Abstract: Since the first Oxford Survey of Childhood Cancer’s results were published, people have become more aware of the risks associated with prenatal exposure from diagnostic x rays. As a result, it has since been the subject of many studies. In this review, the results of recent epidemiological studies are summarized. The current international guidelines for diagnostic x-ray examinations were compared to the review. All epidemiological studies starting from 2007 and all relevant international guidelines were included. Apart from one study that involved rhabdomyosarcoma, no statistically significant associations were found between prenatal exposure to x rays and the development of cancer during 2007–2020. Most of the studies were constrained in their design due to too small a cohort or number of cases, minimal x-ray exposure, and/or data obtained from the exposed mothers instead of medical reports. In one of the studies, computed tomography exposure was also included, and this requires more and longer follow-up in successive studies. Most international guidelines are comparable, provide risk coefficients that are quite conservative, and discourage abdominal examinations of pregnant women.
DOCUMENT
Diagnostic reference levels (DRLs) for medical x-ray procedures are being implemented currently in the Netherlands. By order of the Dutch Healthcare Inspectorate, a survey has been conducted among 20 Dutch hospitals to investigate the level of implementation of the Dutch DRLs in current radiological practice. It turns out that hospitals are either well underway in implementing the DRLs or have already done so. However, the DRLs have usually not yet been incorporated in the QAsystem of the department nor in the treatment protocols. It was shown that the amount of radiation used, as far as it was indicated by the hospitals, usually remains below the DRLs. A procedure for comparing dose levels to the DRLs has been prescribed but is not Always followed in practice. This is especially difficult in the case of children, as most general hospitals receive few children. Health Phys. 108(4):462–464; 2015
DOCUMENT
Abstract—A survey was conducted among 20 Dutch hospitals about radiation protection for interventional fluoroscopy. This was a follow-up of a previous study in 2007 that led to several recommendations for radiation protection for interventional fluoroscopy. The results indicate that most recommendations have been followed. However, radiation-induced complications from interventional procedures are still often not recorded in the appropriate register. Furthermore, even though professionals with appropriate training in radiation protection are usually involved in interventional procedures, this often is not the case when these procedures are carried out outside the radiology department. Although this involvement is not required by Dutch law, it is recommended to have radiation protection professionals present more often at interventional procedures. Further improvements in radiation protection for interventional fluoroscopy may come from a comparison of dose-reducing practices among hospitals, the introduction of diagnostic reference levels for interventional procedures, and a more thorough form of screening and follow-up of patients
DOCUMENT
Abstract—A survey about radiation protection in pediatric radiology was conducted among 22 general and seven children’s hospitals in the Netherlands. Questions concerned, for example, child protocols used for CT, fluoroscopy and x-ray imaging, number of images and scans made, radiation doses and measures taken to reduce these, special tools used for children, and quality assurance issues. The answers received from 27 hospitals indicate that radiation protection practices differ considerably between general and children’s hospitals but also between the respective general and children’s hospitals. It is recommended that hospitals consult each other to come up with more uniform best practices. Few hospitals were able to supply doses that can be compared to the national Diagnostic Reference Levels (DRLs). The ones that could be compared exceeded the DRLs in one in five cases, which is more than was expected beforehand.
LINK
Introduction: The Netherlands does not have a national guideline for performing radiographic examinations on pregnant patients. Radiographic examination is a generic term for all examinations performed using ionizing radiation, including but not limited to radiographs, fluoroscopy and computed tomography. A pilot study amongst radiographers (Medical Radiation Technologists (MRTs)) showed that standardized practice of radiographic examinations on pregnant women is not evident between Radiology departments and that there is a need for a national guideline as the varying practice methods may lead to confusion and uncertainty amongst both patients and MRTs. Methods: Focus groups consisting of MRTs from several Radiology departments within the Netherlands were used to map ideas and requirements as to what should be included in the national guideline. Nine focus group sessions were organized with a total of 52 participants. Using a previous review (Wit, Fleur; Vroonland, Colinda; Bijwaard H. Pre-natal X-ray exposure and the risk of developing paediatric cancer; a systematic review of risk factors and a comparison of international guidelines. Health Physics 2021; 121 (3):225e233), the following key points were chosen as discussion topics for the focus group sessions: dose reduction, confirming pregnancy and risk communication. Results: Results showed that the participating MRTs did not agree on the use of lead aprons. That the national guideline should include standardized methods to adjust parameters to decrease radiation dose. Focus group participants find it difficult to ask a patient's pregnancy status, especially when dealing with relatively young and old (er) patients. When communicating the level of risk associated with a radiographic examination the participating MRTs would like to be able to use examples and comparisons, preferably by means of a multilingual website. Conclusion: A national guideline must include information on justification, available alternatives, dose reductions methods and confirmation of pregnancy requirements when fetal dose is a significant risk. Implications for practice: A national guideline ensures standardized practice can be implemented in Radiology departments, increasing clarity of the issues for both patients and MRTs.
DOCUMENT
Introduction: In the Netherlands, Diagnostic Reference Levels (DRLs) have not been based on a national survey as proposed by ICRP. Instead, local exposure data, expert judgment and the international scientific literature were used as sources. This study investigated whether the current DRLs are reasonable for Dutch radiological practice. Methods: A national project was set up, in which radiography students carried out dose measurements in hospitals supervised by medical physicists. The project ran from 2014 to 2017 and dose values were analysed for a trend over time. In the absence of such a trend, the joint yearly data sets were considered a single data set and were analysed together. In this way the national project mimicked a national survey. Results: For six out of eleven radiological procedures enough data was collected for further analysis. In the first step of the analysis no trend was found over time for any of these procedures. In the second step the joint analysis lead to suggestions for five new DRL values that are far below the current ones. The new DRLs are based on the 75 percentile values of the distributions of all dose data per procedure. Conclusion: The results show that the current DRLs are too high for five of the six procedures that have been analysed. For the other five procedures more data needs to be collected. Moreover, the mean weights of the patients are higher than expected. This introduces bias when these are not recorded and the mean weight is assumed to be 77 kg. Implications for practice: The current checking of doses for compliance with the DRLs needs to be changed. Both the procedure (regarding weights) and the values of the DRLs should be updated.
MULTIFILE
With this contribution, the results of the measurement campaign performed with a synchronously distributed antenna array testbed operating at the center frequency of 3.686 GHz are presented. For the first time, to the best of the authors’ knowledge, the electric field distribution induced by coherent downlink transmission was experimentally assessed in the proximity of the target receiver using a calibrated electromagnetic field probe. This allowed to quantify the actual observed electric field gain and the shape of the electric field enhancement region around the target received. It was found that 16 transmitting antenna elements enhance the root-mean-square electric field level by about a factor of two, in a 2.5λ neighborhood of the target receiver. In addition, a possible disruption of the propagation environment due to the probe movement was assessed through the real-time channel state information feedback.
DOCUMENT
Background: A new selective preventive spinal immobilization (PSI) protocol was introduced in the Netherlands. This may have led to an increase in non-immobilized spinal fractures (NISFs) and consequently adverse patient outcomes. Aim: A pilot study was conducted to describe the adverse patient outcomes in NISF of the PSI protocol change and assess the feasibility of a larger effect study. Methods: Retrospective comparative cohort pilot study including records of trauma patients with a presumed spinal injury who were presented at the emergency department of a level 2 trauma center by the emergency medical service (EMS). The pre-period 2013-2014 (strict PSI protocol), was compared to the post-period 2017-2018 (selective PSI protocol). Primary outcomes were the percentage of records with a NISF who had an adverse patient outcome such as neurological injuries and mortality before and after the protocol change. Secondary outcomes were the sample size calculation for a larger study and the feasibility of data collection. Results: 1,147 records were included; 442 pre-period, and 705 post-period. The NISF-prevalence was 10% (95% CI 7-16, n = 19) and 8% (95% CI 6-11, n = 33), respectively. In both periods, no neurological injuries or mortality due to NISF were found, by which calculating a sample size is impossible. Data collection showed to be feasible. Conclusions: No neurological injuries or mortality due to NISF were found in a strict and a selective PSI protocol. Therefore, a larger study is discouraged. Future studies should focus on which patients really profit from PSI and which patients do not.
DOCUMENT
Background: Knee and hip osteoarthritis (OA) among older adults account for substantial disability and extensive healthcare use. Effective pain coping strategies help to deal with OA. This study aims to determine the long-term relationship between pain coping style and the course of healthcare use in patients with knee and/or hip OA over 10 years. Methods: Baseline and 10-year follow-up data of 861 Dutch participants with early knee and/or hip OA from the Cohort Hip and Cohort Knee (CHECK) cohort were used. The amount of healthcare use (HCU) and pain coping style were measured. Generalized Estimating Equations were used, adjusted for relevant confounders. Results: At baseline, 86.5% of the patients had an active pain coping style. Having an active pain coping style was significantly (p = 0.022) associated with an increase of 16.5% (95% CI, 2.0–32.7) in the number of used healthcare services over 10 years. Conclusion: Patients with early knee and/or hip OA with an active pain coping style use significantly more different healthcare services over 10 years, as opposed to those with a passive pain coping style. Further research should focus on altered treatment (e.g., focus on self-management) in patients with an active coping style, to reduce HCU.
DOCUMENT
Abstract Background: Many countries in Europe have implemented managed competition and patient choice during the last decade. With the introduction of managed competition, health insurers also became an important stakeholder. They purchase services on behalf of their customers and are allowed to contract healthcare providers selectively. It has, therefore, become increasingly important to take one's insurance into account when choosing a provider. There is little evidence that patients make active choices in the way that policymakers assume they do. This research aims to investigate, firstly, the role of patients in choosing a healthcare provider at the point of referral, then the role of the GP and, finally, the influence of the health insurer/insurance policies within this process. Methods: We videotaped a series of everyday consultations between Dutch GPs and their patients during 2015 and 2016. In 117 of these consultations, with 28 GPs, the patient was referred to another healthcare provider. These consultations were coded by three observers using an observation protocol which assessed the role of the patient, GP, and the influence of the health insurer during the referral. Results: Patients were divided into three groups: patients with little or no input, patients with some input, and those with a lot of input. Just over half of the patients (56%) seemed to have some, or a lot of, input into the choice of a healthcare provider at the point of referral by their GP. In addition, in almost half of the consultations (47%), GPs inquired about their patients' preferences regarding a healthcare provider. Topics regarding the health insurance or insurance policy of a patient were rarely (14%) discussed at the point of referral. Conclusions: Just over half of the patients appear to have some, or a lot of, input into their choice of a healthcare provider at the point of referral by their GP. However, the remainder of the patients had little or no input. If more patient choice continues to be an important aim for policy makers, patients should be encouraged to actively choose the healthcare provider who best fits their needs and preferences.
DOCUMENT