Background: Previous studies found that 40-60% of the sarcoidosis patients suffer from small fiber neuropathy (SFN), substantially affecting quality of life. SFN is difficult to diagnose, as a gold standard is still lacking. The need for an easily administered screening instrument to identify sarcoidosis-associated SFN symptoms led to the development of the SFN Screening List (SFNSL). The usefulness of any questionnaire in clinical management and research trials depends on its interpretability. Obtaining a clinically relevant change score on a questionnaire requires that the smallest detectable change (SDC) and minimal important difference (MID) are known. Objectives: The aim of this study was to determine the SDC and MID for the SFNSL in patients with sarcoidosis. Methods: Patients with neurosarcoidosis and/or sarcoidosis-associated SFN symptoms (N=138) included in the online Dutch Neurosarcoidosis Registry participated in a prospective, longitudinal study. Anchor-based and distribution-based methods were used to estimate the MID and SDC, respectively. Results: The SFNSL was completed both at baseline and at 6-months’ follow-up by 89/138 patients. A marginal ROC curve (0.6) indicated cut-off values of 3.5 points, with 73% sensitivity and 49% specificity for change. The SDC was 11.8 points. Conclusions: The MID on the SFNSL is 3.5 points for a clinically relevant change over a 6-month period. The MID can be used in the follow-up and management of SFN-associated symptoms in patients with sarcoidosis, though with some caution as the SDC was found to be higher.
DOCUMENT
The wheelchair ergometer (Lode Esseda) can be used to monitor propulsion variables of wheelchair users, for example to evaluate wheelchair adaptations. In order to interpret the outcomes of the measurements and to support clinical decision making, it is important to distinguish real changes in propulsion technique and physiological outcomes from measurement errors.
DOCUMENT
OBJECTIVE: Ever since Engel's Biopsychosocial Model (1977) emotions, thoughts, beliefs and behaviors are accepted as important factors of health. The Brief Illness Perception Questionnaire (Brief IPQ) assesses these beliefs. Aim of this study was to cross-culturally adapt the Brief IPQ into the Brief IPQ Dutch Language Version (Brief IPQ-DLV), and to assess its face validity, content validity, reproducibility, and concurrent validity. METHODS: Beaton's guideline was used for cross-culturally adaptation. Face and content validity were assessed in 25 patients, 15 physiotherapists and 24 first-grade students. Reproducibility was established in 27 individuals with chronic obstructive pulmonary disease using Cohen's kappa coefficient (K(w)) and the Smallest Detectable Change (SDC). Concurrent validity was assessed in 163 patients visiting 11 different physical therapists. RESULTS: The Brief IPQ-DLV is well understood by patients, health care professionals and first-grade students. Reliability at 1 week for the dimensions Consequences, Concern and Emotional response K(w)>0.70, for the dimensions Personal control, Treatment control, Identity, K(w)<0.70. A time interval of 3 weeks, reliability coefficients were lower for almost all dimensions. SDC was between 2.45 and 3.37 points for individual measurement purposes and between 0.47 and 0.57 points for group evaluative measurement purposes. Concurrent validity showed significant correlations (P<.05) for four out of eight illness perceptions (IPs) dimensions. CONCLUSION: The face and content properties were found to be acceptable. The reproducibility and concurrent validity needs further investigated
DOCUMENT
Background Testing aerobic fitness in youth is important because of expected relationships with health. Objective The purpose of the study was to estimate the validity and reliability of the Shuttle Ride Test in youth who have spina bifida and use a wheelchair for mobility and sport. Design Ths study is a validity and reliability study. Methods The Shuttle Ride Test, Graded Wheelchair Propulsion Test, and skill-related fitness tests were administered to 33 participants for the validity study (age = 14.5 ± 3.1 y) and to 28 participants for the reliability study (age = 14.7 ± 3.3 y). Results No significant differences were found between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test for most cardiorespiratory responses. Correlations between the Graded Wheelchair Propulsion Test and the Shuttle Ride Test were moderate to high (r = .55–.97). The variance in peak oxygen uptake (VO2peak) could be predicted for 77% of the participants by height, number of shuttles completed, and weight, with large prediction intervals. High correlations were found between number of shuttles completed and skill-related fitness tests (CI = .73 to −.92). Intraclass correlation coefficients were high (.77–.98), with a smallest detectable change of 1.5 for number of shuttles completed and with coefficients of variation of 6.2% and 6.4% for absolute VO2peak and relative VO2peak, respectively. Conclusions When measuring VO2peak directly by using a mobile gas analysis system, the Shuttle Ride Test is highly valid for testing VO2peak in youth who have spina bifida and use a wheelchair for mobility and sport. The outcome measure of number of shuttles represents aerobic fitness and is also highly correlated with both anaerobic performance and agility. It is not possible to predict VO2peak accurately by using the number of shuttles completed. Moreover, the Shuttle Ride Test is highly reliable in youth with spina bifida, with a good smallest detectable change for the number of shuttles completed.
DOCUMENT
Objective: To determine content validity of the Muscle Power Sprint Test (MPST) and construct validity and reliability of the MPST, 10x5 Meter Sprint Test (10x5MST), slalom test and one stroke push test (1SPT) in wheelchair-using youth with spina bifida (SB). Design: Clinimetric study Setting: Rehabilitation centers, SB outpatient services, private practices Participants: A convenience sample of 53 children (5-19 years, 32 boys / 21 girls) with SB who use a manual wheelchair. Participants were recruited in the Netherlands through rehabilitation centers, SB outpatient services, pediatric physical therapists and the BOSK (Association of and by parents of children, adolescents and adults with a disability). Interventions: Not applicable. Main Outcome Measures: Construct validity of the the MPST was determined by comparing results with the arm-cranking Wingate Anaerobic test (WAnT) using paired t-tests and Pearson Correlation Coefficients, while content validity was assessed using time based criteria for anaerobic testing . Construct validity of the 10x5MST, slalom test and 1SPT was analyzed by hypothesis testing using Pearson Correlation Coefficients and Multiple Regression. For reliability, Intra Class Correlation coefficients (ICC) and smallest detectable changes (SDC) were calculated. Results: For the MPST, mean exercise time of four sprints was 28.1 sec. (±6.6 sec.). Correlations between the MPST and WAnT were high (r>0.72, p<0.01). Excellent correlations were found between the 10x5MST and slalom test (r=0.93, p<0.01), while correlations between the10x5MST or slalom test and MPST and 1SPT were moderate (r=-0.56- -0.70; r=0.56, p<0.01). The 1SPT was explained for 38% by wheelchair mass (Beta -0.489) and total upper muscle strength (Beta 0.420). All ICCs were excellent (ICC>0.95) but the SDCs varied widely. Conclusions: The MPST, 10x5MST and slalom test are valid and reliable tests in wheelchair-using youth with SB for measuring respectively anaerobic performance or agility. For the 1SPT, both validity and reliability are questionable.
DOCUMENT
Objective. There are no Dutch language disease-specific questionnaires for patients with patellofemoral pain syndrome available that could help Dutch physiotherapists to assess and monitor these symptoms and functional limitations. The aim of this study was to translate the original disease-specific Kujala Patellofemoral Score into Dutch and evaluate its reliability. Methods. The questionnaire was translated from English into Dutch in accordance with internationally recommended guidelines. Reliability was determined in 50 stable subjects with an interval of 1 week. The patient inclusion criteria were age between 14 and 60 years; knowledge of the Dutch language; and the presence of at least three of the following symptoms: pain while taking the stairs, pain when squatting, pain when running, pain when cycling, pain when sitting with knees flexed for a prolonged period, grinding of the patella and a positive clinical patella test. The internal consistency, test–retest reliability, measurement error and limits of agreement were calculated. Results. Internal consistency was 0.78 for the first assessment and 0.80 for the second assessment. The intraclass correlation coefficient (ICCagreement) between the first and second assessments was 0.98. The mean difference between the first and second measurements was 0.64, and standard deviation was 5.51. The standard error measurement was 3.9, and the smallest detectable change was 11. The Bland and Altman plot shows that the limits of agreement are 10.37 and 11.65. Conclusions. The results of the present study indicated that the test–retest reliability translated Dutch version of the Kujala Patellofemoral Score questionnaire is equivalent of the test– retest original English language version and has good internal consistency. Trial registration NTR (TC = 3258). Copyright © 2015 John Wiley & Sons, Ltd.
DOCUMENT
Objective: Despite the common occurrence of lower levels of physical activity and physical fitness in youth with spina bifida (SB) who use a wheelchair, there are very few tests available to measure and assess these levels. The purpose of this study was to determine reliability and the physiologic response of the 6-minute push test (6MPT) in youth with SB who self-propel a wheelchair. Methods: In this reliability and observational study, a sample of 53 youth with SB (5-19 years old; mean age = 13 years 7 months; 32 boys and 21 girls) who used a wheelchair performed 2 exercise tests: the 6MPT and shuttle ride test. Heart rate, minute ventilation, respiratory exchange ratio, and oxygen consumption were measured using a calibrated mobile gas analysis system and a heart rate monitor. For reliability, intraclass correlation coefficients (ICCs), SE of measurement, smallest detectable change for total covered distance, minute work, and heart rate were calculated. Physiologic response during the 6MPT was expressed as percentage of maximal values achieved during the shuttle ride test. Results: The ICCs for total distance and minute work were excellent (0.95 and 0.97, respectively), and the ICC for heart rate was good (0.81). The physiologic response during the 6MPT was 85% to 89% of maximal values, except for minute ventilation (70.6%). Conclusions: For most youth with SB who use a wheelchair for mobility or sports participation, the 6MPT is a reliable, functional performance test on a vigorous level of exercise. Impact: This is the first study to investigate physiologic response during the 6MPT in youth (with SB) who are wheelchair using. Clinicians can use the 6MPT to evaluate functional performance and help design effective exercise programs for youth with SB who are wheelchair using. Keywords: 6-minute push test; adolescent; disabled children; spinal diseases; wheelchairs.
DOCUMENT
OBJECTIVES: Amplitude-mode (A-mode) ultrasonography is a promising technique to monitor loss and recovery of skeletal muscle in patients with burns. However, its clinimetric properties are unknown. Therefore, we determined its feasibility, interrater, and intrarater reliability, and clinical utility.METHODS: Skeletal muscle thickness of upper arms and legs was assessed longitudinally in hospitalized adult patients with ≥ 5 % total body surface area (TBSA) burns, by pairs of two out of five raters. Feasibility was evaluated by % successful assessments, reliability by intra-class correlation coefficients (ICCs), and clinical utility by smallest detectable change (SDC).RESULTS: Thirty-four patients participated (77 % male; mean age 48 ± 17 y, median TBSA burned 12 % [IQR 7-19]). Images were acquired on 69 % of planned occasions, and 89 % of images could be analyzed. Overall interrater ICCs were ≥ 0.84 (for pairs: 0.63-0.99) and intrarater ICCs were ≥ 0.95 (for pairs: 0.45-0.99). The overall interrater SDC was ≤ 33 % of the measured mean (for pairs: 3-52 %), while intrarater SDC was ≤ 20 % (for pairs: 3-48 %). All five raters could measure legs with moderate to excellent reliability, whereas for arms some demonstrated poor reliability.CONCLUSION: A-mode ultrasonography assessment of skeletal muscle in patients with burns is feasible. However, reliability and clinical utility are rater-dependent; therefore we recommend assessments by the same rater.
DOCUMENT
In The Netherlands, the 4-Skills Scan is an instrument for physical education teachers to assess gross motor skills of elementary school children. Little is known about its reliability. Therefore, in this study the test–retest and inter-rater reliability was determined. Respectively, 624 and 557 Dutch 6- to 12-year-old children were analyzed for test re-test and inter-rater reliability. All tests took place within the school setting. The outcome measure was age-expected motor performance (in years). Results showed a small practice effect of .24 years for re-test sessions and assessment of motor skills was possible with acceptable precision (standard error of measurement = .67 years). Overall, intraclass correlation coefficient (ICC) was .93 (95% confidence interval: .92–.95) for test–retest reliability and .97 for inter-rater reliability. For the repeated measures, the smallest detectable change (SDC) was 1.84 and limits of agreement were –1.60 and 2.08 years. It can be concluded that the 4-Skills Scan is a reliable instrument to assess gross motor skills in elementary school children.
DOCUMENT
CC-BY-NC-NDSTUDY DESIGN:prospective cohort study.OBJECTIVE:To analyze responsiveness and minimal clinically important change (MCIC) of the US National Institutes of Health (NIH) minimal dataset for chronic low back pain (CLBP).SUMMARY OF BACKGROUND DATA:The NIH minimal dataset is a 40-item questionnaire developed to increase use of standardized definitions and measures for CLBP. Longitudinal validity of the total minimal dataset and the subscale Impact Stratification are unknown.METHODS:Total outcome scores on the NIH minimal dataset, Dutch Language Version, were calculated ranging from 0-100 points with higher scores representing worse functioning. Responsiveness and MCIC were determined with an anchor based method, calculating the area under the receiver operating characteristics (ROC) curve (AUC) and by determining the optimal cut-off point. Smallest detectable change (SDC) was calculated as a parameter of measurement error.RESULTS:In total 223 patients with CLBP were included. Mean total score on the NIH minimal dataset was 44 ± 14 points at baseline. The total outcome score was responsive to change with an AUC of 0.84. MCIC was 14 points with a sensitivity of 72% and specificity 82%, and SDC was 23 points. Mean total score on Impact Stratification (scale 8-50) was 34.4 ± 7.4 points at baseline, with an AUC of 0.91, an MCIC of 7.5 with a sensitivity 96% of and specificity of 78%, and an SDC of 14 points.CONCLUSION:The longitudinal validity of the NIH minimal dataset is adequate. An improvement of 14 points in total outcome score and 7.5 points in Impact Stratification can be interpreted as clinically important in individual patients. However, MCIC depends on baseline values and the method that is chosen to determine the optimal cut-off point. Furthermore, measurement error is larger than the MCIC. This means that individual change scores should be interpreted with caution.LEVEL OF EVIDENCE:4This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal
MULTIFILE