The seismic assessment of the out-of-plane (OOP) behaviour of unreinforced masonry (URM) buildings is essential since the OOP is one of the primary collapse mechanisms in URM buildings. It is influenced by several parameters, including the poor connections between structural elements, a weakness highlighted by post-earthquake observations. The paper presents a mechanical model designed to predict the contributions of various resisting mechanisms to the strength capacity of timber-joist connections in masonry cavity walls. The research presented in this paper considers two different failure modes: joist-wall interface failure, and OOP rocking behaviour of the URM walls. Consequently, two mechanical models are introduced to examine these failure modes in timber-joist connections within masonry cavity walls. One model focuses on the joist-wall interface failure, adopting a Coulomb friction model for joist-sliding further extended to incorporate the arching effect. The other model investigates the OOP rocking failure mode of walls. The combined mechanical model has been validated against the outcomes of an earlier experimental campaign conducted by the authors. The considered model can accurately predict the peak capacity of the joist connection and successfully defines the contribution of each mechanism in terms of resistance at failure.
The majority of houses in the Groningen gas field region, the largest in Europe, consist of unreinforced masonry material. Because of their particular characteristics (cavity walls of different material, large openings, limited bearing walls in one direction, etc.) these houses are exceptionally vulnerable to shallow induced earthquakes, frequently occurring in the region during the last decade. Raised by the damage incurred in the Groningen buildings due to induced earthquakes, the question whether the small and sometimes invisible plastic deformations prior to a major earthquake affect the overall final response becomes of high importance as its answer is associated with legal liability and consequences due to the damage-claim procedures employed in the region. This paper presents, for the first time, evidence of cumulative damage from available experimental and numerical data reported in the literature. Furthermore, the available modelling tools are scrutinized in terms of their pros and cons in modelling cumulative damage in masonry. Results of full-scale shake-table tests, cyclic wall tests, complex 3D nonlinear time-history analyses, single degree of freedom (SDOF) analyses and finally wall element analyses under periodic dynamic loading have been used for better explaining the phenomenon. It was concluded that a user intervention is needed for most of the SDOF modelling tools if cumulative damage is to be modelled. Furthermore, the results of the cumulative damage in SDOF models are sensitive to the degradation parameters, which require calibration against experimental data. The overall results of numerical models, such as SDOF residual displacement or floor lateral displacements, may be misleading in understanding the damage accumulation. On the other hand, detailed discrete-element modelling is found to be computationally expensive but more consistent in terms of providing insights in real damage accumulation.
Masonry structures comprise a significant portion of the historical building stock all over the world. Previousstudies have clearly pointed out that unreinforced masonry buildings are vulnerable against extreme loadingconditions, such as seismic actions. Therefore, strengthening is inevitable in most cases for historical masonry towithstand severe loads. In this paper, the efficiency of fabric reinforced cementitious matrix is investigatedexperimentally by using diagonal tension tests. Fourteen wallets with a nominal size of 750x750x235 mm wereproduced with using solid clay bricks and a low-strength mortar. The bricks were collected from the structuralwalls of an early-20th century building under restoration. The low-strength mortar represents the historicalmortar commonly used in similar historical brick masonry buildings located in Istanbul, Turkey. By testing thespecimens under monotonic diagonal compression loads, the effects of different types of plasters on the walletsurface, varying types of fibers used in textile reinforcement and anchors used for the connection between FRCMand substrate are investigated. Although the wallet samples have inherent shortcomings in representing overallcomponent response accurately, still the qualitative findings are enlightening the effectiveness of the FRCMsystem by increasing shear strength, stiffness (shear modulus) and dissipated energy of the masonry wallets. Thestrengthened specimens were failed due to shear sliding along a bed joint and/or by a stair-shaped separationwhile the refence specimens were failed due to the splitting of the specimen into two parts in the stair-steppedshape and a slipping through a bed joint.
LINK
Post-earthquake structural damage shows that wall collapse is one of the most common failure mechanisms in unreinforced masonry buildings. It is expected to be a critical issue also in Groningen, located in the northern part of the Netherlands, where human-induced seismicity has become an uprising problem in recent years. The majority of the existing buildings in that area are composed of unreinforced masonry; they were not designed to withstand earthquakes since the area has never been affected by tectonic earthquakes. They are characterised by vulnerable structural elements such as slender walls, large openings and cavity walls. Hence, the assessment of unreinforced masonry buildings in the Groningen province has become of high relevance. The abovementioned issue motivates engineering companies in the region to research seismic assessments of the existing structures. One of the biggest challenges is to be able to monitor structures during events in order to provide a quick post-earthquake assessment hence to obtain progressive damage on structures. The research published in the literature shows that crack detection can be a very powerful tool as an assessment technique. In order to ensure an adequate measurement, state-of-art technologies can be used for crack detection, such as special sensors or deep learning techniques for pixel-level crack segmentation on masonry surfaces. In this project, a new experiment will be run on an in-plane test setup to systematically propagate cracks to be able to detect cracks by new crack detection tools, namely digital crack sensor and vision-based crack detection. The validated product of the experiment will be tested on the monument of Fraeylemaborg.
In recent years, human-induced seismicity in the northern part of the Netherlands increased rendering the seismic response of unreinforced masonry (URM) structures critical. Majority of the existing buildings in the Netherlands are URM, which are not designed to withstand earthquakes. This issue motivates engineering and construction companies in the region to research on the seismic assessment of the existing structures.The companies working in the structural engineering field in the region were forced to adapt very quickly to the earthquake related problems, such as strengthening of existing buildings after earthquake. Such solutions are of prime importance for the Groningen region due to the extent of the earthquake problems and need for strengthening the houses. The research published in the literature show that the connections play an important role in seismic resistant of the houses. Fixing or improving the poor wall-to-wall or floor-to-wall connections may have a large positive impact on the overall seismic behaviour. Some strengthening solutions are already provided by SMEs, and an extensive experimental campaign was carried out at TU Delft on retrofitted connections. In this project, a new experiment will be run on a large shake-table, unique in the Netherlands, that can simulate earthquake vibrations. These tests, together with the previous experience, will complement the overall knowledge on the strengthening solutions and their performance under real-time actual earthquake vibrations.
In recent years, human-induced seismicity in the northern part of the Netherlands increased rendering the seismic response of unreinforced masonry (URM) structures critical. Majority of the existing buildings in the Netherlands are URM, which are not designed to withstand earthquakes. This issue motivates engineering and construction companies in the region to research on the seismic assessment of the existing structures. The companies working in the structural engineering field in the region were forced to adapt very quickly to the earthquake related problems, such as strengthening of existing buildings after earthquake. Such solutions are of prime importance for the Groningen region due to the extent of the earthquake problems and need for strengthening the houses. The research published in the literature show that the connections play an important role in seismic resistant of the houses. Fixing or improving the poor wall-to-wall or floor-to-wall connections may have a large positive impact on the overall seismic behaviour. Some strengthening solutions are already provided by SMEs, and an extensive experimental campaign was carried out at TU Delft on retrofitted connections. In this project, a new experiment will be run on a large shake-table, unique in the Netherlands, that can simulate earthquake vibrations. These tests, together with the previous experience, will complement the overall knowledge on the strengthening solutions and their performance under real-time actual earthquake vibrations.