De gymzaal is de allermooiste werkplek die er bestaat. Maar het kan in onze ogen nog mooier en beter. Op welke wijze kan technologie, in het bijzonder augmented reality, iets toevoegen aan het bewegingsonderwijs? Welke meerwaarde heeft het voor leerlingen en voor docenten? Aan welke toepassingen kun je denken? En wat zijn de randvoorwaarden?
The objective of this study was to introduce a new iterative method to reconstruct multi leaf collimator (MLC) positions based on low resolution ionization detector array measurements and to evaluate its error detection performance. The iterative reconstruction method consists of a fluence model, a detector model and an optimizer. Expected detector response was calculated using a radiotherapy treatment plan in combination with the fluence model and detector model. MLC leaf positions were reconstructed by minimizing differences between expected and measured detector response. The iterative reconstruction method was evaluated for an Elekta SLi with 10.0 mm MLC leafs in combination with the COMPASS system and the MatriXX Evolution (IBA Dosimetry) detector with a spacing of 7.62 mm. The detector was positioned in such a way that each leaf pair of the MLC was aligned with one row of ionization chambers. Known leaf displacements were introduced in various field geometries ranging from −10.0 mm to 10.0 mm. Error detection performance was tested for MLC leaf position dependency relative to the detector position, gantry angle dependency, monitor unit dependency, and for ten clinical intensity modulated radiotherapy (IMRT) treatment beams. For one clinical head and neck IMRT treatment beam, influence of the iterative reconstruction method on existing 3D dose reconstruction artifacts was evaluated. The described iterative reconstruction method was capable of individual MLC leaf position reconstruction with millimeter accuracy, independent of the relative detector position within the range of clinically applied MU's for IMRT. Dose reconstruction artifacts in a clinical IMRT treatment beam were considerably reduced as compared to the current dose verification procedure. The iterative reconstruction method allows high accuracy 3D dose verification by including actual MLC leaf positions reconstructed from low resolution 2D measurements.
LINK
OBJECTIVES: Patients with head and neck cancer (HNC) frequently encounter weight loss with multiple negative outcomes as a consequence. Adequate treatment is best achieved by early identification of patients at risk for critical weight loss. The objective of this study was to detect predictive factors for critical weight loss in patients with HNC receiving (chemo)radiotherapy ((C)RT).MATERIALS AND METHODS: In this cohort study, 910 patients with HNC were included receiving RT (±surgery/concurrent chemotherapy) with curative intent. Body weight was measured at the start and end of (C)RT. Logistic regression and classification and regression tree (CART) analyses were used to analyse predictive factors for critical weight loss (defined as >5%) during (C)RT. Possible predictors included gender, age, WHO performance status, tumour location, TNM classification, treatment modality, RT technique (three-dimensional conformal RT (3D-RT) vs intensity-modulated RT (IMRT)), total dose on the primary tumour and RT on the elective or macroscopic lymph nodes.RESULTS: At the end of (C)RT, mean weight loss was 5.1±4.9%. Fifty percent of patients had critical weight loss during (C)RT. The main predictors for critical weight loss during (C)RT by both logistic and CART analyses were RT on the lymph nodes, higher RT dose on the primary tumour, receiving 3D-RT instead of IMRT, and younger age.CONCLUSION: Critical weight loss during (C)RT was prevalent in half of HNC patients. To predict critical weight loss, a practical prediction tree for adequate nutritional advice was developed, including the risk factors RT to the neck, higher RT dose, 3D-RT, and younger age.