly on the communication systems employed in microgrids. This article explores the fundamental communication requirements, structures, and protocols necessary to establish a secure connection in microgrids. This article examines the present difficulties facing, and progress in, smart microgrid communication technologies, including wired and wireless networks. Furthermore, it evaluates the incorporation of diverse security methods. This article showcases a case study that illustrates the implementation of a distributed cyber-security communication system in a microgrid setting. The study concludes by emphasizing the ongoing research endeavors and suggesting potential future research paths in the field of microgrid communications.
MULTIFILE
OBJECTIVES: To compare low contrast detail (LCD) detectability and radiation dose for routine paediatric chest X-ray (CXR) imaging protocols among various hospitals.METHODS: CDRAD 2.0 phantom and medical grade polymethyl methacrylate (PMMA) slabs were used to simulate the chest region of four different paediatric age groups. Radiographic acquisitions were undertaken on 17 X-ray machines located in eight hospitals using their existing CXR protocols. LCD detectability represented by image quality figure inverse (IQF inv) was measured physically using the CDRAD analyser software. Incident air kerma (IAK) measurements were obtained using a solid-state dosimeter. RESULTS: The range of IQF inv, between and within the hospitals, was 1.40-4.44 and 1.52-2.18, respectively for neonates; 0.96-4.73 and 2.33-4.73 for a 1-year old; 0.87-1.81 and 0.98-1.46 for a 5-year old and 0.90-2.39 and 1.27-2.39 for a 10-year old. The range of IAK, between and within the hospitals, was 8.56-52.62 μGy and 21.79-52.62 μGy, respectively for neonates; 5.44-82.82 μGy and 36.78-82.82 μGy for a 1-year old; 10.97-59.22 μGy and 11.75-52.94 μGy for a 5-year old and 13.97-100.77 μGy and 35.72-100.77 μGy for a 10-year old. CONCLUSIONS: Results show considerable variation, between and within hospitals, in the LCD detectability and IAK. Further radiation dose optimisation for the four paediatric age groups, especially in hospitals /X-ray rooms with low LCD detectability and high IAK, are required.
DOCUMENT
OBJECTIVE: To evaluate if using surface neuromuscular electrical stimulation (NMES) for paralyzed lower-limb muscles results in an increase in energy expenditure and if the number of activated muscles and duty cycle affect the potential increase.DESIGN: Cross-sectional study.RESULTS: Energy expenditure during all NMES protocols was significantly higher than the condition without NMES (1.2 ± 0.2 kcal/min), with the highest increase (+ 51%; +0.7 kcal/min, 95% CI: 0.3 - 1.2) for the protocol with more muscles activated and the duty cycle with a shorter rest period. A significant decrease in muscle contraction size during NMES was found with a longer stimulation time, more muscles activated or the duty cycle with a shorter rest period.CONCLUSION: Using NMES for paralyzed lower-limb muscles can significantly increase the energy expenditure compared to sitting without NMES with the highest increase for the protocol with more muscles activated and the duty cycle with a shorter rest period. Muscle fatigue occurred significantly with the more intense NMES protocols which might cause a lower energy expenditure in a longer protocol. Future studies should further optimize the NMES parameters and investigate the long-term effects of NMES on weight management in people with SCI.
DOCUMENT
Background and purpose: Automatic approaches are widely implemented to automate dose optimization in radiotherapy treatment planning. This study systematically investigates how to configure automatic planning in order to create the best possible plans. Materials and methods: Automatic plans were generated using protocol based automatic iterative optimization. Starting from a simple automation protocol which consisted of the constraints for targets and organs at risk (OAR), the performance of the automatic approach was evaluated in terms of target coverage, OAR sparing, conformity, beam complexity, and plan quality. More complex protocols were systematically explored to improve the quality of the automatic plans. The protocols could be improved by adding a dose goal on the outer 2 mm of the PTV, by setting goals on strategically chosen subparts of OARs, by adding goals for conformity, and by limiting the leaf motion. For prostate plans, development of an automated post-optimization procedure was required to achieve precise control over the dose distribution. Automatic and manually optimized plans were compared for 20 head and neck (H&N), 20 prostate, and 20 rectum cancer patients. Results: Based on simple automation protocols, the automatic optimizer was not always able to generate adequate treatment plans. For the improved final configurations for the three sites, the dose was lower in automatic plans compared to the manual plans in 12 out of 13 considered OARs. In blind tests, the automatic plans were preferred in 80% of cases. Conclusions: With adequate, advanced, protocols the automatic planning approach is able to create high-quality treatment plans.
DOCUMENT
This paper reveals how the automatising of protocols ignited a public conflict between Dutch banks and their Small and Medium-sized Enterprise (SME) clients in the years after the Global Financial Crisis. The bank’s “infirmary departments” for Financial Restructuring and Recovery (FR&R) were accused of (mal)treating SMEs. The conflict resulted in no formal regulatory or legal change despite public support. Instead, the banks created self-regulation to improve communication with SMEs, leading to shifts in governing FR&R for SMEs. This way, the banks mitigated significant negative symptoms of automation and solved the conflict with the SMEs while keeping FR&R and ongoing automation intact. The research uses an interdisciplinary analytical framework to understand national financial conflicts in a digitalised (business) world. It contributes to the theory of institutionalising values in discursive contests between action fields. The paper highlights the material and causes of normative conflicts of interest among critical actors in established public-private networks through discourse analysis and process tracing.
DOCUMENT
Aim: To investigate the effects of exercise on salivary concentrations of inflammatory markers by analyzing a panel of 25 inflammatory markers in subjects who had participated in bicycle ergometer tests varying in workload and hydration status. Methods: Fifteen healthy young men (20-35 years) had performed 4 different exercise protocols of 1 hour duration in a randomly assigned cross-over design, preceded by a rest protocol. Individual workloads depended on participant's pre-assessed individual maximum workload (Wmax): rest (protocol 1), 70% Wmax in hydrated (protocol 2) and dehydrated (protocol 3) state, 50% Wmax (protocol 4) and intermittent 85%/55% Wmax in 2 min blocks (protocol 5). Saliva samples were collected before (T0) and immediately after exercise (T1), and at several time points after exercise (2 hours (T3), 3 hours (T4), 6 hours (T5) and 24 hours (T6)). Secretory Leukocyte Protease Inhibitor (SLPI), Matrix Metallopeptidase-9 (MMP-9) and lactoferrin was analyzed using a commercial ELISA kit, a panel of 22 cytokines and chemokines were analyzed using a commercial multiplex immunoassay. Data was analyzed using a multilevel mixed linear model, with multiple test correction. Results: Among a panel of 25 inflammatory markers, SLPI concentrations were significantly elevated immediately after exercise in all protocols compared to rest and higher concentrations reflected the intensity of exercise and hydration status. MMP-9 showed a significant increase in the 70% Wmax dehydrated, 50% Wmax and intermittent protocols. Conclusions: Salivary concentrations of SLPI and MMP-9 seem associated with exercise intensity and hydration status and may offer non-invasive biomarkers to study (local) inflammatory responses to different exercise intensities in human studies. sa
DOCUMENT